For the Teklogix NEO PX750
Page 322
Appendix C: Bar Code Settings MSI Plessey
Check Digit Verification When enabled, this parameter checks the integrity of a symbol to ensure it complies with a specified algorithm – either USS (Uniform Symbology Specification) or OPCC (Optical Product Code Council). Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Set Length L1, Set Length L2, and Set Length L3 Lengths for “Codabar” can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner. Length Mode You can choose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length. Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.12
MSI Plessey Enabled Set this parameter to on to enable “MSI”. Enable Plessy Set this parameter to on to enable “Plessy”. Check Digit Verification The available options for this parameter are MOD 10 Check and Double MOD 10 Check. This parameter uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted.
C-28
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 323
Appendix C: Bar Code Settings Code 11
Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Plessy Transmit Check Digit If the check digit is to be transmitted with the Plessy data, this parameter must be enabled. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Plessy Minimum Length Minimum lengths for the Plessy bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.13
Code 11 Enabled Set this parameter to on to enable “Code 11”. Check Digit Verification The available options for this parameter are MOD 10 Check and Double MOD 10 Check.This parameter uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s).
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
C-29
Page 324
Appendix C: Bar Code Settings Interleaved 2 of 5
Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.14
Interleaved 2 of 5 Enabled Set this parameter to on to enable “Interleaved 2 of 5”. Reading Range This parameter determines the reading distance from which a bar code can be successfully scanned. The default setting, Extended, allows for increased reading distance. Check Digit Verification The available options for this parameter are Disabled, MOD 10 Check and French CIP. “Check Digit Verification” uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. Note: French CIP (French pharmaceutical) is only used with bar codes containing 7 characters. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Set Length L1, Set Length L2, and Set Length L3 Lengths for “Interleaved 2 of 5” can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner. Length Mode You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length. Length Restriction Refer to “Length Restriction” on page C-8 for details.
C-30
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 325
Appendix C: Bar Code Settings Matrix 2 of 5
Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.15
Matrix 2 of 5 Enabled Set this parameter to on to enable “Matrix 2 of 5”. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page 9 for details.
C.3.16 Discrete 2 of 5 Enabled Set this parameter to on to enable “Discrete 2 of 5”. Standard 2 of 5 Format This parameter allows you to choose a standard format – either Identic on (6 start/stop bars) or Computer Identics (4 start/stop bars). Check Digit Verification The available options for this parameter are Disabled and MOD 10 Check. “Check Digit Verification” uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Set Length L1, Set Length L2, and Set Length L3 Lengths for “Discrete 2 of 5” can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
C-31
Page 326
Appendix C: Bar Code Settings Telepen
Double-tapping on these parameters displays dialog boxes where you can define the code length that will be recognized by your scanner. Length Mode You can chose to set L1 as Minimum Length or L1,L2,L3 as Fixed Length. Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.17
Telepen Enabled Set this parameter to on to enable “Telepen”. Format This parameter allows you to set the bar code character format to either ASCII or Numeric. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.18 GS1 DataBar All GS1 DataBar bar codes encode a GTIN-12 or GTIN-13 in a 14-digit data structure. In order to make the GTIN-12 or GTIN-13 a 14-digit data structure, a leading zero or zeros is filled to the left of the GTIN. Enable GS1 DataBar Omni, Expanded & Limited GS1 DataBar Omni and GS1 DataBar Expanded have omnidirectional scanning capability. GS1 DataBar Limited can only be scanned by a linear hand-held scanning device. They C-32
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 327
Appendix C: Bar Code Settings Composite cannot be scanned by omnidirectional scanners. Each of these options can be turned on or off depending on the scanner installed in your hand-held. Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.19
Composite Important: To successfully read this type of bar code, the two types of symbologies included in a composite bar code must be enabled. In addition, “Center Bar Code Only” must be disabled. A composite symbol includes multi-row 2D components making it compatible with linear and area CCD scanners along with linear and rastering laser scanners. The options available for this parameter represent multi-level components of a composite symbol. Enable CC-C and Enable CC-AB To activate these components, set these parameters to on. Linear Transmission Only When ‘Linear Transmission Only’ is enabled, only the linear code portion of the composite bar code is transmitted when scanned. UPC-EAN Composite Message This option allows you to choose how UPC-EAN shared bar codes are transmitted: Always Linked, Never Linked or Auto-discriminate.
C.3.20
TLC-39 Enable This composite component integrates MicroPDF417 with the linear Code 39 symbol. Setting this parameter to on enables this parameter.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
C-33
Page 328
Appendix C: Bar Code Settings PDF-417
Linear Transmission Only When “Linear Transmission Only” is enabled, only the linear portion of the composite bar code is transmitted when scanned. Security Level This parameter is used to differentiate between TLC-39 and standard Code 39. Tapping on “Security Level” displays a dialog box in which you can assign a value from 0 to 100. The higher the value assigned, the lower the decode rate. Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.21
PDF-417 Enabled Set this parameter to on to enable “PDF-417”. Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.22
Micro PDF-417 Enabled Set this parameter to on to enable “Micro PDF-417”. Code 128 Emulation When this parameter is enabled, the scanner transmits data from certain Micro PDF-417 symbols as if it was encoded in Code 128 symbols. If Code 128 Emulation is enabled, the following Micro PDF-417 symbols are transmitted with one of the following prefixes: ]C1 - if the first codeword is 903-907, 912, 914, 915 ]C2 - if the first codeword is 908 or 909
C-34
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 329
Appendix C: Bar Code Settings Codablock
]C0 - if the first codeword is 910 or 911 If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted with one of the following prefixes: ]L3 - if the first codeword is 903-907, 912, 914, 915 ]L4 - if the first codeword is 908 or 909 ]L5 - if the first codeword is 910 or 911 Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.23
Codablock Enable Codablock A Set this parameter to on to enable “Codablock type A”. Enable Codablock F Set this parameter to on to enable “Codablock type F”. Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual