The text of a manual · part 1 of 4
TA620 Data Collection Terminal Installation and Operation Guide, pages 1 to 8
Pages 1 to 8 of 32
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Time America TA620 and Synel TA620
Page 1
TA620
™
DATA COLLECTION TERMINAL
Copyright and Trademark: © 2003 TIME AMERICA, INC. All rights reserved. This document contains information proprietary to Time America, Inc. No part of this document may be copied, distributed, or transmitted in any form or by any means, electronic, mechanical, or otherwise, including photocopying, recording, or storage in any information retrieval system without the express written permission of Time America, Inc. Copying includes translating into another language or format. Printed and bound in the United States of America.
Ø TERMINAL INSTALLATION Ø OPERATOR INTERFACE Ø CONFIGURATION Ø INTERNAL MODEM OPTION Ø INTERNAL ETHERNET OPTION Ø INTERNAL BAR CODE READER OPTION Ø MEMORY EXPANSION OPTION Ø ENHANCED DISPLAY OPTION
TIME AMERICA and TA620 are registered trademarks of Time America, Inc. Any other brand and product names used in this manual are trademarks or registered trademarks of their respective holders. FCC Warning: Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. The equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instruction manual provided, it may caus e interference with the radio and television reception in a residential area, in which case the user will be required to correct the interference at his or her own expense. If this equipment causes interference, try to correct the problem by: F F F
Reorienting the receiving antenna. Relocating the terminal with respect to the receiver with which it interferes. Plugging the terminal into a different AC outlet, and putting the terminal and receiver on different branch circuits.
FCC Compliance (on hardware equipped with modem): This equipment complies with Part 68 of the FCC rules. Upon request, furnish the following information furnish the following information to the telephone company.
INSTALLATION AND OPERATION GUIDE © 2003 Time America, Inc 51 West Third Street Tempe, Arizona 85281 All Rights Reserved
F F F F F
Manufacturer: Time America, Inc. Model: TA620 Data Collection Terminal FCC registration number: 4G3USA-21602-DT-E Ringer equivalence: 0.7B USOC modular telephone jack: RJ11
Lithium Battery Caution: The circuit board on this terminal contains a lithium battery to protect data or programs stored in the Random Access Memory (RAM). Do not, under any circumstances, attempt to replace the lithium battery in the terminal. Failure to comply may invalidate your warranty. Only qualified personnel wearing proper eye protection should perform battery replacement. CAUTION: Danger or explosion could occur if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Discard used batteries per manufacturer’s instructions.
Page 2
Preface
Read This First About This Manual This manual is the factory documentation sent with each new TA620 Data Collection Terminal that explains how to install, operate, configure, and upgrade the unit. Publication Date and Revision The publication date of this manual is April 1, 2003, and is designated as Revision C. Changes and Updates The contents of this manual are subject to change without notice. Any user of this manual should verify from Time America, Inc. that the information is current and accurate. Time America, Inc. assumes no responsibility for the use of information and procedures that have changed or are no longer in effect. Procurement Copies of this manual can be obtained through your local sales representative. Customer Comments Every effort was made to ensure that the information contained in this manual was accurate at the time of publication. Report any observed errors or omissions to, Time America, Inc. Attn: Technical Publications, 51 West Third Street, Suite 310, Tempe, AZ 85281.
