Page 331

Laser Rangefinders

I

Compass details An electronic fluxgate compass is used to obtain magnetic azimuth measurements. This compass works when the unit is tilted at up to 15° to the horizontal. The compass is rated at ±0.5° under laboratory conditions. In typical GIS data collection conditions, compass accuracy is typically around ±1–2°. In environments where magnetic interference is high (for example, in a vehicle), the compass can be considerably less accurate. Inclinometer details A fluid tilt sensor measures vertical angles, which are used to calculate the elevation of target points. The sensor is of a damped resistance fluid type, and can take measurements up to ±60°, accurate to 0.1°. Powering The Criterion 300 and 400 rangefinders are powered by a rechargeable 9.6 V NiCd battery. This battery takes approximately 12–14 hours to charge fully, and the rangefinder can be run for 7.5 hours or more on a fully-charged battery. Environmental limitations The Criterion rangefinder can be used at temperatures ranging between –30°C and +50°C (–22°F to +122°F). The laser casing is resistant to light rain (but not immersion) and dust. The Criterion rangefinder should be treated as precision optical equipment, and should be handled with care. It withstands reasonable drop shock, but alignment of the sighting scope should be checked after dropping. The rangefinder should always be transported in its hard carry-case.

TSC1 Asset Surveyor Operation Manual

309

Page 332

I

Laser Rangefinders

I.2.2

Accessories The Criterion 300 and 400 laser rangefinders can be used in four ways: •

As a handheld instrument

•

As a handheld instrument with a shoulder rest (stock)

•

With the optional yoke and unipod. The unipod includes a bracket onto which your datalogger may be clipped

•

With the optional yoke and a tripod

For most GIS data collection applications, the Criterion rangefinders are a little too heavy to be carried in one hand, and it is difficult to operate both a datalogger and handheld laser together. It can also be difficult to accurately sight on distant objects when supporting the laser by hand. The best compromise between portability and operability is usually the yoke/unipod.

I.2.3

Cabling for Use with the Asset Surveyor Software The Criterion 300 and 400 laser rangefinders can be purchased with an optional download cable. The download cable connects to the Criterion’s battery, and leads to a 7-pin connector. The 7-pin connector is cabled as shown in Table I.1. Table I.1

Cable connections

Criterion laser (5-pin Lemo)

(7-pin female D type)

5 Ground

5 Ground

4 Transmit

2 Receive

3 Receive

3 Transmit

The 7-pin connector is then plugged into the data cable (P/N 32287), which can be plugged directly into one of the ports on your TSC1 datalogger.

31 0

TSC1 Asset Surveyor Operation Manual

Page 333

Laser Rangefinders

I

Cabling for the Pro XRS receiver If you have a Pro XRS GPS receiver, connect the Criterion laser rangefinder to your receiver and datalogger as shown in Figure I.1.

Figure I.1

Criterion laser rangefinder cabling diagram for Pro XRS with TSC1

TSC1 Asset Surveyor Operation Manual

311

Page 334

I

Laser Rangefinders

Cabling for the Pro XR receiver If you have a Pro XR GPS receiver, connect the Criterion laser rangefinder to your receiver and datalogger as shown in Figure I.2.

Figure I.2

31 2

Criterion laser rangefinder cabling diagram for Pro XR with TSC1

TSC1 Asset Surveyor Operation Manual

Page 335

Laser Rangefinders

I

Cabling for the Pro XL receiver If you have a Pro XL GPS receiver, connect the Criterion laser rangefinder to your receiver and datalogger as shown in Figure I.3.

ESP

Figure I.3

Criterion laser rangefinder cabling diagram for Pro XL with TSC1

TSC1 Asset Surveyor Operation Manual

313

Page 336

I

Laser Rangefinders

I.2.4

Configuration for Use with the Asset Surveyor Software This section provides instructions for configuring the Criterion laser rangefinder itself. For more information on configuring the Asset Surveyor software to work with the Criterion laser rangefinder, see page 321. Entering Survey mode The Criterion 300 and 400 laser rangefinders both support a SURVEY mode of operation. In this mode they take range, azimuth and inclination measurements and can export these to your TSC1 datalogger. The following instructions describe the procedure to enter SURVEY mode. Note – Each time you turn the Criterion laser rangefinder on, you must re-enter SURVEY mode. 1.

