Page 31

Connecting a ca ble 1. Make sure you have the correct cable for the device to which you are connecting. If you use the wrong cable, the PTC may not be able to communicate. 2. Turn off the PTC and the computer or accessory to which you are connecting. ! Do not force a ny connectors together if they do not ma te ea sily; you could da ma ge them.

3. Connect the 15-pin connector on the appropriate cable to the PTC’s micro DB-15 connector. 4. Connect the other end of the cable to the computer or accessory. 5. Turn on the PTC and then turn on the device to which it is connected. 6. Follow the instructions for your application program to communicate.

Disconnecting a ca ble 1. Turn off the PTC. 2. Turn off the attached computer or accessory. ! Pull on the ca ble connector when disconnecting. Pulling on the ca ble ca n brea k the interna l wires.

3. Pull the cable’s connector directly away from the PTC’s micro DB-15 connector. 4. If necessary, disconnect the other end of the cable from the computer or accessory.

Using the optica l communica tion cra dle Refer to the SC-960SL User’s Guide for instructions on using the PTC-960SL with the cra dle.

The PTC-960SL’s optical contacts convert electronic signals inside the PTC into pulses of light that can be detected by the SC-960SL Single-bay Communication Cradle. When the PTC-960SL is placed in the cradle, optical contacts on the cradle sense the pulses of light from the PTC and convert them into electronic signals for

29

Page 32

direct communication to the host computer or, with an external modem, for transmission over telephone lines. Likewise, the cradle can communicate back to the PTC through the optical contacts.

30

Page 33

Repla cing the ba ttery pa ck

10

Use the procedures in this section to remove a weak lithium-ion or nickel-cadmium battery pack from the PTC-960SL and replace it with a new one.

Removing the ba ttery pa ck 1. Turn off the PTC. ! Do not lea ve the PTC without a ba ttery pa ck for longer tha n 20 minutes; a ll da ta a nd progra ms in the PTC’s memory will be lost.

2. With your thumb and index finger, press the battery release buttons on both sides of the handle end cap; then pull the end cap and the attached battery pack out of the handle. See Figure 5. 3. Refer to the “Safety information” section on page 10 for instructions on properly disposing of your lithium-ion or nickel-cadmium battery pack.

Figure 5. Removing the ba ttery pa ck Press the ba ttery relea se buttons (one on ea ch side) a nd pull the ba ttery pa ck out of the ha ndle

31

Page 34

Insta lling a new ba ttery pa ck Refer to Appendix C for ba ttery pa ck pa rt numbers.

Newer versions of the PTC-960SL are shipped with a different nickel-cadmium battery pack than older versions; however, either pack can be used in any PTC-960SL. Lithium-ion battery packs, on the other hand, can be used in only newer versions of the PTC-960SL. A lithium-ion pack will physically not fit into the handle of an older PTC-960SL. 1. Make sure the PTC is off. 2. Line up the end cap/battery pack assembly with the opening in the handle. The curved sides of the end cap allow the battery pack to be inserted in only one way. 3. Slide the end cap/battery pack into the handle until the end cap presses against the body of the handle and the release buttons snap into place. 4. Pull on the end cap to make sure it is locked into place.

32

Page 35

Ma inta ining the PTC-960SL

11

Opera ting conditions The PTC-960SL is designed for use in harsh environments. It can be operated at temperatures between –4 degrees F (–20 degrees C) and 122 degrees F (50 degrees C).

Extended tempera ture units If your PTC-960SL was ordered as an extended temperature unit, it can be used in extremely cold environments, such as those found in walk-in freezers. •

An extended temperature version of the PTC-960SL can be operated at temperatures between –22 and 70 degrees F (–30 to 21 degrees C).

•

The PTC can be operated in environments with a maximum relative humidity of 70% noncondensing.

While the PTC is held by a user, body hea t is tra nsferred to the PTC, preventing freezing of the unit a nd its components.

•

Do not leave the PTC unattended (without being held or operated by a user) in a freezer environment (0 to –22 degrees F/–18 to –30 degrees C) for more than 2 hours.

If the PTC’s ba ttery pa ck freezes, a llow it to wa rm up to a t lea st 65 degrees F (18 degrees C) before recha rging it.

•

Do not leave the PTC’s battery pack unattended in a freezer environment for more than 1 hour as the battery pack will freeze and appear to be “dead.”

Ha ndling the PTC The following information will help to ensure you receive safe, reliable, and trouble-free service from your PTC-960SL. •

Do not point the PTC’s scanner at anyone’s eyes, and do not stare into the laser beam. Permanent eye damage could result. 33

Page 36

•

Do not open the PTC’s case. Only a trained technician can service the parts inside the PTC.