Page 3
Contents Chapter 1 ...................................................................................................................1 Product Overview and Features ...............................................................1 Configurations.............................................................................................3 General Specifications...............................................................................4 Chapter 2 ...................................................................................................................6 Installation ............................................................................................................6 Location/Site Requirements......................................................................6 Precautions...................................................................................................6 Maintenance................................................................................................6 Unpacking and Inspection.........................................................................7 Installation Tools ........................................................................................7 Communication Methods..........................................................................8 Installation Overview.................................................................................9 INSTALLATION PROCEDURE – SERIAL COMMUNICATIONS....................10 INSTALLATION PROCEDURE – LAN COMMUNICATIONS.........................11 INSTALLATION PROCEDURE – INTERNAL MODEM COMMUNICATIONS13 INSTALLATION PROCEDURE – EXTERNAL MODEM COMMUNICATIONS
.....................................................................................................................15 INSTALLATION PROCEDURE – REMOTE LAN COMMUNICATIONS.........16 INSTALLATION PROCEDURE – INTERNAL ETHERNET COMMUNICATIONS ....................................................................................19 MOUNTING PROCEDURE – TA620 TERMINAL...........................................20 PROCEDURE - POWER SUPPLY ATTACHMENT .........................................22 PROCEDURE – SERIAL PRINTER CONNECTION ........................................23 PROCEDURE – PARALLEL PRINTER CONNECTION...................................24 PROCEDURE – BAR CODE WAND CONNECTION.......................................25 PROCEDURE – TERMINAL POWER UP .......................................................27 PROCEDURE – ACCESS PANEL INSTALLATION........................................29
Chapter 3 .................................................................................................................30 Operator Interface..............................................................................................30 Advanced Features...................................................................................30 Programming Software ............................................................................30 Display........................................................................................................30 Idle Screen .................................................................................................31 Keypad Layout..........................................................................................31 Key Functions...........................................................................................31 Entering Alpha Characters ......................................................................33 Basic Operation.........................................................................................34
Magnetic Card Reader.............................................................................35 Internal Bar Code Reader........................................................................36 External Bar Code Wand.........................................................................37 Special Function Label Application......................................................37 Chapter 4 .................................................................................................................40 Configuration .....................................................................................................40 Chapter 5 .................................................................................................................43 Field Upgrades And Servicing ........................................................................43 Internal Bar Code Reader........................................................................43 Signal Control Relay ................................................................................47 Display Contrast Adjustment .................................................................50 Appendix A .............................................................................................................53 Magnetic Stripe Reader and Card ...................................................................53 Appendix B.............................................................................................................54 Bar Codes............................................................................................................54 Appendix C.............................................................................................................56 Technical Support..............................................................................................56
Page 4
Chapter 1
Introduction Congratulations! The TA620 Data Collection Terminal you’ve purchased represents a true technological advancement in the time & attendance and data collection field. Its advanced design offers exceptional reliability and flexibility and contains many features not found on conventional data collection terminals. This manual contains the necessary technical and reference informat ion needed to properly install, configure, operate, and upgrade your terminal.
Product Overview and Features The TA620 is a full-featured data collection terminal that allows several forms of data input and communication methods. It provides an easy and cost effective means of recording employee time & attendance and automating the collection of Job Costing/Cost Accounting data. Some of the major features of the terminal are: 1.
Five forms of data input. This includes: Keypad, Magnetic Stripe, Bar Code (visible and infrared), Bar Code Wand, and External Access Readers.
2.
Four forms of communication. This includes: RS485 Local Area Network (LAN), Internal and External Modem, Ethernet, and Direct RS232. Depending on the communication method used, the terminal can communicate at baud rates from 300 bps to 10 mbps.
3.
Parallel printer support. A unique feature of the TA620 is an integrated 25-pin parallel port, which supports most standard parallel printers.
4.
Durable construction. The TA620 is constructed of a special impact resistant plastic material that is lightweight and attractive. The terminal’s mounting bracket is designed for both wall hanging and desktop installations.
5.
Feather touch membrane keypad. This type of keypad creates a water tight seal and allows for entry of both upper and lower case alphanumeric characters as well as special characters such as a dash (-), period (.), and spaces. It represents the latest technology available to provide you with years of trouble free operation.
6.
40 character (2 lines x 20 characters) backlit LCD display. This type of display allows twice the amount of information to be viewed at once compared to some terminals.
1
Page 5
Introduction 7.
Internal lithium battery. The internal lithium battery provides constant power to the terminal’s memory to keep your data safe in the event of a complete power outage. The internal battery not only saves the memory, but also keeps the time and calendar accurate. Once power resumes, the battery automatically charges. Ø
8.
Introduction
NOTE: With the addition of an optional external battery backup, all terminal functions remain 100% operational if power is removed.
Accept/Reject tones. The TA620 has two distinct accept/reject tones. When an employee does not follow proper terminal operation, he/she not only receives an error message, but also receives a series of low, short reject tones. A correct entry is followed by a high, short accept tone. For noisy environments, an optional feedback enhancer can be added to provide a green “accept” light, red “reject” light, and amplified accept/reject tones. F
9.
NOTE: The feedback enhancer cannot be used with the Signal/Access control feature (described on the next page) since both utilize the same signal port.
Ten programmable function keys: In addition to the [IN] and [OUT] keys, each function key (0-9) on the keypad can be programmed to collect up to four items of data, such as Job numbers, Tip amounts or Quantities for Piece Wage. The data input source for each function key can be restricted to the keypad, magnetic stripe or bar code.
