Page 111

PLACER.BK : Placer 6 Page 25 Monday, February 24, 1997 9:30 AM

The Placer GPS 455 and 455DR

Modifying the DR Sensor Values If during the calibration procedure you determine that your odometer is digital rather than analog, the Sensor Calibration Data screen provides the most efficient method for changing the odometer type during installation. The gyroscope will require that you enter both the left and right scale factors. Any combination of the three items: odometer type, odometer scale factor, and gyroscope scale factors can be changed independently. 1.

Type 3 <cr> at the main calibration menu. Then, follow the prompts on the screen to modify the DR sensor values. ******************** Sensor Calibration Data ******************** Set Sensor Data Change odometer type?: (Y/N) YES Odometer type: (<space> cycle, <CR> select, ^Z abort) Change odometer scale factor? : (Y/N) YES Enter odometer sf: dddd Change gyro scale factors? : (Y/N) YES Enter left gyro sf: d.ddddd Enter right gyro sf: d.ddddd Set new sensor values to Odometer type: <Digital odometer, Analog Odometer, unchanged> Odometer scale factor: < w/ dddd.000000 scale factor, unchanged> Gyro scale factors: LEFT d.dddddd RIGHT d.dddddd (Y/N) YES

6-25

Page 112

PLACER.BK : Placer 6 Page 26 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

6-26

Page 113

PLACER.BK : Placer 7 Page 1 Monday, February 24, 1997 9:30 AM

Chapter 7

Maintenance

7

The Placer GPS 450, 455 and 455DR sensors are designed to provide years of trouble-free operation. The units are simple to maintain. Should any major Trimble component fail (Placer, antenna, antenna cable, interface cables), a replacement can be ordered (or repaired/replaced, if under warranty) from Trimble Technical Assistance Center. The new component can be substituted for the failed component without concern for compatibility, since the Placer GPS 450, 455 and 455DR sensors do not rely on "matched" components. The major replaceable components for the Placer GPS 450 are listed in Table 4-1 and for Placer 455 and 455DR in Table 6-1. NOTE: The telephone number for the Trimble Technical Assistance Center and Repair center is 1-800-SOS-4-TAC. Contact them to order spare or replacement components. Special order processing may be required.

7-1

Page 114

PLACER.BK : Placer 7 Page 2 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Troubleshooting Should you experience problems with the Placer, be sure to check the simple items listed below prior to contacting Trimble Technical Assistance Center. Many "failures" are due to improper connections, or a misunderstanding of how the equipment should be installed or operated. ■

For operational problems, confirm the following:

■

All connections are made securely.

■

The Placer is connected to DC power source of 9 to 32 volts.

The ignition sense wire is connected either to the battery (+) for continuous power or to the ignition switch, so when ignition is turned on power is supplied to the Placer. If the Placer is receiving power and is properly connected, but communication cannot be established, check the following: ■

With the Terminal or PC configured to match the setup of the MDT port (default set to 9600, 8, 1, N), connect to the MDT port. To confirm communication, query the Placer for version number (>QVR<). The Placer should respond with the firmware version number and the release date.

>RVR PLACER 450; VERSION X.XX (MM/DD/YY) or >RVR PLACER 455; VERSION X.XX (MM/DD/YY) or If the problem persists, refer to the following sections titled Communications Troubleshooting and GPS Troubleshooting. If you have a Placer GPS 455DR unit and you are having problems with the heading sensor then consult the section on Dead Reckoning Troubleshooting. NOTE: Trimble offers the GPS Starter Kit (GPSSK) software package to assist users of the TAIP protocol. GPSSK runs on any IBM compatible PC and displays TAIP message data in an easy to read format. Please ask Trimble or your sales representative for more information on GPSSK.

7-2

Page 115

PLACER.BK : Placer 7 Page 3 Monday, February 24, 1997 9:30 AM

Maintenance

Communications Troubleshooting The standard Placer GPS 450 has two serial ports: ■

Radio Connector (port 0) and

■

MDT Connector (port 1).

