Page 101

PLACER.BK : Placer 6 Page 15 Monday, February 24, 1997 9:30 AM

The Placer GPS 455 and 455DR

Vehicle Odometer Information Vehicle odometers generally fall into one of three categories: digital, analog or mechanical. Following is a description of each type. Digital Signals. Square wave signals usually from 0 to the vehicles positive battery voltage (12 Volts). The pulse frequency is proportional to the vehicle speed. Possible problem: The Placer 455 DR requires a minimum of 2000 pulses per mile (ppm). Solution: This requires the installation of a Hall Effect Transducer in the odometer cable line by a speedometer service technician. The vehicle’s standard odometer signal will not be used. Analog Signals. Approximately sinusoidal or triangular signals where both the frequency and amplitude increase proportionally to the vehicle speed. Possible problem: At (very) low speeds the analog signal amplitude is too small and the Placer 455 counts zero pulses and treats the vehicle as if it is stopped. Solution: Use a signal conditioner to convert the analog signal into a square wave provided the underlying analog signal is capable of outputting at least 2000 ppm. Then the digital signal description above applies. If the pulse rate is below the required 2000 ppm value, this requires the installation of a Hall Effect Transducer or contact Trimble for adjustment instructions. Mechanical Odometer. This requires the installation of a Hall Effect Transducer in the odometer cable line by a speedometer service technician. This creates a digital signal as described above.

Signal conditioners and Hall Effect transducers can be obtained from taxi supply distributors or odometer repair shops.

6-15

Page 102

PLACER.BK : Placer 6 Page 16 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Calibrating the Placer GPS 455DR The odometer and gyroscope sensors used in the Placer 455DR system must be calibrated after installation for the system to function correctly. The calibration values are stored in the Placer’s battery backed memory for use in the normal daily operation of the system. Please read this section thoroughly prior to running the calibration program. During the calibration procedure, you will be monitoring your vehicle for the odometer pulse rate and driving specific measured distances. In general, you will do the following: ■

Check the odometer for pulses and pulse rate consistency at slow, medium, and fast speeds.

■

Drive a known distance (usually 1/2 or 1 mile) and measuring the number of pulses per mile from the vehicles odometer.

■

Drive 3 to 5 circles, first turning right, then turning left.

Trimble provides a DOS compatible calibration program, PLCRINIT.EXE, to assist you in the calibration procedure. This program will guide you through each step of the process. After the mechanical installation of the Placer 455 DR is complete, connect a (portable) IBM compatible PC to the Placer using the MDT side of the communications cable. Configure the PC as described in Table 6-4.

6-16

Page 103

PLACER.BK : Placer 6 Page 17 Monday, February 24, 1997 9:30 AM

The Placer GPS 455 and 455DR

Table 6-4. Portable PC Requirements for Calibration Item

Requirement

Operating System

MS DOS V6.1 or later, Windows V3.1 or later, or Windows 95.

RS-232 Port

9600 baud, 8, none, 1 (default)

NOTE: For MS DOS/PC DOS operating systems, both PLCRINIT.EXE and CHAT.INI must be copied onto the hard disk into the same sub-directory. Select the sub-directory before executing PLCRINIT.EXE. For Windows 3.1 and Windows 95, select a DOS box to run PLCRINIT.EXE. For proper operation, zoom the window to the full size of the screen.

6-17

Page 104

PLACER.BK : Placer 6 Page 18 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Conventions Used in the following Sections The calibration instructions provided in this chapter will appear in helvetica bold type. Brackets (<>) are used to indicate characters typed by the user. Conventions are used as follows: ■

<cr> is the indicator for the enter key or carriage return key

■

<sp> indicates the space bar

■

<esc> is the escape key

Responses by the calibration software that will vary in different installations are shown in italics. For both these entries d is used to indicate any digit and a indicates any letter. When the actual letters “d” or “a” are used, they will appear in double quotes.

Installing the Configuration Program PLCRINIT.EXE can be run directly from the provided diskette or a local copy created on your PC. 1.

At the DOS prompt, select the directory or drive. Then, type PLCRINIT then <cr>.

2.

Type “d” <cr> to begin the calibration process. You should see the main calibration menu illustrated below. PLCRINIT Vx.xx, Use <esc> to Quit; Use ? for Help Screen Sensor Calibration Menu 1.) Start Gyro Scale Factor Cal. 2.) Display Raw Odometer Pulses 3.) Set Sensor Data Enter choice: d <cr>

6-18

Page 105

PLACER.BK : Placer 6 Page 19 Monday, February 24, 1997 9:30 AM

The Placer GPS 455 and 455DR

Calibrating the Odometer The PLCRINIT program divides the screen into two windows. The upper window provides a series of menus and choices for the calibration procedure. The data scrolling in the lower window is not relevant to the configuration process. It is recommended that you first calibrate the odometer, and then start the gyroscope scale factor calculation. 1.

Type 2 <cr> in the main calibration menu to display the following screen. ********** Odometer Raw Pulse Measurement *********** Odometer raw pulse measurement started Press any key to stop calibration. ODOM PULSES = dddd

Conduct the following vehicle tests to begin the calibration procedure. 2.

Verify that there are no pulses while the vehicle is stopped. This test should run for about 60 seconds.

3.

Drive at a slow speed (below 5 m.p.h.). There should be a consistent nonzero pulse rate.

4.

Drive at about 25 m.p.h. Again, there should be a consistent pulse rate greater than that observed in Step 3.

5.

Drive at 55 m.p.h. The pulse rate should be greater than that in Step 4.

NOTE: At any time during this process the odometer counter can be reset to zero by the following sequence of keystrokes: <sp>, N, “d”, then 2. This will briefly enter the value in the Odometer screen in Step 7 and exit back to the start of the calibration.