10. Background polling: This feature allows employees to punch at the terminal while communication is taking place with the host computer.
You can also control punching by time of day, day of week, and even give specific messages to employees as to why they were locked out. Ø
NOTE: Supervisors may be allowed to override a lockout. When used with access control, you can also define schedules for employee access.
15. Data input validation. This feature eliminates keystroke errors and increases job-costing accuracy by allowing you to download tables of valid entries. When an employee keys or swipes a number in response to your prompt, the entered num ber is compared to the table of valid numbers downloaded. The terminal will reject bad entries and accept valid ones, while optionally displaying the particular item’s name. This feature may also be used to restrict employees from entering unauthorized departments. 16. Employee messaging. After an employee enters his/her badge or ID number (via keypad or badge swipe), the terminal can display a 16-character message to that employee. Messages such as employee’s name, hours worked, or work location can be downloaded to the terminal. 17. Enhanced memory. While most data collection terminals come standard with 32K or 64K of Random Access Memory (RAM), the TA620 comes standard with 128K. This allows two to four times the amount of information to be stored in the terminal at no extra cost. Memory can also be upgraded to 256K.
Configurations The TA620 Data Collection Terminal is offered in various configurations.
11. Supervisor editing. Using a special supervisor badge, the terminal enters supervisor mode, which will allow supervisors to add missing punches, delete erroneous punches and even record “leave exceptions” such as sick days. This is very useful in situations where supervisors do not have access to a computer or workstation.
All terminals are equipped with:
12. Bells/Access control. When used with the optional Signal Control Relay (SCR), the TA620 can activate a 10 amp, 110-volt AC circuit or a dry contact relay (with a maximum load of 5 amps, 110 volts AC). This feature is typically used to ring bells, open doors, unlock entry/exit turnstiles, etc. The SCR can be wired as a “normally open” or “normally closed” relay, depending on the door lock/bell hardware requirements. 13. External access readers. The TA620 can interface with an external mag-stripe, barcode, or RF proximity reader to allow remote access. This feature is useful in situations where access to the terminal is not desirable.
•
An internal magnetic stripe reader
•
An RS232 port (RJ11 modular connector).
•
An RS485 port (RJ11 modular connector) if the terminal is a LAN unit or an Ethernet port (RJ45 connector) if the terminal is an Ethernet unit. If the modem option is installed, the modem line plugs into the RS485 port position. The markings RS485 on the terminal are covered with a label that reads MODEM.
•
An accessory port for an optional bar code wand, signal enhancer, and external relay control (for door access and bell ringing).
•
A 25 pin standard parallel port (to attach a parallel printer).
14. Employee Lockout Profiles. This feature eliminates unauthorized overtime by scheduling when employees can use the terminal. You can lockout tardiness, early birds, and force late arrivals and early departures to notify the supervisor in order to punch.
2
3
Page 6
Introduction
Introduction
General Specifications 1.
Case dimensions: 8.7in. (23 cm) wide x 6.1in. (16 cm) high x 2.3in. (6 cm) deep. Clamshell construction of 0.125 in. (3 mm) thick Polycarbonate/ABS injection molded and flame retardant plastic. Reversible mounting bracket and access panel to protect I/O ports.
2.
Microprocessor: Zilog Z-180 operating at 6.144 MHz.
3.
Multi-layer main logic board with internal ground and power planes.
4.
Memory: 64K Read Only Memory (ROM) and 128K Random Access Memory (RAM). RAM is lithium battery backed and expandable to 256K.
5.
On-board Real Time Clock Chip (RTCC) accurate to = 10ppm.
6.
Display: 40 character (2 lines x 20 characters) dot matrix LCD.
7.
Keypad: Alphanumeric Feather Touch membrane design.
8.
Magnetic Card Reader: Track 2 ABA head for reading standard credit card format magnetic stripes.
9.
Internal Bar Code Reader (optional): For visible or infrared 3 of 9 bar codes.
16. External Accessory Port: 6-pin circular DIN connector for an optional bar code wand, signal enhancer, and an external signal control relay box to control various external devices. 17. Power: Wall mount transformer, 9 Volts AC or DC, 500 mA minimum, with secondary plug size 2.1 x 5.5 mm.