Turn on the Criterion by pressing the POWER button (the bottom-left button on the back of the unit). If you have a Criterion 400, the main menu appears with the TREE entry visible:

TREE

If you have a Criterion 300, the main menu appears with the HEIGHT entry visible:

HEIGHT

31 4

TSC1 Asset Surveyor Operation Manual

Page 337

Laser Rangefinders

2.

I

Press the ↑ or ↓ arrow buttons until the SURVEY menu appears:

SURVEY

3.

Press the ENTER button to select the SURVEY menu. The first entry in the SURVEY menu is the BASIC MEASUREMENTS operation:

BASIC MEASUREMENTS 4.

Press ENTER again to select BASIC MEASUREMENTS. The following screen appears:

HD:-------.-- FT AZ:------.- DEG Your Criterion is now ready to be used in conjunction with a datalogger running the Asset Surveyor software, as described later in this chapter. Note – To return to the Criterion’s main menu, press the EXIT button repeatedly. The following sections - Specifying Units, Enabling Measurement Errors, Entering a Compass Offset, and Ensuring Accurate Heights - describe further configuration that may make the Criterion laser rangefinder easier to use and/or obtain better results. They may, however, be skipped if you want to immediately proceed to test the laser rangefinder with your Trimble GPS system.

TSC1 Asset Surveyor Operation Manual

315

Page 338

I

Laser Rangefinders

Specifying units The Criterion laser rangefinder lets you select the units in which distances and angles are displayed on its LCD. Note – The units displayed on the rangefinder's LCD do not affect the interpretation of data by the Asset Surveyor software. They simply let you view distances and angles in whatever units are most suitable for your application. You can change the Criterion’s units as follows: 1.

Return to the rangefinder’s main menu (by pressing the EXIT button repeatedly).

2.

Press the ↑ or ↓ arrow buttons until the SYSTEM configuration menu appears:

SYSTEM

3.

Press the ENTER button to select the SYSTEM menu. The first entry in the SYSTEM menu is the UNITS DEC.PRECISION category:

UNITS DEC. PRECISION 4.

Press ENTER again to select UNITS DEC. PRECISION. The following screen appears:

LINEAR UNITS: **ENG** METRIC The Criterion supports ENG (that is, English) and METRIC linear distance units (that is, feet or meters).

31 6

TSC1 Asset Surveyor Operation Manual

Page 339

Laser Rangefinders

5.

Use the ← or → arrow buttons to select ENG or METRIC and then press ENTER.

6.

Now press the ↓ arrow button to move on to the ANGULAR UNITS screen:

I

ANGULAR UNITS: **DEG** GRAD The Criterion supports DEG (that is, degrees) and GRAD (gradians) as angular units. 7.

Use the ← or → arrow buttons to select DEG or GRAD and then press ENTER.

8.

Press the EXIT button twice to return to the Criterion’s main menu.

Enabling measurement error messages Laser Technology Inc. recommends that new users of the Criterion enable measurement error messages. By default, these messages are disabled. Once measurement error messages are enabled, the rangefinder informs you whenever a measurement is invalid for some reason. Once you become experienced with the Criterion rangefinder, you can disable measurement errors if you want. To enable or change the measurement errors setting: 1.

Select the top-level SYSTEM menu from the Criterion’s main menu.

2.

Press the ↓ arrow button to scroll down to the MEASUREMENT ERRORS entry:

MEASUREMENT ERRORS

TSC1 Asset Surveyor Operation Manual

317

Page 340

I

Laser Rangefinders

3.

Press the ENTER button. The following screen is displayed:

DISPLAY ERRORS? **YES** NO 4.

Use the ← or → buttons to enable or disable the display of measurement error messages and then press ENTER.

5.

Press EXIT twice to return to the Criterion’s main menu.

When a measurement error is detected, the Criterion displays an error code on its LCD. The meaning of each code is indicated in Table I.2. Table I.2

Error messages

Message

Cause and actions

Error 1

The laser rangefinder failed to lock onto its target. Either the target was too close or it was out of range. Alternatively, the laser was not held steadily enough.

Error 2

The laser did not receive the minimum required pulses back to determine the range to the target. Hold the instrument steady and on target.

Error 3

The laser was moved off target while taking a reading. Keep the laser steady and on target.

Error 4

The tilt sensor is out of range. The maximum tilt angle permitted is ±60°.

Error 5

The fluxgate compass is outside its level range. When taking a compass reading, you must keep the instrument's tilt within a range of ±15°.

Press the CLEAR button to clear the error message.

31 8