Field Upgrades and Servicing
Field Upgrades and Servicing
Configure Ethernet: (For Ethernet terminals only)
Chapter 5
•
Swipe the Configuration Badge (00000000)
•
Select option 2 for Ports <Press ENTER>
•
Select option 2 <Press ENTER>
•
Select or enter the baud rate option 3 for 9600 <Press ENTER> (Leave this as the default for Ethernet)
•
Select or enter the TCPIP address <Press ENTER> (Must be a static TCP/IP address)
Field Upgrades And Servicing This chapter provides an explanation on how to perform the following: •
Internal Bar Code Reader Option Installation
•
Signal Control Relay
•
Display Contrast Adjustment
NOTE: When entering IP addresses use the “Out” key to skip over the (.) in an IP address. • •
Select or enter the GATEWAY address <Press ENTER> (This can be obtained from your network administrator) Select or enter the NETMASK VALUE <Press ENTER> (The Network SubNetMask number contains 4 elements (octets) of numbers separated by “.”.The number that needs to be entered is a 2-digit number. To get to this 2-digit number the subnet mask needs to be converted to binary. To determine your NETMASK VALUE, take your SubNetMask, i.e. 255.255.255.000 and convert the 4 octets to binary, which will become 11111111.11111111.11111111.00000000. Next count the zeros from rightto left. There are 8 zeros when counted, this will become your new NETMASK VALUE. Therefore the NETMASK VALUE would be 08. The Ethernet terminal NETMASK can range from 01 to 24.
•
Select or enter the PORT VALUE <Press ENTER> (Default is 10001, must match software setting)
•
Select or enter the BUFFER FLUSH <Press ENTER> (Select default (000), setting not applicable with non-UNIX Operating Systems)
•
Select or enter the TERMINAL TRANSACTION PRINTER TYPE <Press ENTER>
•
•
Select or enter the TRANACTION TIME OUT <Press ENTER> (This controls how long the terminal will restrict between badge swipes. Example: You want to you’re your employees off the terminal for at least 30 minutes for lunch, then set TRANSACTION TIME OUT to 30. Recommended setting is zero (0) to turn this feature off) Select or enter the TERMINAL ID <Press ENTER> (default is 1, select the ID for the terminal, each terminal MUST have a unique ID) NOTE: The terminal MUST be powered down and backup to accept the new TCP/IP settings.
Internal Bar Code Reader This section explains how to install the internal bar code reader option. Once installed, the terminal can either read visible or infrared bar coded badges, depending on the type of bar code reader head installed. NOTE: The terminal will only read visible bar codes if a visible bar code read head is installed. However, an infrared read head is capable of reading both types of bar codes. NOTE: Only a qualified electronic technician should perform this upgrade. PROCEDURE – INTERNAL BAR CODE READER INSTALLATION 1.
Remove the access panel and rear cover from the terminal. Refer to Figure 32. (a)
Remove the hex screw from the terminal. Use the nut driver provided.
(b)
Slide the access panel downward from the terminal.
(c)
Remove three screws from the rear cover of the terminal.
(d)
Position the terminal face and right side up on a clean and adequately protected working surface.
(e)
Brace and hold down the rear cover of the terminal to the surface.
(f)
Separate the front half of the terminal from the rear cover by grabbing and lifting the top of the front half and unlocking latches on the bottom. Lift the front half up level approximately ¼ inch and hold.
Ø
CAUTION: Avoid completely separating the front cover of the terminal from the rear cover of the terminal as there are internal cables connecting the two halves.
(g)
Open the terminal and expose the circuit board by lifting the front half up 90 degrees (as if there were a hinge).
(h)
Reset the front half of the terminal on the rear cover. Ø
42
NOTE: If it is necessary to disconnect the cables that connect the circuit board to the front half of the terminal, note their positions prior to disconnecting them in order to facilitate reattachment.
43
Page 26
Field Upgrades and Servicing
Field Upgrades and Servicing (c)
Turn the reader head so that PC board is in the horizontal position with the “lead wire” on the left.
(d)
Tighten the hex set screw until the bar code reader is locked in place. Use a 1/16” allen wrench. Ø
3.
NOTE: To prevent damage to the bar code reader head, do not over-tighten the hex set screw.
Install the internal bar code reade r assembly in the terminal. Refer to Figure 33. (a)
Position the internal bar code reader assembly on top of the terminal’s mounting pads.