10. Port # 1: RS232 using a 6 position (4 contact) RJ11 modular connector. 11. Port # 2: RS485 (LAN)/Modem ports using a RJ11 modular connector or an RJ45 modular connector for Ethernet use. 12. Parallel Port: Standard 25-pin DB connector. 13. Internal Modem (optional): Bell212A (1200bps) and 103 (300bps), CCITT V.22 bis (2400bps), and V.22 (1200bps), asynchronous, licensed for use over public telephone lines. 14. Internal Network Interface Card (NIC) for use on a Local Area Network or Wide Area Network. 15. Internal multi-frequency piezo electric buzzer.
4
5
Page 7
Installation
Chapter 2
Unpacking and Inspection
Installation
Open the shipping cartons and remove the contents. Place the contents on a clean and adequately protected working surface. Inspect the terminal and all accessories for damage. Report any damage or shortages to the shipping company.
Location/Site Requirements
The following items shown in Figure 2-1 should be present:
The TA620 can be installed in any normal office or factory environment. Controlled environments are not required for proper operation of the terminal. However, installing and operating the terminal under adverse conditions may affect its functionality and void the manufacturer’s warranty.
Precautions Do not operate the terminal under the following conditions: •
• • •
Extremely high or low temperature. [Operating temperature range: 32-104 degrees F (0 to 40 C)] [Storage temperature range: 0-158 degrees F (-18 to 70 C)] Extremely high humidity. [Humidity range: 0 to 90% RH non-condensing] Unstable environments (abrupt temperature and/or humidity changes). Exposure to direct sunlight. Areas of high dust concentration.
• •
Areas with chemical fume concentration. Areas with extreme vibration or unstable surfaces.
•
•
Power supply
•
TA620 Data Collection Terminal
•
Configuration badge (Magnetic Badge Encoded with “000000000”)
•
Four (4) mounting screws
•
Installation and Operation Guide
Installation Tools The following tools may be necessary for installation: •
¼” nut driver (t he bit holder for nearly all electric screwdrivers can be substituted.)
•
Flathead screw driver
•
Pencil, pen, or scribe (for marking)
•
Small level (optional)
Maintenance
•
Electric or hand drill
The TA620 does not require any routine or periodic maintenance. However, reasonable care of the terminal will extend its life and ensure proper operation. Avoid spilling liquids on the terminal.
•
Wire cutters (for communication cable installation)
•
Wire strippers (for communication cable installation)
Do not, under any circumstances, attempt to replace the lithium battery in the terminal. Lithium batteries have a very long shelf life and typically do not require replacement. If battery replacement is necessary, qualified personnel must do it.
•
Phillips screw driver (for communication cable terminal connections)
6
7
Page 8
Installation
Installation Installation Overview
Communication Methods Listed below are various communication methods that may be used to communicate with the TA620 Data Collection Terminal. Select the appropriate method, go to the page referenced, and begin the installation process.
To properly install your terminal, follow the recommended installation sequence of events listed below:
Sequence of Events
Local Communications
No.
Task.
Method
Purpose
Page #
1
Serial
For single terminal installations up to 100 feet away.
11
Determine the locations for the terminals. Choose locations based -not only on ease of employee access, but also on the security of the terminal. Also, ensure that the distance from the terminal to the PC does not exceed the maximum length for the desired communication method.
LAN
For single terminal installations over 100 feet away (but less than 4000 feet) and for multiple terminal installations.
12 2
Choose the appropriate communication method and install communications cabling per the applicable diagram. • Serial Communication • LAN Communication • Ethernet Communication • Internal Modem Communication • External Modem Communication • Remote LAN Communication • Ethernet Communication
3
Install the terminal’s wall mount and hang the terminal.
4
Plug the terminal’s power supply into a UL listed surge protector. Failure to include a UL listed surge protector in the installation will void the terminal’s warranty.
5
Connect a serial or parallel printer (if used) to the terminal.
6
Connect any accessories (if used) to the terminal. Accessories include barcode wands/guns, signal enhancers, external slot readers, and signal control relays.
7
Power up the terminal.
8
Install the access panel.
Remote Communication Method
Purpose
Page #
Internal Modem
For single or multiple terminal installations with remote locations using standard telephone lines and direct access extensions.
14
External Modem
For remote communications with terminals not purchased with internal modem option.
17
For remote locations using only one telephone line to communicate with multiple terminals.
18
Remote LAN
Network Communication Met hod
Purpose
Page #
Ethernet 10base-T
For single or multiple terminal installations with local or remote locations via a local area network/wide area network that is capable of supporting static IP addresses.
19
8
9