Page 91
PLACER.BK : Placer 6 Page 5 Monday, February 24, 1997 9:30 AM
The Placer GPS 455 and 455DR
The Placer GPS 455DR guarantees continuous position reporting even during periods when all GPS signals are obscured. In many city driving situations, tall buildings and narrow streets obscure most or all of the GPS signals. These urban canyons can also degrade visible GPS signals by reflections or multipath. These conditions fall substantially outside the U.S. Government specifications for the SPS GPS performance and often create position errors several times the 100 meters SPS specification. Under urban canyon conditions, the Placer 455DR is able to reject the degraded GPS signals and produce position accuracy of 35 meters 95% 2D RMS compared to the 100 meters for standard GPS with SA. When the Placer GPS 455DR is enhanced with the DGPS option using RTCM corrections less than 30 seconds old, position accuracy is improved to about 15 meters in urban canyon driving and about 5 meters in open areas with good GPS visibility. Placer GPS 455DR Calibration
For optimal performance, the Placer GPS 455DR must be calibrated at installation. Trimble provides the DOS compatible program PLCRINIT.EXE for this purpose. Calibration is usually performed by connecting a laptop or portable PC to the Placer’s mobile data terminal (MDT) port, running the PLCRINIT program and following a series of menu prompts. The odometer installation is checked by driving at several speeds and observing consistent pulses from the program, then calibrated by driving a known distance and inputting the number of pulses per mile via the calibration menus. The gyroscope is calibrated by first driving clockwise for several complete circles, and then counter-clockwise for the same number of circles. Full details of the calibration are included later in this chapter. NOTE: The functional specifications for the Placer 455DR and the gyroscope (heading sensor) are provided in Chapter 2 of this manual.
6-5
Page 92
PLACER.BK : Placer 6 Page 6 Monday, February 24, 1997 9:30 AM
PLACER GPS INSTALLATION AND OPERATOR’S MANUAL
Installation Instructions for installing and configuring the Placer GPS 455 and 455DR are provided in this chapter. Following the provided instructions will eliminate many of the common causes of system failures. Chapter 4 describes the installation of the Placer and the antenna that are common to all Placer GPS systems.
Inventory Upon receipt of the Placer GPS 455, verify that you have the following components. The interconnection of the Placer GPS 455 components is illustrated in Figure 6-2. Table 6-1. Placer GPS Inventory Component
Part Number
Placer GPS 450 receiver processing unit
30837-10 or 30837-20
Placer GPS 455 MAP27 CPDP TAIP DR/MAP27 DR/CPDP DR/TAIP
30376-10 30376-20 30376-90 31601-00 31602-00 32343-00
DR Sensor Cable
30315
Gyroscope and Upgrade Kit (heading sensor)
31321-00
Antennas:
6-6
Magnetic Mount Antenna and cable
28367-00 or
Hard Mount Antenna and Cable
31192-00 or
Page 93
PLACER.BK : Placer 6 Page 7 Monday, February 24, 1997 9:30 AM
The Placer GPS 455 and 455DR
Component
Part Number
Hard Mount Antenna Cable (used with HMA option) right angle TNC straight TNC
31193 or 30893
Optional Accessories: Communications cable
19309-00
Digital I/O cable
30512
Power Cable
30514
6-7
Page 94
PLACER.BK : Placer 6 Page 8 Monday, February 24, 1997 9:30 AM
PLACER GPS INSTALLATION AND OPERATOR’S MANUAL
The Communications Cable The communications interface cable supports RS-232 bi-directional communication between the Placer and the mobile data terminal (MDT) and between the Placer and the RTCM port. The communications cable is terminated at the Placer end with a single female DB9 connector which mates to the MDT/RTCM connector on the Placer. The other end of the cable is split, providing two DB9 connectors. The first connector, labeled MDT, connects to the serial port of a PC or an MDT to send and receive messages in the selected protocol. The second serial port on the Communications cable labeled RTCM is used for the serial input of RTCM SC-104 data to the Placer 455 and Placer 455DR to receive differential corrections Figure 6-3. The Communications Cable MDT Port
RTCM Port
6-8
Page 95
PLACER.BK : Placer 6 Page 9 Monday, February 24, 1997 9:30 AM
The Placer GPS 455 and 455DR
The Interface Connections The Placer GPS 455 has four interface ports: Radio/Modem, MDT/RTCM, Digital I/O, and Heading Sensor. The Radio/Modem port, the Digital I/O port and the MDT/RTCM port are described in Chapter 4 of this manual. The four receiver hardware connectors are specified for use as described inTable 6-2. The interface protocols for each port are also listed in this table. Table 6-2. Interface Connection Placer Port
Connection Type
Communication Interface
Radio/Modem
DB9 F DTE connector
MAP27, CPDP radio protocols (TAIP message format)
MDT/RTCM
DB9 F DCE connector (Pins 2, 3, 5, 7, 8 (see Table 4-4)
(MDT) TAIP message format. Also unit configuration.
