The text of a manual · part 2 of 4

TA620 Data Collection Terminal Installation and Operation Guide, pages 9 to 16

Pages 9 to 16 of 32

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Time America TA620 and Synel TA620

Page 9

Installation

Installation

INSTALLATION PROCEDURE – SERIAL COMMUNICATIONS

INSTALLATION PROCEDURE – LAN COMMUNICATIONS

This procedure is designed for serial communications and is used for single terminal installations. It connects the TA620 Data Collection Terminal directly to the host computer (PC) with an RS232 serial cable. Each RS232 serial port on the PC can support one serial connection to a terminal up to 100 feet away.

This procedure is designed for LAN communications and is used for single terminal installations over 100 feet away and for multiple terminal installations. It connects the TA620 Data Collection Terminal(s) directly to the host computer (PC) with an RS485 LAN cable. Ø

NOTE: Do not confuse terminal’s LAN communication system with the LAN (Ethernet connection) installed on your PC. They are different and do not operate in conjunction with each other.

The terminal’s RS485 LAN serial port is located on the lower left side of the chassis. It is a 6position, 4-pin port that accepts a male RJ11 modular connector and is identified by the marking RS485. Each RS232 port on the PC can support up to 32 LAN terminals with up to 4,000 feet of cable. The RS232 port on the PC must be used in conjunction with an RS232/RS485 converter to complete the connection. Ø

NOTE: An internal RS485 driver card installed in the PC can support up to 32 LAN terminals with up to 5,000 feet of cable.

Ø

When wiring a network, always follow the electrical wiring codes in your area. The LAN cable (RS485 Wire) shown in Figure 2 is a shielded CAT5 cable.

Typical components used in a LAN installation are: •

RJ11 Distribution Boxes (one for each terminal plus one for the P C connection)

•

Standard RJ11 Modular Cables (one cable is supplied with each terminal, you will need one additional cable for the connection from the PC to the first distribution box)

•

RS485 Wire (two conductor CAT5 shielded)

•

Communications Converter (RS232 to RS485)

Figure 1: Serial Communication Installation Note: When installing a single terminal using RS232 communications, either of two wiring configurations may be used; a standard RJ11 cable up to 50’ in length may be run from the terminal directly to the host PC, or in some cases six -conductor shielded cable may be run between two RJ11 distribution boxes. In the later case, two standard RJ11 cables would then connect both the host PC and the terminal to the RJ11 distribution boxes. In either case, an adapter is required to connect the standard RJ11 cable to the host PC. Use either CBL1180 for PCs with a 25 pin serial port, or CBL1195 for PCs with a 9 pin serial port.

10

11

Page 10

Installation

Installation

1. Install the terminal per the diagram shown in Figure 2. Ø NOTE: Part numbers to all components used are shown below.

INSTALLATION PROCEDURE – INTERNAL MODEM COMMUNICATIONS This procedure is designed for internal modem communications and is used for single or multiple terminal installations at remote locations. It enables TA620 terminals equipped with internal modems (optional feature) to communicate with a host computer (PC) with an internal or external modem attached to it. The terminals connect directly to a regular telephone line and may be located at remote locations or at the main polling site using standard telephone lines and direct access extensions. Ø

NOTE: To prevent damage to the terminal, do not use a telephone system with digital lines. If necessary, purchase a digital-to-analog converter in cases where analog lines are not available. Most digital phone systems allow the administrator to change the state of certain lines to analog.

1.Install the terminal per the diagram shown in Figure 3.

Figure 3: Internal Modem Communication Figure 2: LAN Communication

Terminals equipped with a modem port, will not have an RS485 port. The modem port is located in the lower left corner of the terminal. The port is a 6-position, 4-pin female port that accepts a male RJ11 modular connector. Although the port is identified RS485 (chassis marking), a self-adhesive label that reads MODEM is applied over the existing chassis marking as shown in Figure 4.

12

13

Page 11

Installation

Installation INSTALLATION PROCEDURE – EXTERNAL MODEM COMMUNICATIONS This procedure is designed for external modem communications and is used when an external modem is connected to the terminal’s RS232 port. External modem communication enables the user to:

Ø

•

Communicate at higher speeds (up to 9600 baud).

•

Use a LAN terminal for modem communications.

NOTE: When using this method of communication, refer to the terminal configuration procedure in Chapter 4 and ensure that External Modem Parameter is enabled (step #3).

Terminals connect to an external modem using a serial connection. The modem then uses a standard telephone line connected to a telephone jack. 1.Install the terminal per the diagram shown in Figure 6.

