Page 21

Pa rts

6

Figures 1 through 3 on the following pages show and describe the external parts of the PTC-960SL. The parts listed below are internal and, therefore, are not shown in any of the figures.

Fla sh EPROM A flash EPROM is an electronic component installed inside the PTC. It contains the PTC’s data collection program and determines the PTC’s key functions, the display prompts and messages, and how and when the PTC prints or transmits data. If your PTC has an internal radio, a second flash EPROM holds the program that controls the radio. For deta ils on era sing a nd reprogra mming fla sh EPROMs, refer to the Guide to the Flash Utilities (TCAL or MS-DOS Version).

Flash EPROMs can be erased and reprogrammed while they are inside the PTC. First, the PTC must be connected to a host computer, via a cable or by being placed in an optical communication cradle. Then, using software in the PTC’s operating system, you can erase the flash EPROMs and reprogram them with a new program from the host computer.

Ra dio (optiona l) Your PTC’s a pplica tion progra m controls the ra dio. Refer to your a pplica tion’s ma nua l for deta ils.

The PTC-960SL can be equipped with a 900-MHz or 2.4-GHz direct-sequence spread spectrum radio or with a 2.4-GHz frequency-hopping spread spectrum radio. Each radio allows the PTC to interactively communicate in real-time with a host computer on a radio-based local area network. Spread spectrum provides secure, interference-free communication and does not require a license for operation.

19

Page 22

Figure 1. The PTC-960SL (top, front, a nd side view)

1. Antenna connector

2. Keyboa rd

4. Micro DB-15 connector

3. Wrist stra p connector 1. If your PTC ha s a n interna l ra dio, a n a ntenna screws into this connector. Otherwise, the connector is sea led with a pla stic plug. The a ntenna sends a nd receives ra dio tra nsmissions, a llowing the PTC to communica te with a host computer. The a ntenna must be a tta ched to the PTC before the unit ca n be used. 2. The PTC-960SL’s sta nda rd keyboa rd ha s 45 keys. An optiona l 28-key keyboa rd is a lso a va ila ble. Both keyboa rds ha ve two different types of keys: da ta keys a nd function keys. Da ta keys a re the letter a nd number keys, A-Z a nd 0-9. You use them to type da ta into the PTC. Function keys include the F1-F4, ENTER/YES, a nd SEND keys. They a re used to perform a specia l procedure or function. For exa mple, you ma y use the SEND function key to tra nsmit da ta to the host computer. ENTER/YES key - How you use this key depends on your a pplica tion. Usua lly you press this key to tell the a pplica tion tha t you ha ve finished typing da ta , ha ve finished a n opera tion, or wa nt the PTC to begin a n opera tion, such a s sending da ta to the host computer. ON/OFF key - Pressing this key turns the PTC on or off. SHIFT key - On a 45-key keyboa rd, the SHIFT key a ctiva tes only the function keys la beled on the overla y. The numeric keys a re a lwa ys a va ila ble. On a 28-key keyboa rd, the SHIFT key shifts between the numeric a nd a lpha betic keyboa rd a nd a lso a ctiva tes some of the function keys your a pplica tion uses. 3. A looped wrist stra p a tta ches to this connector. Put your ha nd through the wrist stra p a nd use it to prevent the PTC from fa lling if you a ccidently let go of it. 4. This 15-pin connector connects the PTC via ca ble to a host computer or to sta nda rd seria l devices such a s printers a nd modems. It ca n a lso be used with a power module to recha rge the PTC’s lithium-ion or nickel-ca dmium ba ttery pa ck. Refer to Appendix C for ca ble pa rt numbers.

20

Page 23

Figure 2. The PTC-960SL (top, front, a nd side view) 1. Displa y screen 2. LEDs

3. Control buttons

1. The liquid crysta l displa y (LCD) screen shows the informa tion you type or sca n into the PTC a s well a s messa ges from the PTC or host computer. The screen ca n show 8 or 16 lines of informa tion with 16 or 21 cha ra cters ea ch. Your screen ma y a lso be a ble to displa y gra phics. 2. These four light-emitting diodes (LEDs) provide informa tion on the PTC’s sta tus. Ba tt - This red LED glows when the PTC’s ba ttery pa ck is running out of power. A low-ba ttery messa ge ma y a lso displa y on the PTC’s screen. Immedia tely stop wha t you a re doing, sa ve a ny da ta you ha ve entered, a nd recha rge or repla ce the PTC’s ba ttery pa ck whenever this LED lights. Func - This red LED glows when the FUNC key is pressed. Chg - This red LED glows when the PTC’s ba ttery pa ck is being recha rged. Sca n - This LED glows red while the PTC’s interna l la ser sca nner is a ctive. It glows green when the sca nner ha s successfully rea d a ba r code. 3. These three buttons control the PTC’s displa y screen. The Decrea se Contra st button decrea ses screen contra st in steps until the screen rea ches minimum contra st.* The Increa se Contra st button increa ses screen contra st in steps until the screen rea ches ma ximum contra st.* The Ba cklight button turns the screen’s ba cklight on or off. * Repea tedly pressing either the Decrea se or Increa se Contra st button will loop the PTC’s displa y screen through a ll 16 contra st settings, eventua lly returning to the first setting.