•

If your PTC has an internal radio, do not operate it without the antenna installed.

•

Make sure the PTC is off before connecting or removing any accessories.

•

Make sure all accessories are connected correctly and the correct cables are used.

•

Use only Telxon-approved accessories. Do not attempt to connect any electrical device that is not part of your PTC system to the PTC-960SL.

•

If you store a PTC-960SL containing a lithium-ion or nickel-cadmium battery pack in below-freezing temperatures for more than 1 hour, do not charge the pack until it warms up to room temperature. Charging cold battery packs could damage them.

Storing the PTC •

Do not store the PTC-960SL in temperatures below –40 degrees F (–40 degrees C) or above 167 degrees F (75 degrees C).

•

Do not store the PTC-960SL in a damp or humid environment.

1. Transfer any data stored in the PTC to a host computer or another PTC or print the data. See the manual or instructions for your organization’s application program for directions. 2. Make sure you have a copy of any programs stored in the PTC. 3. Disconnect all accessories from the PTC. 4. Recharge the PTC’s battery pack or replace it with a charged pack.

34

Page 37

5. Pack the PTC in the original packing material or in a padded box and put it in a safe place, away from dust, dirt, humidity, and excessive cold. 6. Charge the PTC’s battery pack every two months.

Clea ning the PTC ! Be ca reful not to scra tch the sca nner lens when you clea n it. Scra tches ca n reduce the sca nner’s effectiveness.

Equipment required:

! Do not soa k the cloth a nd do not spra y or pour clea ning liquids directly onto the PTC.

To clean the PTC, slightly moisten a soft, clean, lint-free cloth with a mild, nonabrasive cleaner and wipe the outside surfaces. Do not use a paper towel.

•

A soft, lint-free cloth

•

A nonabrasive liquid cleaner such as Windex

If the PTC becomes extremely dirty or if liquids, dirt, or other foreign materials get inside the case, contact your Telxon service representative.

Servicing the PTC Do not attempt to service the PTC. Only a trained Telxon technician may service the PTC. Follow the procedure set up by your organization to have the PTC serviced properly.

35

Page 38

Troubleshooting

12

If you experience any of the problems in this section, follow the instructions provided.

The PTC does not turn on •

Charge or replace the lithium-ion or nickelcadmium battery pack.

•

Contact your Telxon service representative.

The la ser sca nner does not rea d a la bel See Appendix B for recommended sca nning dista nces.

See pa ge 35 for instructions.

•

Make sure the bar-code label you are trying to scan is one of the bar-code types your PTC is programmed to recognize.

•

Move the laser scanner closer to or farther away from the bar-code label. You may not be scanning at the correct distance.

•

Change the angle of the laser scanner to the bar-code label. You may be too far above or below the bar-code label or too far to the side to scan properly.

•

Clean the scanner lens.

•

The PTC’s application program may not support scanned data at this particular field. Consult the documentation for the PTC’s application program to determine when the scanner and trigger are enabled.

•

Point the scanner at a blank surface and press the scanner trigger. Look for the scanning line or aiming dot that appears on the blank surface when the scanner is operating. If no scanning line or aiming dot appears, follow your organization’s procedure to have the scanner serviced. 36

Page 39

Your ra dio fa ils to esta blish conta ct •

Change your location by a few feet and transmit again.

•

Make sure the antenna is securely attached.

•

Recharge or replace the PTC’s lithium-ion or nickel-cadmium battery pack.

•

Make sure the receiving equipment is turned on and is properly connected to the host computer.

•

If the PTC still does not establish contact, follow your organization’s procedure to have the PTC serviced.

Other problems If you experience any other problems with your PTC-960SL that you cannot solve, notify your Telxon service representative or contact the Telxon Customer Support Center at 1-800-800-8010.

37

Page 40

Appendix

A

Specifica tions Communica tion a nd I/O Serial:

RS-232 via micro DB-15 connector; 300 to 38,400 baud

Optical:

Via optical contacts and SC-960SL

Internal radio:

Optional 900-MHz or 2.4-GHz direct-sequence spread spectrum radio or 2.4-GHz frequencyhopping spread spectrum radio

Radio data rates 900-MHz DS spread spectrum: 2.4-GHz DS spread spectrum: 2.4-GHz FH spread spectrum:

344 kbps 2 Mbps 1 Mbps

Displa y Type:

FSTN monochrome liquid crystal display

Text mode:

8 or 16 lines with 16 or 21 characters; double-height character option available

Graphics mode:

128 x 128-pixel resolution

Pixel size:

0.015 x 0.014 in/0.38 x 0.36 mm

Active area:

2.1 x 1.9 in/53.3 x 48.3 mm

Backlight:

Electro-luminescent (EL) panel

38