Page 17

Installation

Installation

The Y-cable (splitter) shown in Figure 18 is an optional accessory that allows for connection of both a bar code wand and other external devices such as an external relay box (refer to Chapter 5). The single end of the cable is plugged into the terminal. The wand is connected to one of the split ends and another device to the other. Ø

NOTE: The Y-cable does not allow the use of two bar code devices from one terminal.

PROCEDURE – TERMINAL POWER UP Power up the terminal as follows: 1.

Plug the power pin into the terminal’s power port and power up the terminal. Refer to Figure 19 and 20. (a)

Route the power supply’s cord to the terminal as shown in Figure 19.

Figure 18: Y-Cable

Figure 19: Power Supply Cord Installation (b)

26

Plug the power pin into the terminal’s power port and power up the terminal. As soon as power is applied, the terminal’s LED will display the following information: 1)

Manufacturer’s name, model number and BIOS Version (Figure 20, Screen #1).

2)

Idle Screen (Date and Time) (Figure 20, Screen #2).

27

Page 18

Installation

Installation PROCEDURE – ACCESS PANEL INSTALLATION After the terminal has been successfully powered up, the access panel can be reinstalled.

TIMEAMERICA 6.03 1-1-3-1-0-1-0

1.

Install the access panel on the terminal. Refer to Figure 21. (a)

Slide the access panel upward on the terminal.

(b)

Install the hex head screw on the terminal. Use the nut driver provided.

Screen # 1

A

8:14

:32

FRI 14

FEB 2003

Screen # 2

Figure 20: Power On Screens

Figure 21: Access Panel Installation

28

29

Page 19

Operator Interface

Chapter 3

Idle Screen

Operator Interface

The terminal’s Idle Screen (also shown in Figure 22) is displayed when the terminal is in the idle state. The Idle Screen shows the current date (including the day of the week) and time on the upper line and your company’s name (or other programmed message) on the bottom line. When entering data into the terminal, a person can always return to the Idle Screen by pressing the [CLEAR] key.

Purpose: The purpose of this chapter is to familiarize you with the basic operation of the TA620 Data Collection Terminal. The following is provided: •

A functional overview of the terminal’s display and keypad.

•

An explanation on how to use a magnetic stripe and bar code badge.

•

An explanation on how to use a bar code wand.

Advanced Features The TA620 in corporates many advanced features. Several of them come standard, while others are available as options. Standard features include: Supervisor Editing, Data Input Validation, Profile Lockout Scheduling, Employee Messaging, and Programmable Function Keys.

Keypad Layout The TA620 has 20 keys for entering alphanumeric data. Its advanced design differs from conventional terminals, as there are no buttons to press. Each key contains a very sensitive membrane type switch that activates upon touch. Its design also creates a watertight seal and allows for entry of both upper and lower case alphanumeric characters, as well as various special characters mentioned earlier.

It is important to note that the terminal’s advanced features are software controlled or programmed and are not explained in this manual. In addition, they may require optional software modules in order to activate their functionality. Consult your local Time America sales representative for additional information.

Programming Software The TA620 is designed for use in conjunction with Time America software packages (sold separately). These software packages control the terminal’s programming and the functionality of its standard and optional features.

Display The TA620 has a two-line dot matrix LCD display as shown in Figure 22. Each line can display up to 20 upper and lower case alphanumeric characters, including special characters such as a period (.), dash (-), colon (:), equals sign (=), and a forward slash(/).

Figure 23: Terminal Keypad Each key on the keypad has one or more dedicated functions. Each of the ten numeric function keys (0-9) along with the [IN] and [OUT] keys can be user programmed to serve a special purpose (refer to the TA620 Technical Reference Manual). The TA620’s keypad also contains special keys to facilitate entering data into the terminal and includes [ENTER], [CLEAR], [ALPHA SHIFT], [BACKSPACE], and [FORWARD].

Key Functions The function of each key on the terminal’s keypad is as follows:

A

8:14

:32

FRI 14

FEB 2003

KEY

FUNCTION

Backspace

Normally used to move the display cursor back 1 character. In alpha mode, it is used to scroll back through the Alphabet Selection Menu. In configuration mode, it is used to scroll back through steps.

Forward

Normally used to move the display cursor forward 1 charact er. In alpha mode, it is used to

Figure 22: Terminal Display with Idle Screen

30

31

Page 20

Operator Interface

Operator Interface scroll forward through the Alphabet Selection Menu. In configuration mode, it is used to scroll forward through steps.

Entering Alpha Characters To enter upper case alpha characters, press the [ALPHA SHIFT] key once to display the Upper Case Alphabet Selection Menu on the bottom (2nd) line of the terminal’s display as shown in Figure 24.

Left Up arrow

Unassigned

Center Up arrow

In alpha mode, it is used to select an alpha character.

Right Up arrow

Unassigned

1

Displays the numeric character 1.

