Page 301

APPENDIX

F F

4600LS Surveyor In this chapter: ■

Introduction

■

Turning the receiver on

■

Turning the receiver off

■

Configuring the receiver to work with the Asset Surveyor software

■

Operational aspects specific to the 4600LS Surveyor

■

Cabling diagrams

■

Equipment list

Page 302

F

4600LS Surveyor

F.1

Introduction The 4600LS Surveyor is based around a high-performance single frequency GPS receiver. The 4600LS Surveyor provides differentially corrected C/A code positions accurate to better than one meter, on a second-by-second basis.

F.2

Turning the Receiver On Press the large green button on the 4600LS Surveyor control panel. After a second, the green LED above the light-bulb symbol turns on.

F.3

Turning the Receiver Off Hold down the large green button on the 4600LS Surveyor control panel for a few seconds. The three LEDs turn off.

F.4

Configuring the Receiver to Work with the Asset Surveyor Software No special configuration of the 4600LS Surveyor is required in order to use the Asset Surveyor software and 4600LS Surveyor together beyond the usual GPS rover options that you need to configure in the Asset Surveyor software. The minimum 4600LS Surveyor firmware should be version 1.10. The following section describes the settings required to obtain submeter accuracy from your 4600LS Surveyor.

28 0

TSC1 Asset Surveyor Operation Manual

Page 303

4600LS Surveyor

F.5

F

Operational Aspects Specific to the 4600LS Surveyor The following sections outline the operational aspects specific to the 4600LS Surveyor.

F.5.1

Submeter Accuracy To achieve accuracy with the 4600LS Surveyor of better than 1 meter (RMS) +2 ppm times the distance between the base station and the rover, you must use the following GPS rover options configuration settings in the Asset Surveyor software. Table F.1 lists the recommended settings. Table F.1

Recommended settings

Setting

Recommended value

Position mode

Overdetermined 3D or Manual 3D

PDOP mask

4.0 or less

SNR mask

6 or more

Elevation mask

15 degrees or more

You must also be using a base station that is logging or transmitting (in RTCM messages) synchronized measurements, and that is equipped with a Pro XR, Pro XRS, Pro XL, 4600LS, Site Surveyor 4400, GPS Total Station 4700, GPS Total Station 4800 or Series 4000 GPS receiver. Your roving receivers must be within 200 km of your base station. Finally, if you are performing differential correction by postprocessing your data, you must use the Differential Correction utility from the GPS Pathfinder Office software.

TSC1 Asset Surveyor Operation Manual

281

Page 304

F F.5.2

4600LS Surveyor

RTCM Input The 4600LS Surveyor receiver with TSC1 Asset Surveyor supports the RTCM version 2.0 format only.

F.5.3

Overdetermined Positions The 4600LS Surveyor receiver supports the computation of overdetermined 3D GPS positions.

F.5.4

Carrier Phase Mode The 4600LS Surveyor receiver can be operated in carrier phase mode. You enable carrier phase mode from GPS rover options / Logging options. The antenna name must be selected from the Type field in the Antenna options form, or the antenna part number selected from the Part number field.

F.5.5

Receiver Outputs The 4600LS Surveyor with Asset Surveyor does not transmit any receiver output information.

28 2

TSC1 Asset Surveyor Operation Manual

No reference (WMF)

Page 305

4600LS Surveyor F.5.6

F

Base Station Operation The 4600LS Surveyor receiver may be operated as a base station in two different ways.

F.5.7

1.

4600LS Surveyor with TSC1 datalogger. This is operated in the manner described in the TSC1 Asset Surveyor Software User Guide.

2.

4600LS Surveyor stand-alone base station. You can operate the 4600LS Surveyor as a stand-alone base station providing that: – you use the Differential Correction utility in the GPS Pathfinder Office software when differentially correcting any rover files using this base data.

– you set the Elevation mask on the rover units to 20° (the default elevation mask on the 4600LS is 15°).

External Sensors You can use external sensors and laser rangefinders with the 4600LS Surveyor receiver and TSC1 datalogger.

TSC1 Asset Surveyor Operation Manual

No reference (WMF)

283

Page 306

F

F.6

4600LS Surveyor

Cabling Diagrams To use the Asset Surveyor software with a 4600LS Surveyor receiver, connect the system as shown in Figure F.1, Figure F.2, and Figure F.3.

Figure F.1

28 4

4600LS Surveyor with TSC1 Asset Surveyor

TSC1 Asset Surveyor Operation Manual smrr.wmf

Page 307

4600LS Surveyor

Figure F.2

F

Two-port 4600LS Surveyor receiver with camcorder battery and TSC1 Asset Surveyor

Note – The TSC1 datalogger always connects to Port 1 on the 4600LS Surveyor receiver.

TSC1 Asset Surveyor Operation Manual sicr.wmf

285

Page 308

F

4600LS Surveyor

Radio

Figure F.3

28 6

4600LS Surveyor RTCM input configuration with radio, TSC1, and external power

TSC1 Asset Surveyor Operation Manual

Page 309

4600LS Surveyor

F.7

F

Equipment List Table F.2 lists the equipment that you can use in the field when operating a 4600LS Surveyor receiver in conjunction with the Asset Surveyor software running on your TSC1 datalogger. Table F.2

Equipment list

Part name

Part number

8-Channel 4600LS Surveyor (Single Port)

28615-10

12-Channel 4600LS Surveyor (Single Port)

28615-15

8-Channel 4600LS Surveyor (Dual Port)

28615-20

12-Channel 4600LS Surveyor (Dual Port)

28615-25

TSC1 to 4600LS Y-Cable

32958

Radio to 4600LS Y-Cable

30119

Quick Release Adapter

19847

Quick Release

19493

Camcorder Battery Pouch Kit

28613-00

TSC1 Asset Surveyor Operation Manual

287

Page 310

F

28 8

4600LS Surveyor