Page 15
Chapter
3
Scope of the manual This manual provides general information on the PTC-960SL-III’s parts, features, and accessories. It also explains how to operate and maintain the PTC. This manual does not include the specific operating instructions for your organization’s unique data collection program. Operating instructions and training should be available from your organization.
Document conventions The following conventions are used throughout this manual.
Warnings
Warnings indicate potential bodily injury or death. They are set off in the left-hand columns of this manual by the following symbol: .
Cautions Cautions indicate potential damage to equipment. They are set off in the left-hand columns of this manual by the following symbol: !.
Notes Notes provide supplementary information. They are set off in the left-hand columns of this manual and are not preceded by a symbol.
PTC-960SL-III User’s Guide
5
Page 16
Chapter 3 Configuring TN-3270/5250
6
PTC-960SL-III User’s Guide
Page 17
Chapter
4
Overview of the PTC-960SL-III The Symbol PTC-960SL-III is a battery-powered, hand-held computer used to collect, store, and transmit data. It has a built-in laser scanner and may contain a spread spectrum radio. The PTC-960SL-III automates data collection procedures and is custom programmed to handle efficiently your organization’s unique data collection jobs. The PTC runs a program specially designed to collect data for your organization. This program leads the user through the data collection procedure with a series of display messages, prompts, and beeps. Messages tell the user when you make an error and provide information on the program or the PTC’s status. Prompts and beeps tell the user when to enter data, what type of data to enter, and when certain operations are complete. The PTC-960SL-III is extremely durable. It is designed to withstand the low atmospheric pressure at high altitudes, a 4 ft (1.2 m) drop to concrete, vibration, shock, and dust. See the section titled "Extended temperature units," starting on page 33, for more information on extended temperature versions.
PTC-960SL-III User’s Guide
An extended temperature version of the PTC-960SL-III is designed for use in extremely cold environments, such as those found in walk-in freezers. This optional unit may be operated in temperatures as low as –22° F (–30° C).
7
Page 18
Chapter 3 Configuring TN-3270/5250
Entering data Entering data into the PTC-960SL-III is easy. Data can be keyed in through the keyboard or bar codes can be scanned with the internal laser scanner. Additionally, data may be received through an optional internal direct-sequence or frequencyhopping spread spectrum radio.
Through the keyboard Entering data through the keyboard is similar to operating a calculator. As the user presses the data keys, the corresponding numbers or letters appear on the screen. Pressing the ENTER key stores data in the PTC’s memory.
With the internal laser scanner or imager A bar code is a series of vertical bars and spaces used to encode information in a machine-readable form. They are used on nearly every item in business today.
A second method of entering data is with the PTC’s internal laser scanner or imager. When scanning a bar code that the PTC is programmed to read, the PTC and scanner interpret the data and store them in the PTC’s memory.
Via the radio Refer to the sections titled "Radio (optional)," on page 15, and "Using the radio," on page 27, for information on radio communication.
Storing data Data entered into the PTC may be stored in files in the PTC’s memory.
8
PTC-960SL-III User’s Guide
Page 19
Communicating data
Each file holds a separate group of application-related data. For example, a PTC used to collect many types of data (sales orders, inventory changes, and employee hours) would store all data relating to sales orders in one file, all data relating to inventory changes in another, and all data relating to employee hours in still another.
Communicating data After collecting the data, the PTC must either transmit them to a host computer for processing or send them to a printer, or both, to make them useful to you and your organization. The PTC-960SL-III can transmit data through its internal radio, via an optional communication cradle, or by being connected by cable to a host computer, printer, or other accessory. Once the host computer receives the data from the PTC, it uses that data to update its master files and records. In some cases, the host computer may even transmit data back to the PTC, requesting the user of the PTC to perform a new task.
PTC-960SL-III User’s Guide
9
Page 20
Chapter 3 Configuring TN-3270/5250
10
PTC-960SL-III User’s Guide