Page 87

Chapter

15

Troubleshooting Getting started As a first step in resolving problems, consider the points in this section.

PTC-1800 Product Reference Guide

•

As soon as an error occurs, stop what you are doing. Write down what the system is doing and what actions you took immediately before the problem occurred.

•

If any messages display on the screen, look them up in your software manuals.

•

Does the Status LED glow? Does it stay on or blink? See Appendix C for an explanation of the PTC-1800's Status LED codes.

•

Do any icons appear on the PTC-1800's display screen? See Appendix C for an explanation of the display icons.

•

Has the speaker sounded? How many times and in what pattern? Do the beeps seem to be related to anything you are doing?

•

Is the PTC-1800 making any unusual noises?

•

Confirm that the PTC-1800 has been set up properly.

•

Can you run some applications but not others? Check that your software is properly installed and that the application program and data files are not corrupted.

•

If the PTC-1800 locks up (the application stops responding), reboot the PTC-1800. See Chapter 16 for instructions.

77

Page 88

Chapter 3 Configuring TN-3270/5250

Common solutions If you experience any of the problems listed in the table below, follow the instructions provided. Table 12. Common solutions

78

Problem

Action

The PTC-1800 does not turn on.

•

Charge or replace the battery pack.

•

Reboot the PTC-1800, following the instructions in Chapter 16.

•

If the PTC-1800 still does not operate, follow your organization’s procedure to have the PTC-1800 serviced.

The PTC-1800’s screen is slow to refresh.

•

Wait until the PTC-1800 warms up to room temperature if it has been stored or used in the cold.

The battery pack runs down rapidly after being charged.

•

Disconnect the AC or vehicle adapter from the PTC-1800.

•

Contact your Symbol service representative if the problem continues.

The battery pack does not hold a full charge after being recharged.

•

The battery pack may be faulty or worn out, particularly if it is old. Replace it with a new one.

PTC-1800 Product Reference Guide

Page 89

Common solutions

Problem

Action

The radio fails to establish contact.

•

Change you location by a few feet and transmit again.

•

Recharge or replace the PTC’s battery pack.

•

Make sure the receiving equipment is turned on and is properly connected to the host computer.

•

If the PTC still does not establish contact, follow your organization’s procedure to have the PTC serviced.

•

Check that the radio type matches your access point radio system.

•

Check the antenna.

•

Validate that the telephones are all using the same vocoder (e.g. G.711).

PTC-1800 Product Reference Guide

79

Page 90

Chapter 3 Configuring TN-3270/5250

Problem

Action

The laser scanner does not read a label.

•

Move the laser scanner closer to or farther away from the bar-code label. You may not be scanning at the correct distance.

•

Change the angle of the laser scanner to the bar-code label. The scanner may be too far above or below the bar-code label or too far to the side to scan properly.

•

Clean the scanner’s lens.

•

Point the scanner at a blank surface and press one of the Scan keys. Look for the scanning line that appears on the blank surface when the scanner is operating. If no scanning line appears, follow your organization’s procedure to have the scanner serviced.

•

Make sure the bar-code label you are trying to scan is one of the bar-code types that your PTC-1800 has been programmed to recognize.

•

The PTC-1800’s application program may not support scanned data at this particular field. Consult the documentation for the PTC-1800’s application program to determine when the scanner and Scan keys are enabled.

•

Reboot the PTC-1800, following the instructions in Chapter 16.

•

Reset the PTC-1800, following the instructions in Chapter 16.

•

Follow your organization’s procedure to have the PTC-1800 serviced.

Your application locks up.

80

PTC-1800 Product Reference Guide

Page 91

Getting help

Getting help If you are unable to correct a problem by following the troubleshooting tips in this chapter, follow the instructions below for assistance.

Sources of information Try the following before contacting Symbol: •

Review the other documentation available for the PTC-1800.

•

Review the troubleshooting sections in your Microsoft manuals.

•

Review the documentation for your application.

Who to contact If reviewing the above sources of information does not improve the PTC-1800's performance, notify the following Symbol personnel:

PTC-1800 Product Reference Guide

•

Your Symbol service representative.

•

The Symbol Customer Support Center at 1-800-653-5350.

81