Figure 4: Modem Label Application The internal modem is compatible with Bell 103/212A and CCITT V.21/V.22 devices. It supports both asynchronous and synchronous (SDLC) communication and can communicate over telephone lin es at 300, 1200, and 2400 baud. When using the installation procedure for internal modem communications, ensure that the following tasks are accomplished: •

Route and connect one end of the telephone cable to the terminal (refer to Figure 4)

•

Route and connect the other end of the telephone cable into your RJ11 modular telephone wall jack (refer to Figure 5).

Figure 6: External Modem Communication

Figure 5: Telephone Wall Jack Connection Ø

NOTE: If an RJ11 modular wall jack is not available, obtain an adapter from your lo cal telephone company.

14

15

Page 12

Installation

Installation

INSTALLATION PROCEDURE – REMOTE LAN COMMUNICATIONS This procedure is designed for remote LAN communications and is used for multiple terminal installations with remote locations using only one telephone line to communicate to each group of remote terminals. A host computer (PC) with an internal or external modem installed can communicate with multiple remote terminals located at the same site using a remote LAN configuration.

1.

Install the terminal per the diagram shown in Fi gure 7. Ø

NOTE: Part numbers to all components used are shown.

A remote modem can support up to 128 terminals using up to 5,000 feet of cable using the Time America RS232 to Remote RS485 Smart Communications Converter. The Smart Converter attaches to the external modem and converts the modem’s RS232 communications protocol to RS485. Typical components used in a remote LAN configuration are: •

LAN distribution boxes

•

Standard (RJ11) modular cable

•

RS485 wire

•

Smart Communications Converter (RS232 to Remote RS485 LAN)

•

Communications converter cable

•

External modem

Figure 7: Remote LAN Communication

16

17

Page 13

Installation 2.

Installation

Configure the Smart Communications Converter.

INSTALLATION PROCEDURE – INTERNAL ETHERNET COMMUNICATIONS

Perform this step to ensure that the Smart Communications Converter (Figure 7) communicates at the same speed at the external modem. The converter and device attached to the converter’s RS232 port (8-pin DIN) must be set to communicate at the same speed. The RS232 baud rate on the converter defaults to 1200 baud. Ø

This procedure is designed for Ethernet communications and is used for single or multiple terminals installations. It connects the TA620 Data Collection Terminal to the host computer (PC) with a standard Cat 5 UTP cable through your companies LAN or WAN. An Ethernet solution can support unlimited terminals through Ethernet using TCP/IP addressing.

NOTE: The RS485 baud rate is hard coded to 9600 baud.

Initially, the converter will display RS232 --- RS485. This is the converter’s Idle Screen. The following instructions explain how to change the RS232 baud rate on the converter.

Typical components used in an Ethernet configuration are: •

LAN distribution boxes (RJ45) Standard (Cat 5 UTP) modular cable

(a)

Simultaneously press the [*] and the [1] key on the converter’s keypad.

•

(b)

The converter will display ENTER COMMAND.

When using the installation procedure for internal modem communications, ensure that the following tasks are accomplished:

•

Press the [1] key to display the current RS232 baud rate. If pressed, the converter will display RS232 BAUD IDX X where X is the baud rate index between 0 and 6. See chart below to convert the index number to the actual baud rate.

•

Press the [2] key to change the RS232 baud rate. If pressed, the converter will display ENTER RS232 IDX X. Enter the index value corresponding to the new baud rate that matches the communication speed of your external modem per the chart shown below.

Index

Baud Rate

Index

Baud Rate

0

300

4

4800

1

600

5

9600

2

1200

6

19200

3

2400

•

Route and connect one end of the Cat 5 UTP cable to the RJ45 connector on the terminal.

•

Route and connect the other end of the Cat 5 UTP cable (not to exceed 100 meters) to your RJ45 modular jack to a Network Hub or Switch. Ensure that it is capable of 10baseT communication; some hardware can only communicate at 100Base speeds.

For example, if using a 2400 baud modem, set the index on the converter to 3. Ø •

NOTE: The baud rate for LAN communications is 9600. Do not change the baud rate on the terminal.

The converter will then display RS232 BAUD IDX where X is the newly entered baud rate index.

Figure 8: Ethernet Cable Communication

18

19

Page 14

Installation

Installation

MOUNTING PROCEDURE – TA620 TERMINAL down from the ceiling and place the marks for the top set of mounting screws at equal distances from the ceiling.

The following procedure explains how to mount the TA620 Data Collection Terminal.

Ø

1.

Removing the access panel and mounting bracket from the terminal. Refer to Figure 9. (a)

Remove the hex screw from the terminal. Use the nut driver.

(b)

Slide the access panel downward to remove it from the terminal.

(c)

Slide the mounting bracket downward to remove it from the terminal. Ø

(b)

2.

NOTE: Ensure that the bracket’s large mounting posts are on the bottom.

(c)

Remove the bracket from the wall and drill the appropriate size pilot holes in the areas marked. If the screw anchors are used, ensure that the anchors fit snugly in the holes with their tops flush with the drywall or concrete.