(b)
Align the screw holes on the mounting bracket’s flange with the screw holes on the mounting pads.
(c)
Install two screws.
Figure 32: Rear Cover Removal Ø
2.
CAUTION: To prevent static electricity damage to the terminal’s circuit board and any of the electronic components to be installed, ground your body using grounding strap or bracelet (commercially available) attached to suitable grounding source.
Install the internal bar code read head in the mounting bracket. Ensure that you do not touch the lens of the read head as this will adversely affect its read rate once installed. (a)
Insert the internal bar code reader head in the mounting bracket until fully seated. Ensure that the reader head is inserted through the beveled side of the mounting bracket.
(b)
Position the mounting bracket (with the reader head in it) in your hand so that the hex screw is on top and the beveled side of the bracket is facing you.
44
Figure 33: Internal Bar Code Reader Installation 4.
Connect the internal bar code reader to the terminal’s circuit board. Refer to Figure 34. (a)
Locate jack J7 on the terminal’s circuit board.
(b)
Connect the internal bar code reader’s plug to jack J7. Ø
NOTE: The internal bar code reader’s plug can only attach to jack J7 in one direction. Do not attempt to connect it backwards.
45
Page 27
Field Upgrades and Servicing
Field Upgrades and Servicing Signal Control Relay The Signal Control Relay shown in Figure 35 offers two means by which an external device (door, gate, turnstile, etc.) can be controlled: •
110 VAC outlet circuit (maximum load of 10 A at 110 VAC).
•
Dry Contact (normally open with a maximum load of 5 A at 110 VAC).
Figure 34: Internal Bar Code Reader Circuit Board Connection 5.
Install the rear cover and access panel on the terminal. (a)
Verify that the square nut for the hex head screw has not fallen out of the rear cover. Close the terminal by lowering the top half down 90 degrees and resting it on the rear cover.
(b)
Attach the front half of the terminal to the rear cover of the terminal in the same manner as it was separated in step #1. Ensure that the locking latches on the bottom of the terminal’s front half are properly inserted in the notches on the bottom of the rear cover. Ø
6.
NOTE: To determine if the front half of the terminal is properly attached to the rear cover, try sliding the access panel on and note if it slides on completely.
(c)
Install three screws in the rear cover of the terminal.
(d)
Slide the access panel upward on the terminal.
(e)
Install the hex head screw in the terminal. Use the nut driver provided or any ¼” nut driver.
Figure 35: Signal Control Relay If you are only using the dry contact, the relay’s 110 VAC power cord does not have to be plugged in. However, if the power cord is plugged in, when using a voltmeter, you will find that the meter always reads 110 VAC. This is because the circuit works off of impedance. Using a Y splitter can use the Signal Control Relay with other equipment sharing the same 6pin DIN port on the TA620 terminal, such as a bar code wand. The bar code wand and the Y splitter are both available from your local Time America sales representative. The diagram shown in Figure 36 is a sample representation of how the Signal Control Relay is wired to control a bell and/or door.
Test the internal bar code reader for proper operation. Refer to the diagnostics procedure in Chapter 4. (a)
Test the functionality of the internal bar code reader by performing step #5 in the diagnostic procedure.
(b)
Follow the remaining steps of the diagnostics procedure to properly exit the terminal’s diagnostic mode.
46
47
Page 28
Field Upgrades and Servicing
Field Upgrades and Servicing The examples shown below explain how the Bell/Access direct ional switch on the backside of the Signal Control Relay operates. The switch allows you to direct which output device (dry contact or 110 VAC outlet) is controlled by Bells and which by Access. Legend: •
SSR = Solid State Relay (110 VAC outlet).
•
RELAY
= Normally open dry contact.
•
A
= Operates off the Access.
•
B
= Operates off the Bell.
Example #1: The Bell will activate the SSR and the Relay.
Figure 36: Signal Control Relay Wiring Diagram
SSR
B
A
B
A
RELAY
B
B
A
A
Example #2: The Access signal will activate the SSR and the Bell signal will activate the Relay.
SSR
B
A
B
A
RELAY
B
B
A
A
Example #3: The Bell signal will activate the SSR and the Access signal will activate the Relay.
SSR
B
A
B
A
RELAY
B
B
A
A
Example #4: The Access signal will activate the SSR and the Relay.