Units with the DGPS option, Placer GPS 455s, have an additional port: ■

MDT/RTCM Connector which provides connection to the MDT (port 1) and also to an RTCM -104 port (port 2) for input of differential corrections.

If you are experiencing communications problems, refer to the table below. Symptom

Action

No output from Radio port (port 0)

If the Placer is not configured for a communication protocol (that is DIRECT connection) then there will be no output on the Radio port. If the Placer is configured for a communications protocol (CDPD or MAP 27) then, on power up, it will attempt to handshake with the external radio/modem and there will be some output (binary characters). If there is no output from the Radio port then:Check all connections are secure Check: Is the unit powered. Check ignition sense wire on the power cable is connected either to the battery (+) for continuos power or to the ignition (+) for switched power. Connect a null modem if output is to DTE equipment. Confirm baud rate, parity, data and stop bit settings are the same for port and radio/modem (9600, 8, 1, N). Use the MDT port to confirm settings for the Radio port (port 0): issue >QAP0< to get port 0 settings.

7-3

Page 116

PLACER.BK : Placer 7 Page 4 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Symptom No output from the MDT port (port 1)

Action Check: Is the unit powered. Connect the MDT side of the communications cable supplied (the other side is for the RTCM port, for Placer 455 only). Confirm baud rate, parity, data and stop bit settings are the same on the PC (9600, 8, 1, N).

Garbage output from the MDT port (port 1)

Check baud rate, parity, data and stop bit settings (9600, N,8,1) are the same on the PC.

MDT port does not respond to input messages.

Check: Is the unit powered. Connect the MDT side of the communications cable supplied (the other side is for the RTCM port). Check Appendix A , TAIP Protocol, for complete instructions. Confirm baud rate, parity, data and stop bit settings are the same for the MDT port and the PC (9600, 8, 1, N). Ensure that all queries, commands are delimited with > <. Ensure that all queries, commands are in CAPITAL letters. If sending a query command with a checksum, try without using the checksum. Confirm that message format is correct. Try a simple query, like >QVR<. This should cause a response regardless of GPS status.

No output from the RTCM port (port 2)

7-4

The RTCM port is for input only of RTCM formatted differential corrections. The MDT port (port 1) is the primary TAIP port.

Page 117

PLACER.BK : Placer 7 Page 5 Monday, February 24, 1997 9:30 AM

Maintenance

Symptom The differential corrections input on the RTCM port (port 2) are not being processed by the Placer.

Action Check: Is the unit powered. Connect the RTCM side of the communications cable supplied (the other side is for the MDT port, for Placer 455 only). Confirm baud rate, parity, data and stop bit settings are the same on the PC (9600, 8, 1, N). Use the MDT port to confirm settings for the RTCM port (port 2): issue >QAP2< to get port 2 settings.

GPS Troubleshooting To troubleshoot the GPS receiver portion of the Placer GPS 450/455 sensor, query the sensor with the TAIP command, >QST< on the MDT port, for the current status. See Appendix A for information on decoding the status message, and then refer to the table below. GPS Tracking Status Messages from TAIP >QST< Doing position fixes

Doing position fixes, GPS is providing the position solution.

Does not have GPS time yet.

No satellites visible, none have been visible since power on.

PDOP is too high

Three or more satellites are visible but the constellation geometry exceeds the PDOP mask level. Contact Trimble Technical Assistance Center.

No usable satellites

No usable satellites. Satellites may be visible but are too low in elevation or signal strength is too low. Be sure the antenna has a clear view of the sky.

Only 1, 2 or 3 usable satellites

Satellites are visible, and meet mask criteria, but not enough satellites are usable for a position fix. If only 3 usable satellites, but no position fix, then the receiver is set to the 3-D only mode and will require 4 satellites for a GPS position fix.