2

Displays the numeric character 2.

3

Displays the numeric character 3.

ABCDEFGHI >J<KLMNOPQ

4

Displays the numeric character 4. Factory programmed to punch an employee Out For Lunch after entering the employee’s ID number via the keypad or badge swipe.

Figure 24: Upper Case Alphabet Selection Menu

5

Displays the numeric character 5. Preprogrammed in the software to enter tips for an employee after entering the employee’s ID number via the keypad or badge swipe.

6

Displays the numeric character 6. Factory programmed to punch an employee In From Lunch after entering the employee’s ID number via the keypad or badge swipe.

7

Displays the numeric character 7. Preprogrammed in the software to punch an employee Out For Break after entering the employee’s ID number via the keypad or badge swipe.

8

Displays the numeric character 8.

9

Displays the numeric character 9.

0

Displays the numeric character 0. Preprogrammed in the software to transfer departments after entering the employee’s ID number via the keypad or badge swipe.

Enter Category: Job

The encapsulated letter on the bottom line (J in the above example) represents the letter to be selected. Scroll through each letter by pressing the [FORWARD] or [BACKSPACE] key, then select the letter and transfer it to the top line (as shown above) by pressing the Center Up arrow or the [ENTER] key. To enter lower case alpha characters, press the [ALPHA SHIFT] key twice (or a second time while entering upper case characters). Pressing the [ALPHA SHIFT] key a third time exists the terminal’s alpha mode. If entering lower case letters and you wish to enter upper case characters again, you must exit and re-enter the terminal’s alpha mode. EXAMPLE

To enter the word Job, perform the following steps: 1.

Press the [ALPHA SHIFT] key once.

2.

Encapsulate the upper case letter J from the Upper Case Alphabet Selection Menu by pressing the [FORWARD] or [BACKSPACE] key.

3.

Press the Center Up arrow or the [ENTER] key.

4.

Press the [ALPHA SHIFT] key again.

5.

Encapsulate the lower case letter o from the Lower Case Alphabet Selection Menu by pressing the [FORWARD] or [BACKSPACE] key.

CLEAR

Returns the terminal to the idle state without saving any of the operations being performed.

ALPHA SHIFT

Enables the terminal’s alpha mode (see Entering Alpha Characters on next page)

ENTER

Enters data into the terminal

6.

Press the Center Up arrow or the [ENTER] key.

IN/OUT

Factory programmed to punch an employee in or out after entering the employee’s badge or ID number via the keypad or badge swipe.

7.

Repeat steps #5 and #6 for the lower case letter b.

8.

Press the [ALPHA SHIFT] key a third time (to exit).

32

33

Page 21

Operator Interface

Operator Interface

Basic Operation

Magnetic Card Reader

Although the TA620’s function keys can be programmed to operate in a variety of ways, the following procedures will explain how to punch IN and OUT for the shift and IN and OUT for lunch with the factory default programming.

The TA620 contains an internal magnetic card reader. The reader is a Track 2 ABA head for reading credit card style magnetic cards through the terminal’s slot. When swiping a magnetic card or badge through the terminal:

PROCEDURE – PUNCHING IN OR OUT FOR THE SHIFT 1.

2.

•

The magnetic stripe should be facing the right side of the terminal’s slot as shown in Figures 25 and 26.

•

Swipe the card or badge briskly through the terminal’s slot; otherwise a message that reads PLEASE TRY AGAIN will appear on the t erminal’s display. If this message appears, check the location of the magnetic stripe on the badge, and try again. If this error continues, refer to the Diagnostic section of this manual for instructions on how to test magnetic stripe badges.

Enter the employee’s ID number via the keypad entry or badge swipe. (a)

If entering the employee’s ID number via keypad entry, first enter the ID number, then press the [ENTER] key. The prompt ENTER FUNCTION will appear on the terminal’s display.

(b)

If entering the employee’s ID number via badge swipe, the prompt ENTER FUNCTION will appear on the terminal’s display.

Press the [IN] key to record punch IN t ransaction or the [OUT] key to record punch OUT transaction.

NOTE: Refer also to Appendix E for standards and specifications on magnetic stripe badges.

PROCEDURE – PUNCHING IN OR OUT FOR LUNCH 1.

Enter the employee’s ID number via the keypad entry or badge swipe.

2.

Press the [4] key to record a punch OUT to lunch transaction or the [6] key to record a punch IN from lunch transaction.

Figure 25: Magnetic Badge

Figure 26: Magnetic Badge Usage

34

35

Page 22

Operator Interface

Operator Interface

Internal Bar Code Reader

External Bar Code Wand

Optionally, the TA620 can have an internal bar code reader. This type of reader is used to read visible and infrared 3 of 9 bar coded cards through the terminal’s slot. When swiping a bar coded card or badge through the terminal:

When using a bar code wand, swipe the wand briskly across the bar code on the card as shown in Figure 29; otherwise a message that reads PLEASE TRY AGAIN will appear on the terminal’s display. If this message appears, check the bar code wand and the bar code on the card, and try again. If this error continues, refer to the Diagnostics section of this manual for instructions on how to test a bar coded badge with a bar code wand.