21

Page 24

Figure 3. The PTC-960SL (bottom view) 6. Sca nner lens

1. Optica l conta cts 5. Sca nner trigger (built into ha ndle) 4. Ha ndle 3. Ba ttery relea se button

2. End ca p/ba ttery pa ck a ssembly

1. These four conta cts (two on ea ch side) a llow the PTC to communica te with a host computer through a n optiona l optica l communica tion cra dle. Instea d of sending da ta in the form of electronic signa ls through the micro DB-15 connector, the PTC sends the da ta in the form of pulses of light to simila r conta cts on the cra dle. Then the cra dle converts the pulses of light into electronic signa ls a nd tra nsmits them to the host computer. The cra dle ca n a lso send da ta to the PTC via the optica l conta cts. Refer to the SC-960SL User’s Guide for instructions on using the cra dle. 2. The PTC-960SL is powered by a lithium-ion or nickel-ca dmium ba ttery pa ck, which is inserted into the PTC’s ha ndle. The PTC ha ndle end ca p a nd the ba ttery pa ck a re combined in a single module. Removing the end ca p a lso removes the ba ttery pa ck. When the ba ttery pa ck is repla ced, the entire module is repla ced with a new one. In genera l, a lithium-ion ba ttery pa ck doubles the run time of the PTC (in compa rison to a nickel-ca dmium ba ttery pa ck). 3. Pressing these buttons (one on ea ch side of the PTC’s end ca p) relea ses the ba ttery pa ck, a llowing it to be removed from the PTC. 4. The ha ndle a llows you to hold the PTC a nd a im the built-in la ser sca nner when you a re sca nning ba r codes. It a lso conta ins the PTC’s lithium-ion or nickel-ca dmium ba ttery pa ck. 5. Pressing this trigger, which is built into the rubber skin of the ha ndle, a ctiva tes the PTC’s interna l la ser sca nner, a llowing you to sca n ba r codes. Note: Your a pplica tion progra m ma y not support sca nned da ta for a ll fields. Consult the documenta tion for your a pplica tion to determine when the sca nner a nd trigger a re ena bled. 6. The la ser light emitted from the PTC’s interna l la ser sca nner exits the unit through this lens. $ Do not sta re into the la ser bea m or point the sca nner a t a nyone’s eyes while the sca nner is a ctive; perma nent eye da ma ge could result.

22

Page 25

Fea tures

7

Autodiscrimina tion between ba r codes See Appendix B for a list of the ba r-code types your PTC is progra mmed to rea d.

Your PTC-960SL’s application program can read and automatically discriminate between up to six different bar-code types.

Automa tic off To conserve battery power, the PTC-960SL automatically turns itself off after approximately 1 minute of inactivity. The exact length of time depends on your application program.

Automa tic return a t on When you turn off the PTC-960SL (or when the PTC turns itself off), it remembers where it was in the application. Then when you turn the PTC back on, it returns to that same point in the application. You do not need to review what you have done or perform any other start-up function to find your place.

Ba cklight The screen’s backlight lights up the screen and makes information on the display readable in dark or dim conditions. Pressing the Backlight button turns the backlight on or off.

23

Page 26

Ba ckup ba ttery ! Do not store the PTC-960SL for over two months without cha rging or repla cing the ba ttery pa ck. Both the ma in ba ttery a nd the ba ckup ba ttery will dra in, a nd a ny da ta or progra ms in the PTC’s memory will be lost.

The PTC-960SL’s built-in backup battery provides enough power to protect data stored in the PTC’s memory when the battery pack is being replaced or if it runs out of power. The backup battery system provides approximately 20 minutes of protection when the battery pack is removed.

Beeper The PTC’s beeper is used by the PTC and your application to warn you of problems or to prompt you to take an action. For example, if your application program has temporarily turned off a key, the PTC will beep if you press that key. Depending on your organization’s application software, you may be able to control the beeper’s volume. See the manual or instructions provided by your organization.

Clock The PTC’s clock ca n be set using the MS-DOS TIME a nd DATE comma nds.