(d)

Reposition the mounting bracket on the wall and install four mounting screws.

Figure 9: Access Panel & Mounting Bracket Removal 1a. If mounting a terminal on a desktop:

Mark the location of the bracket’s four screw mounting holes on the wall. Use a pencil, pen or scribe (whichever is available and/or appropriate). Ø

NOTE: The mounting bracket can be installed in two directions. For wall mounting, the large posts should be positioned at the bottom of the terminal. For desktop mounting, refer to step #1a below.

NOTE: Ensure that the bracket is positioned in a location that facilitates connection of the terminal to the RS485 (LAN) or modem communication cables.

Figure 10: Mounting Bracket Installation 3.

Attach the terminal to the mounting bracket. Refer to Figure 11.

(a)

Remove the mounting bracket as explained in Figure 9.

(a)

Position the terminal on the mounting bracket.

(b)

Rotate and reinstall the bracket with the large posts facing towards the top of the terminal. Do not install the access panel until all cables have been connected to the terminal’s ports per the applicable procedure.

(b)

Slide the terminal downward on the mounting bracket until locked in place.

Install the mounting bracket on the wall. Refer to Figure 10. (a)

Position the mounting bracket on the wall and hold. Use a small level to ensure that the bracket is straight. In some cases this will cause the terminal to appear crooked because the ceiling of the facility may not be level. An alternate method to ensure that the terminal appears straight upon completion of installation is to measure

20

21

Page 15

Installation

Installation PROCEDURE – SERIAL PRINTER CONNECTION Ø

NOTE: Perform this procedure only if connecting a serial printer to the TA620 Data Collection Terminal. Refer to the terminal configuration procedure in Chapter 4 and ensure that the Default Printer Parameter is set to SERIAL (step #9)

The serial printer is connected to the terminal through its RS232 serial communications port. The port is located adjacent to the RS485 port . It is a 6-position, 4-pin female port that accepts a male RJ11 modular connector and is identified by the marking RS232. If the terminal is configured for serial communication, the terminal cannot print through the serial port unless an A/B switch box is used. 1.

Connect a serial printer to the terminal per the diagram shown in Figure 13.

Figure 11: Terminal and Mounting Bracket Attachment PROCEDURE - POWER SUPPLY ATTACHMENT 1.

Plug the terminal’s power supply into the wall outlet. Refer to Figure 12. Do not plug the module’s power pin into the terminal’s power plug at this time. Ø

NOTE: The power supply provided with the terminal is for 110VAC outlets. If attaching to a 220VAC outlet, the optional 220VAC to 9VDC power supply is necessary. Refer to the “Power Supplies” section in Chapter 5.

Figure 13: Serial Printer Connection

Figure 12: Power Supply Attachment

22

23

Page 16

Installation

Installation

PROCEDURE – PARALLEL PRINTER CONNECTION Ø

NOTE: Perform this procedure only if connecting a parallel printer to the TA620 Data Collection Terminal. If connecting a parallel printer to the terminal, refer to the terminal configuration procedure in Chapter 4 of this manual and ensure that the Default Printer parameter is set to PARALLEL (step #9).

The terminal’s parallel printer port is used to connect a standard parallel printer. The port is located on the right side of the terminal and is a 25-pin female connector. 1.

Connect a parallel printer to the terminal (#3) per the diagram shown in Figure 14. (a) (b)

Connect the male pin side of the parallel printer cable to the terminal’s parallel printer port. Connect the Centronics end of the parallel printer cable to the printer.

PROCEDURE – BAR CODE WAND CONNECTION The optional bar code wand, when connected, uses only 3 of the 6 pins available on the terminal’s wand port (DIN connection). The wand port is located in the left corner of the terminal and is identified by the marking WAND. If bar codes are available, a bar code wand simplifies data input. If a bar code gun (non-contract reader) is used, the center pin of the DIN connection supplies the additional power. The terminal uses 2 of the remaining pins as lo gic lines for external controls. 1.

Connect a bar code wand (#9) to the terminal (#3) per the diagram shown in Figure 16. (a)

Connect the wand’s plug to the terminal’s wand port.

Figure 14: Parallel Printer Connection The parallel printer cable shown in Figure 15 is available locally through most computer dealers. One end of the cable is a male DB-25 connector; the other end is a 36-pin Centronics type connector to match the parallel port on the printer.

Figure 15: Parallel Printer Cable

24

Figure 16: Bar Code Wand Connection (b)

If using other external devices (such as the signal control relay) in conjunction with the bar code wand (see Figure 17), connect the male end of the Y-cable shown in Figure 18 to the terminal’s wand port, then connect the wand to one of the female ends of the Y-cable.

Figure 17: Bar Code Wand

25