48
SSR
B
A
B
A
RELAY
B
B
A
A
49
Page 29
Field Upgrades and Servicing
Field Upgrades and Servicing
Display Contrast Adjustment This section explains how to adjust the contrast of a terminal’s display. NOTE: Only a qualified electronic technician should perform this adjustment. PROCEDURE – DISPLAY CONTRAST ADJUSTMENT 1.
Remove the access panel and rear cover from the terminal. (a)
Remove the hex head screw from the terminal. Use the nut driver provided.
(b)
Slide the access panel downward from the terminal.
(c)
Remove three screws from the rear cover of the terminal.
(d)
Position the terminal face and right side up on a clean and adequately protected working surface.
(e)
Brace and hold down the rear cover of the terminal to the surface.
(f)
Separate the front half of the terminal from the rear cover by grabbing and lifting the top of the front half and unlocking latches on the bottom. Lift the front half up level approximately ¼ inch and hold. Ø
CAUTION: Avoid completely separating the front cover of the terminal from the rear cover of the te rminal as there are internal cables connecting the two halves.
(g)
Open the terminal and expose the circuit board by lifting the front half up 90 degrees (as if there were a hinge).
(h)
Reset the front half of the terminal on the rear cover. Ø
NOTE: If it is necessary to disconnect the cables that attach between the circuit board and the front half of the terminal, note their positions prior to disconnecting them in order to facilitate reattachment.
50
Figure 37: Rear Cover Removal Ø
2.
CAUTION: To prevent static electricity damage to the terminal’s circuit board and any of the electronic components to be installed, ground your body-using wrist grounding bracelets or grounding straps (commercially available) attached to suitable grounding source.
Adjust the contrast of the terminal’s display. Refer to Figure 38. Ø
NOTE: The terminal must be turned on in order to adjust the contrast on the display. Do not disconnect the cable between the terminal’s circuit board and display. (a)
Locate the Display Contrast Potentiometer (DCP) on the terminal’s circuit board.
(b)
Turn on the terminal and position it so that the display is visible.
(c)
Using a small screwdriver, slowly rotate the DCP adjustment, screw clockwise and note the contrast of the terminal’s display. Adjust to suit your requirements.
(d)
Turn off the terminal (remove power) and position it for reassembly.
51
Page 30
Field Upgrades and Servicing
Appendix A
Magnetic Stripe Reader and Card Standard: The TA620 magnetic stripe reader reads ABA Track 2 formatted magnetic stripes through the terminal’s slot. The track 2 standard was developed by the American Bankers Association (ABA) and contains numeric information for the automation of financial transactions. This track of information is also used by systems that require an identification number and a minimum of other control information. For Copies of the standard contact: AMERICAN NATIONAL STANDARDS INSTITUTE 1430 Broadway New York, NY 10018 Telephone: (212) 642-4900 Figure 38: Display Contrast Potentiometer Location 3.
Install the rear cover and access panel on the terminal. (a)
Close the terminal by lowering the top half down 90 degrees and resting it on the rear cover.
(b)
Attach the front half of the terminal to the rear cover in the same manner as it was separated in step #1. Ensure that the locking latches on the bottom of the terminal’s front half are properly inserted in the notches on the bottom of the rear cover. Ø
NOTE: To determine if the front half of the terminal is properly attached to the rear cover, try sliding the access panel on and note if it slides on completely.
(c)
Install three screws in the rear cover of the terminal.
(d)
Slide the access panel upward on the terminal.
(e)
Install the hex head screw in the terminal. Use the nut driver provided.
52
Specifications: 1.
Track 2 is limited to 40 characters; this includes the Start Sentinel (SS), Data, End Sentinel (ES), and Longitudinal Redundancy Check (LRC) areas of the magnetic stripe as shown below. Magnetic Stripe SS
DATA
Hex Code 3b (;)
ES Hex Code 3f (?)
2.
Recording Density is 75 bits per inch.
3.
Character configuration (including Parity Bit) is 5 bits per character.
53
LRC
Page 31
Bar Codes The bar code must be slid through the slot, allowing the quiet zones on the card to be scanned. A smooth scan at a constant speed is important. Typically a fast scan works better then a slow scan.
Appendix B
Bar Codes Bar Code Reader Environmental Specifications: •
Operating and storage temperature:
Minimum bar code card swipe speed: 3 inches per second.