6-19

Page 106

PLACER.BK : Placer 6 Page 20 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

The final odometer measurement is the number of pulses per mile (PPM). 6.

Reset the odometer counter to 0 as above (<sp>, N, “d”, then 2).

7.

Stop, press <sp> and you will see the first four lines in the following screen. Note the number of pulses on the installation checklist. ********** Odometer Raw Pulse Measurement *********** Odometer raw pulse measurement stopped. ODOM PULSES = dddd Enter new odometer pulses per mile value? (Y/N) YES

8.

Enter Y to “enter new odometer pulse per mile value“? ********** Odometer Raw Pulse Measurement *********** Set Odometer Data Change odometer type?: (Y/N) YES Odometer type: (<space> cycle, <CR> select, ^Z abort)

9.

6-20

From here you have the option to change the odometer type. The default is digital and if no change is required (based on the section Connecting the Vehicle Odometer) the response to “Change odometer type?” should be N. For analog odometers respond Y.

Page 107

PLACER.BK : Placer 6 Page 21 Monday, February 24, 1997 9:30 AM

The Placer GPS 455 and 455DR

10. The next option allows you to cycle between “Odometer type: Digital (1)” and “Odometer type: Analog (2)” by typing <sp>. Select by typing <cr> or use control z (^Z) if you entered this menu line accidentally. ********** Odometer Raw Pulse Measurement *********** Change odometer scale factor? : (Y/N) YES Enter odometer sf: dddd

11. The next section allows you to enter the odometer scale factor in ppm based on the measured mile results from screen 2. Respond Y to “Change odometer scale factor?”, enter the number of pulses per mile per mile as determined in Step 6, then type <cr>. ********** Odometer Raw Pulse Measurement *********** Set new odometer values to Odometer type: <Digital odometer, Analog Odometer, unchanged> Odometer scale factor: < w/ dddd.000000 scale factor, unchanged> (Y/N)

12. The confirmation message at the bottom of the screen appears. If the values are correct type Y. The odometer calibration procedure is complete. NOTE: The entry process can be repeated without redoing the ppm measurement by selecting 3) “Set Sensor Data” from the screen 1 menu.

6-21

Page 108

PLACER.BK : Placer 6 Page 22 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Calibrating the Gyroscope Having completed the odometer calibration, the next step is to calibrate the gyroscope. Completing the odometer calibration prior to the gyroscope calibration is important because the Placer 455 system relies on the odometer to detect when the vehicle is in motion during the gyroscope calibration. After completing the odometer calibration procedure, return to the main Calibration menu. 1.

Type “d” to return to the main Calibration menu. PLCRINIT Vx.xx, Use <esc> to Quit; Use ? for Help Screen Sensor Calibration Menu 1.) Start Gyro Scale Factor Cal. 2.) Display Raw Odometer Pulses 3.) Set Sensor Data Enter choice: d <cr>

2.

Type 1 <cr> to select gyroscope calibration. ***************** Gyro Scale Factor Calibration ***************** The odometer installation/calibration should be complete before starting the gyro calibration Are you ready to calibrate the gyro? (Y/N) YES

3.

6-22

Type Y to confirm that you want to calibrate the gyroscope.

Page 109

PLACER.BK : Placer 6 Page 23 Monday, February 24, 1997 9:30 AM

The Placer GPS 455 and 455DR

The next screen you will see prompts you to press any key when you are ready to begin the calibration procedure. It is usually easiest to line up the vehicle with a line in a parking lot or an equivalent indicator of the vehicles direction. ***************** Gyro Scale Factor Calibration ***************** Gyro scale factor calibration begins with clockwise (RIGHT) turns. Prepare to make right turns. Press ANY KEY to begin calibration.

4.

Press any key or type <sp>to access the following screen. ***************** Gyro Scale Factor Calibration ***************** Right Scale Factor Cal Started. Press ANY KEY to stop calibration. DR Sensor Calibration Data: Calibration heading: ddd.ddd

5.

Drive 3 to 5 circles clockwise returning to the original vehicle direction at completion. Each circle should be completed under about 20 seconds at reasonable constant speed. The heading displayed should be about 360 degrees for each turn +/- 10%.

6.

Once stopped type <sp> to end the calibration. The following screen is displayed. ***************** Gyro Scale Factor Calibration ***************** Prepare to make left turns. Press ANY KEY to begin calibration.

7.

Move the vehicle if necessary to the position for completing counterclockwise turns. You should perform the calibration in a similar fashion to the clockwise one, including the same number of turns.

6-23

Page 110

PLACER.BK : Placer 6 Page 24 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

8.

Type <sp> to begin calibration. ***************** Gyro Scale Factor Calibration ***************** Left Scale Factor Cal Started. Press ANY KEY to stop calibration. DR Sensor Calibration Data: Calibration heading: -ddd.ddd

9.

As you drive, notice that the counterclockwise turns are indicated by a negative calibration heading.

10. Type <sp> to end calibration. ***************** Gyro Scale Factor Calibration ***************** GYRO BIAS RATE (FYI) : sd.dddddd GYRO LEFT SCALE FACTOR : d.dddddd GYRO RIGHT SCALE FACTOR : d.dddddd 1) Save these values. 2) Use results in BBRAM. 3) Use default values. Enter choice:

The bias rate is not used in the calibration but should be within the range of -10 to +10 degrees per second for correctly functioning gyroscopes. The left and right scale factors should lie in the range from 0.9 to 1.1 and be close to each other in value. If you feel that the calibration was performed accurately the scale factors should be saved in battery backed-up memory on the Placer (BBRAM). These values will then be used in all future operation of the Placer 455DR. The gyroscope calibration procedure is complete.

6-24