The PTC-960SL has a built-in clock that keeps track of the date (month, day, year, and day of the week) and the time (hours, minutes, seconds, and tenths of seconds). The clock operates continuously. How the clock is used depends on your application program. For example, the PTC can use the clock to show the date and time on its screen or to time-stamp a file.

Communica tion The PTC-960SL is capable of communicating with a host computer through its internal radio, through an optional optical communication cradle, or by being connected directly via a cable. See the manual or instructions provided by your organization for the proper communication procedure for your application.

24

Page 27

Memory The PTC-960SL has two types of memory: read-only memory (ROM) and random access memory (RAM). The PTC’s ROM is contained on an electronic chip called a flash EPROM, which can be reprogrammed while inside the PTC. It is used to store the PTC’s operating system and application program. RAM is used to store data entered into the PTC and application configuration settings. Data stored in RAM can be easily read, written, and changed. It is also volatile. All data in RAM will be lost if the PTC’s battery pack and backup battery run out of power. The amount of memory in your PTC determines how much data you can enter before you have to send it to a host computer or print it. Various amounts of memory are available from Telxon, and the amount actually installed in your PTC has been determined by your organization’s needs.

25

Page 28

Sca nning ba r-code la bels

8

The PTC-960SL is programmed to automatically recognize, read, and discriminate between up to six bar-code types. See the information provided by your organization and Appendix B for a list of the bar-code types your PTC is programmed to read. PSC sca nners a re preconfigured for the ma rker bea m fea ture a t the fa ctory, but Symbol sca nners must be configured for this fea ture through the PTC’s a pplica tion progra m. If your PTC conta ins a Symbol sca nner, refer to the RAMSaver Application Development Manual for instructions on ena bling the ma rker bea m fea ture.

When the PTC’s scanner trigger is pressed, the PTC usually emits a horizontal scanning line and immediately initiates the scanning process. However, the PTC-960SL’s laser scanner features a marker beam option that can assist you by temporarily providing a highly visible marker. With the marker beam feature enabled, the PTC emits a bright red dot that can be used to aim the laser and center it over a bar code. This feature is especially useful for outdoor or long-range scanning applications, which typically require additional time to aim the laser beam. Follow this procedure to scan bar-code labels with the PTC-960SL’s built-in laser scanner.

$ Do not sta re into the PTC’s la ser bea m or point the sca nner a t a nyone’s eyes. Eye da ma ge could result.

1. Point the PTC-960SL at the label to be scanned. The scanner can be at an angle to the label. The maximum distance from the scanner lens to the label depends on the size of the label being scanned and the type of laser that was selected by your organization. See Appendix B for the recommended scanning distance.

26

Page 29

Figure 4. Sca nning ba r-code la bels

Ma ke sure the sca n line extends beyond both sides of the ba r code

Your a pplica tion progra m ma y not support sca nned da ta for a ll fields. Consult the documenta tion for your a pplica tion to determine when the sca nner a nd trigger a re ena bled.

2. Press and hold the trigger on the PTC’s handle to start scanning. The Scan LED glows red while the scanner is active. If the scanner’s marker beam feature is enabled, quickly center the aiming dot over the bar code. 3. Watch the line of light made by the scanner as it scans the bar code.

If the sca n is successful, the Sca n LED glows green, a nd the PTC beeps.

4. Hold the PTC so that the scanning line is perpendicular to the bars in the bar-code label. Also, make sure that the line passes over all of the bars. See Figure 4.

27

Page 30

Communica ting da ta

9

The PTC-960SL is able to communicate with other PTCs, host computers, and external accessories such as printers. It can both send and receive data and instructions. Communication is controlled by your organization’s application program. See the manual or instructions provided by your organization for details on conducting communication sessions. The PTC-960SL is designed to use its internal radio as its primary means of communicating with a host computer, but it can also communicate by being connected directly to the host computer via cable or by being placed in an optical communication cradle that is connected to the host computer. Accessories such as printers are connected to the PTC with a cable.

Using the ra dio ! If your PTC conta ins a ra dio, do not turn on the PTC or a ttempt to tra nsmit da ta unless the a ntenna is a tta ched; otherwise, the ra dio ma y be da ma ged. Refer to Appendix C for ca ble pa rt numbers.

All radio communication is controlled by your organization’s application program. See the instructions provided with the program for information.

Using the micro DB-15 connector To connect the PTC-960SL to another PTC, host computer, or accessory via the micro DB-15 connector, you need the correct cable. Different cables may be required depending on what you are connecting the PTC to. See the manual or instructions your organization supplies for your application program.

28