•
Swipe direction: Fully bi-directional
Card Specifications:
[Operating temperature range: 32 degrees to 104 degrees F ( 0- 40 degrees C)] [Storage temperature range: 0 to 158 degrees F (-18 to 70 degrees C)] •
•
Operating and storage humidity: [Operating humidity range: 0% to 90% RH non-condensing] [Storage humidity range: 0% to 95% RH]
Bar code cards must be laminated to reduce wear. The laminate material must allow the required PCS to be maintained. Also, the laminate thickness must not exceed 0.003 inches (0.076 mm) to maintain proper focal length of the bar code from the sensor. •
Background substrate should be white with a matte (not glossy) finish.
•
Background reflectance must be 50% or greater.
General Bar Code Specifications:
•
Card thickness: 0.010 _+ 0.002 inch min./ 0.038 _+ 0.002 inch max.
TA620 Data Collection Terminals with bar code reading capability (internal bar code reader and/or external wand) support ANSI Standard Code 39 (also referred to as “3 of 9”) full ASCII bar codes. All bar codes read by the terminals must meet the encoding standards published in the ANSI Code 39 as follows:
•
Lifetime: 200,000 passes (swipes).
Bar Code Location on Card: Refer to Chapter 3, Figure 3-6.
1.
Narrowest bar and space dimension: 0.0075-inch (0.191 mm) minimum (medium resolution).
•
Distance from the bottom edge of card to bottom of bars: 1/8 inch.
2.
Character density: 4.8 characters per inch (3.7 characters per cm) maximum.
•
Distance from bottom edge of card to center of bars: 3/8 inch.
3.
Height: 1/2 -inch minimum.
•
Distance from both sides of card to sides of bars: ¼ inch.
4.
Characters that may be read: At present, 23 “Code 39” characters maximum.
Bar code Printing Specifications: TA620 Data Collection terminals will support both pre-printed and “on-site” produced bar codes. The “Code 39” bars for these cards may be generated by offset, thermal, dot matrix, full-character impact, and laser printers along with various other different techniques, provided they meet the requirements stated in this specification. When printing regular (visible red) bar codes, the bar color should be black, reflectance value must not exceed 25%, and a carbon based ink should be used. The print contrast (PCS) between the background and bars must be 75% or greater. Ø
NOTE: Infrared bar code readers will not read carbon-based ink. The infrared cover/shield is carbon based and interferes with carbon ink bars.
Voids (White spaces in the bar) and specks (black marks on the background) are permissible only if: 1.
The void or speck fits inside a circle, whose diameter is 0.4 times the nominal width of the narrowest bar or the narrowest space in a bar code symbol.
2.
The void or speck occupies no more than 25% of the area of a circle, whose diameter is 0.8 times the nominal width of the narrowest bar or the narrowest space in a bar code symbol.
Card Read Specifications:
54
55
Page 32
Appendix C
Technical Support Scope: This appendix provides information on how to obtain technical support on any problems that may arise during terminal installation, operation, configuration and upgrading. The policy outlined below has been established by Time America, Inc. to help expedite your inquiry. Policy: If you encounter problems during installation, operation, configuration, or upgrading your terminal and cannot resolve them on your own, contact your LOCAL Time America Service Representative. The service representative has received special factory training in areas of terminal installation, operation, configuration, upgrading, and troubleshooting; and in many cases, can help you solve any problems that may arise. It is important to note that there may be instances when your sales representative cannot immediately answer your questions. In these instances a representative will contact Time America, Inc. via a special dealer support telephone number and will get your questions answered with the assistance of product technicians and/or hardware engineers.
Information Needed Prior To Obtaining Technical Support: Your sales representative will need the following information to help you solve your problem(s): 1.
The model of the data collection terminal you are using.
2.
The serial number of the terminal.
3.
Special or optional features installed in the terminal.
4.
The BIOS version number of the terminal that you are using.
5.
The make and model of the host computer (PC) that you are using.
6.
The operating system that you are running.
7.
What you were attempting to do when the problem occurred?
8.
What you were doing when the problem occurred?
9.
The nature of the problem (What happened?).
10. A description of any error message (s) that appeared on the terminal’s display. 11. Has the problem occurred before? 12. Actions that you have taken to correct the problem on your own.
56