•

The bar codes should be facing the left side of the terminal’s slot as shown in Figures 27 and 28.

•

Swipe the card briskly through the terminal’s slot; otherwise a message that reads PLEASE TRY AGAIN will appear on the terminal’s display. If this message appears, check the location of the bar codes on the badge, and try again. If this error continues, refer to the Diagnostic section of this manual for instructions on how to test bar code badges.

NOTE: Refer to the Bar Code Wand Connection procedure in Chapter 2 for additional information pertaining to the bar code wand. Refer also to Appendix F for standards and specifications on bar codes.

NOTE: Refer to Appendix F for standards and specifications on bar codes.

Figure 27: Bar Code Badge

Figure 29: External Bar Code Wand Usage

Special Function Label Application

Figure 28: Bar Code Usage

36

One of the most important features of the TA620 is that in addition to the IN and OUT keys, each function key (0-9) can be specially programmed to collect up to six items of data, plus the initial employee ID and time stamp. To address this feature, two function overlay labels (shipped with the terminal) are used to cover the terminal’s FUNCTIONS identification box (located on the left side on the keypad) and identify special and/or user-programmed functions.

37

Page 23

Operator Interface

Operator Interface

The gray label is imprinted only with lines to allow programmed functions to be typed or written on it. When peeled off and applied, it completely covers the keypad’s FUNCTIONS identification box. The first (narrow) column of the gray label should identify the key used to activate the programmed function. The second (wide) column should identify or describe the function. NOTE: To prevent the typed or written information from smearing, cut off the un-imprinted (blank) portion of the long clear label and apply it directly over the gray label (refer to Figure 30).

Figure 31: Clear Cutout Application

Figure 30: Gray Label Application In addition to the gray label, a long clear imprinted label is also provided. This label contains cutouts that identify the names of various functions that can be programmed into the terminal, plus a series of ENTER cutouts to indicate that the [ENTER] key should be pressed to activate the function. The cutouts must be hand cut from the label using scissors or a precision cutting knife. They are applied on top of the gray label. Each row on the gray label can accommodate two clear cutouts. The number cutouts are placed in the first (narrow) column of the gray label and identify the name of the function key. The function cutouts are placed in the second (wide) column of the gray label and identify the name of the function (refer to Figure 31).

38

39

Page 24

Field Upgrades and Servicing

Chapter 4

•

Configuration

• The TA620 Data Collection Terminal contains a built -in configuration program. The configuration mode is used to setup the terminal for proper operation.

Select or enter the printer •

1 = serial

•

2 = Parallel

Select or enter the Transaction Time Out (in minutes) •

0 – off

•

30 = 30 minutes

Configure RS485: (RS485 terminals only)

Terminal Configuration: After installation, configure the terminal as explained next. The use of the Configuration badge (supplied with the terminal) is necessary to activate the terminal’s configuration mode. The badge is labeled with nine zeros (000000000). PROCEDURE – TERMINAL CONFIGURATION 1. Configuring Date and Time: • Swipe the Configuration Badge (00000000)

•

Swipe the Configuration Badge (00000000)

•

Select option 2 for Ports <Press ENTER>

•

Select option 1 <Press ENTER>

•

Select or enter the baud rate •

0 = 1200

•

Select option 1 for DATE <Press ENTER>

•

1 = 2400

•

Select or enter the Day, Month, Year (DDMMYYYY) <Press ENTER>

•

2 = 4800

•

Select or enter the Time (HH:MM) <Press ENTER> (enter time in military format, 2:00 PM = 14:00)

•

3 = 9600

•

4 = 19,200

•

2. Configuring Ports:

<Press ENTER>

Configure Modem: (For Modem terminals only) Note: This unit, unlike previous models, must be re-configured to use another port. Configure RS232: •

Swipe the Configuration Badge (00000000)

•

Select option 2 for Ports <Press ENTER>

•

Select option 0 for RS232 <Press ENTER>

•

Select or enter the baud rate •

0 = 1200

•

1 = 2400

•

2 = 4800

•

3 = 9600

•

4 = 19,200

•

Swipe the Configuration Badge (00000000)

•

Select option 2 for Ports <Press ENTER>

•

Select option 0 <Press ENTER>

•

Select or enter the baud rate •

0 = 1200

•

1 = 2400

<Press ENTER> •

Select or enter the Answer Window (HHMMHHMM) for the starting and the ending times <Press ENTER> (use military time format, Example: clock will not answer during business hours and only answer between the hours of 8:00 PM and 6:00 AM, the select (20000600.)

<Press ENTER>

40

41