The text of a manual · part 6 of 16
PTC-1800 Product Reference Guide, pages 37 to 42
Pages 37 to 42 of 108: Operating the PTC-1800; Data application
The original document is the PDF (633 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Telxon PTC-1800
Page 37
Chapter
8
Operating the PTC-1800 Turning on the PTC-1800 To turn on the PTC-1800 initially, press the On/Off key. If the PTC-1800 is in suspend, you can wake it by pressing the On/Off key or one of the Scan keys. If the PTC-1800 is in ship mode, you cold boot it by pressing the On/Off key.
Turning off the PTC-1800 Refer to the “Power management” section in Chapter 7 for more information.
Press the On/Off key to suspend the PTC-1800. Suspending the PTC-1800 saves power and allows the unit to resume operation exactly where it left off. It also terminates any active telephone call(s). Be sure to save all files as a precaution before suspending. In addition, the PTC-1800 suspends automatically if it has not been used for approximately 1 min.
PTC-1800 Product Reference Guide
27
Page 38
Chapter 3 Configuring TN-3270/5250
28
PTC-1800 Product Reference Guide
Page 39
Chapter
9
Data application Overview Your organization has developed an application to meet its data collection needs. This application allows the PTC-1800 to collect, store, and transmit data to a host device.
Using the application Follow the instructions below to begin using the data application. Consult the information provided by your supervisor for details on your organization's data application. 1. Press the Data key to activate your organization's data application. 2. Use the PTC-1800 to enter, store, and transmit data. See the “Entering data,” “Storing data,” and “Communicating data” sections on the following pages for information.
Entering data Data may be entered into the PTC-1800 via the following methods:
PTC-1800 Product Reference Guide
•
Keyboard,
•
Laser scanner,
•
Internal radio (optional).
29
Page 40
Chapter 3 Configuring TN-3270/5250
Via the keyboard The PTC-1800's keyboard can be used to enter data. See Chapter 6 for a description of each of the PTC-1800's keys. 1. Press the data keys to enter alphabetical or numeric data into the PTC-1800. 2. Press the Send key.
Through a laser scanner A bar code is a series of vertical bars and spaces used to encode information in a machine-readable form. They are used on nearly every item in business today.
Data can also be entered with the PTC-1800's laser scanner. When you scan a 1D bar code, the PTC-1800 is programmed to read, while the PTC-1800 and scanner interpret the data and store it in the PTC-1800's memory.
Bar-code types See the information provided by your supervisor for the specific bar-code types your PTC-1800 has been programmed to recognize (several of those listed above).
If your PTC-1800 contains an internal laser scanner, that can scan and interpret these bar codes: • BC412
• EAN-8
• Codabar
• EAN-13
• Code 4
• Industrial 2 of 5
• Code 5
• Interleaved 2 of 5
• Code 11
• MSI/Plessey
• Code 39
• UPC-A
• Code 93
• UPC-E
• Code 128
• UPC/EAN 2 & 5 digit add-on
30
PTC-1800 Product Reference Guide
Page 41
Storing data
Scanning procedure ! Do not stare into the laser beam or point the scanner at anyone's eyes. You could cause permanent eye damage. The maximum distance from the window on the nose of the scanner to the label depends on the range of the scanner and on the size of the label being scanned. Table 5 provides a list of recommended scanning distances.
Follow this procedure to scan bar-code labels with the PTC-1800's internal laser scanner. 1. Point the laser scanner at the label to be scanned. The scanner can be at an angle to the label. Table 5. Recommended scanning distances
Size of label
SE-900 scanner (inches/centimeters)
5 MIL
2 to 5 in./5.1 to 12.7 cm
7.5 MIL
1 to 7 in./2.5 to 17.8 cm
10 MIL
1.5 to 10 in./3.8 to 25.4 cm
20 MIL
Up to 15 in./38.1 cm
40 MIL
Up to 22 in./55.9 cm
55 MIL
Up to 29 in./73.7 cm
The Status LED glows amber when the scanner is scanning a bar code.
2. Press one of the PTC-1800's Scan keys to start scanning.
The PTC-1800 beeps if the scan is successful.
3. Watch the line of light made by the scanner as it scans the bar code. The line must pass over all of the bars on the label for the bar code to be read.
Via an optional internal radio Another method of entering data is via the PTC1800's optional internal local area network (LAN) radio. The radio transmits and receives information to/from other radio devices on the wireless network.
Storing data Data entered into the PTC-1800 may be stored in the PTC-1800's RAM or on the internal solid-state hard disk drive.
PTC-1800 Product Reference Guide
31
Page 42
Chapter 3 Configuring TN-3270/5250
Communicating data After collecting the data, the PTC-1800 can transmit it to a host device for processing or for sending it to a printer. The PTC-1800 can transmit data via its IrDA port or through its optional internal LAN radio.
Using the IrDA port Introduction The PTC-1800's IrDA port allows the PTC-1800 to communicate via pulses of light to and from other IrDA-compliant devices, such as printers and host systems.
Procedure Follow the instructions below to use the PTC-1800's IrDA port. 1. Line up the PTC-1800 and the other IrDAcompliant device so that their IrDA ports are within 2 to 3 ft (.6 to .9 m) of one another. 2. Follow the instructions or manual provided by your supervisor for the proper communication procedure to follow.
Using the radio All radio communication is controlled by your PTC-1800's application program. See the instructions provided with the program for information.
32
PTC-1800 Product Reference Guide