DB9 F DCE connector (Pins 1, 4, 5, 6, 9)
(RTCM) RTCM CS-104 standard differential corrections format.
Digital I/O
DB9 F DCE connector
Alarms/event markers/pps output
Heading Sensor
DB9 F DCE connector
Gyroscope and vehicle connections for odometer and backup light
6-9
Page 96
PLACER.BK : Placer 6 Page 10 Monday, February 24, 1997 9:30 AM
PLACER GPS INSTALLATION AND OPERATOR’S MANUAL
Installing the Heading Sensor The heading sensor (gyroscope) must be rigidly mounted so the sensors axes is vertical. The heading sensor mounting bracket provides for both side and bottom mounting options. NOTE: It is critical to Placer 455 performance that the heading sensor be mounted within 5°of vertical.
Figure 6-4. Heading Sensor
When mounting the heading sensor in the vehicle, avoid the following hazards:
6-10
■
Exposure to bumping (the cargo area)
■
Exposure to strong magnetic fields (audio equipment or the magneticalmounted antenna)
■
Excessive heat (exhaust manifolds) or excessive cold (refrigeration units or air conditioning ducts)
■
High vibration areas (Engine compartment, transmission)
■
Corrosive fluids and gasses
■
Exposure to water
Page 97
PLACER.BK : Placer 6 Page 11 Monday, February 24, 1997 9:30 AM
The Placer GPS 455 and 455DR
Connecting the Heading Sensor The heading sensor connects to the Placer through the Heading Sensor cable (see Figure 6-5). Choose a location for the heading sensor that allows for convenient connection to the Placer using the supplied DR sensor cable. Figure 6-5. Heading Sensor Cable Odometer 0 (red) GND (blk) Odometer 1 (red) GND (blk) GND (blk) +5V (red) Backup (wht)
1.
m
} ODO "0" } ODO "1" } 2 conductor zip cable
Connect the heading sensor to the Placer through the female 9-pin connector on the DR Sensor Cable. The connector labeled Heading Sensor connects to the heading sensor; the connector labeled Sensors connects to the Placer.
WARNING: The heading sensor contains mechanical shock sensitive components. Do not drop this equipment.
6-11
Page 98
PLACER.BK : Placer 6 Page 12 Monday, February 24, 1997 9:30 AM
PLACER GPS INSTALLATION AND OPERATOR’S MANUAL
Connecting the Backup Signal The Placer 455DR uses the signal from the vehicle’s backup light to indicate direction of travel. This is required because odometer signals are the same when driving forward or backward at the same speed.
6-12
1.
Connect the white wire from the DR Sensor Cable to the positive side of your vehicle’s backup light.
2.
Do not connect the black backup ground; leave the wire unterminated.
Page 99
PLACER.BK : Placer 6 Page 13 Monday, February 24, 1997 9:30 AM
The Placer GPS 455 and 455DR
Connecting the Vehicle Odometer Prior to connecting the heading sensor to your vehicle, study the vehicle wiring diagram to locate the odometer/speed signal. If possible, examine the odometer signal using an oscilloscope to determine if the signal type is analog or digital. If examining the signal directly is not feasible, it is usually possible to determine if the signal is digital or analog by attempting the odometer calibration procedure described later in this chapter. First try the default digital setting.
Connecting a Digital Odometer The default odometer type for the Placer 455 DR is digital. If when running the odometer calibration program no pulses are detected at low speeds but are seen at high speeds, then the setting may need to be changed to analog using the PCLRINIT.EXE configuration program described later in this chapter. 1.
Connect the red (signal) wire from the cable labeled “ODO 0” on the DR Sensor Cable to the vehicle odometer signal.
2.
Do not connect the black wire labeled Ground. The “ODO 1” cable is not used and can be trimmed as is convenient.
Table 6-3. Analog and Digital Signals Threshold Below Which Pulses Cannot be Detected Period Between Pulses or Peaks
Digital Peak Amputude
Analog Peak Amputude
2 secs
1.6 V
.21 V
1 secs
1.5 V
.21 V
0.1 sec
1.2 V
.11 V
0.01 sec
1.2 V
.11 V
1 milisec
1.3 V
.14 V
.2 milisec
2.7 V
.38 V
6-13
Page 100
PLACER.BK : Placer 6 Page 14 Monday, February 24, 1997 9:30 AM
PLACER GPS INSTALLATION AND OPERATOR’S MANUAL
Figure 6-6. Analog Signal
6-14