7-5

Page 118

PLACER.BK : Placer 7 Page 6 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

GPS Error Codes from TAIP >QST< Battery backup failed and/or Battery Powered timer/clock fault.

This message normally occurs when units are first installed but will disappear the first time power is switched off and then back on. If the message persists after cycling power contact Trimble Technical Assistance Center. The internal lithium battery has failed. This causes the satellite almanac, as well as the configuration settings to be lost when power is removed from the receiver. If the receiver is operating fine now, it should continue to do so as long as power is applied but all configuration information may be lost when power is removed. Contact Trimble Technical Assistance Center to arrange to have the battery replaced.

Antenna feedline fault

The antenna is not properly connected. Check connections and re-seat the antenna cable connections at both the antenna and receiver ends. Check that the antenna cable is not crimped. If no difference, try another antenna or antenna cable. If still no difference contact Trimble Technical Assistance Center.

The stored almanac is not complete and current

If the receiver has not tracked satellites for several days, the stored almanac may no longer be current. A current almanac will be read the next time a satellite is tracked. This will increase the time to first fix. During this time DR positions (for Placer 455DR units) will still be available. This could also be an indication of a failed internal battery. If so, there should also be a battery backup failure reported. Contact Trimble Technical Assistance Center to arrange for battery replacement.

7-6

Page 119

PLACER.BK : Placer 7 Page 7 Monday, February 24, 1997 9:30 AM

Maintenance

Dead Reckoning Troubleshooting Dead Reckoning Diagnostic Messages from Calibration using PLCRINIT.EXE No raw odometer pulses at any speed

There should be no odometer pulses when the vehicle is stationary. Confirm that the odometer signal meets the requirements specified in Chapter 6. If a signal conditioner or Hall Effect transducer was installed, verify that the installation was performed correctly. Test odometer sensor per manufacturers instructions, if provided. Verify that the connection is made to the correct signal source, if monitoring an existing speed/odometer signal.

No raw odometer pulses at low speeds, pulses are output at higher speeds.

Check that the Odometer Sensor has been installed correctly, as outlined in Chapter 6: Connecting the Vehicle Odometer. The odometer output may require a signal conditioner.

or Raw odometer pulses output while stationary.

Dead Reckoning Diagnostic Messages from TAIP >QX1< No pulses received from the odometer since startup.

If the vehicle has not been moved since the Placer GPS 455DR was powered on, this is not an error. If the vehicle has moved since power on, this is an error. Follow the instructions provided in Chapter 6 to verify the odometer installation. If the odometer pulses are not adequate, a signal conditioner or Hall Effect transducer will be required for installation.

7-7

Page 120

PLACER.BK : Placer 7 Page 8 Monday, February 24, 1997 9:30 AM

PLACER GPS INSTALLATION AND OPERATOR’S MANUAL

Dead Reckoning Diagnostic Messages from TAIP >QX1< Odometer scale factor out of tolerance.

The scale factor entered in Nominal Odometer Scale Factor is not within 50% of the actual scale factor. Follow calibration instructions in Chapter 6 to correctly calibrate the odometer.

Backup light is active.

Use this indicator to test your backup light connection.

Odometer Scale Factor.

The is the current calibrated odometer scale factor. This may differ for the Nominal Odometer Scale Factor entered during installation.

Gyro Hardware failed internal diagnostics.

Indicates gyro failure or board level failure inside the receiver. Check connections to the heading sensor and the Placer unit. If these are correct then contact Trimble Technical Assistance Center.

Gyro bias out of tolerance

The most likely cause for this message is connecting the heading sensor after powering up the unit. With all the sensors properly connected, cycle power off and then on, and re-check. If the error persists contact Trimble Technical Assistance Center.

Gyro scale factor out of tolerance.

7-8

This could be the result of a failed calibration. If no other errors are reported, retry the calibration procedure provided in Chapter 6.