Page 313
Appendix C: Bar Code Settings Decoded (ISCP)
If Code 128 Emulation is set to off, the Micro PDF-417 symbols are transmitted with one of the following prefixes: ]L3 - if the first codeword is 903-907, 912, 914, 915 ]L4 - if the first codeword is 908 or 909 ]L5 - if the first codeword is 910 or 911 Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3
Decoded (ISCP)
•
C.3.1
Tap on the Scanner drop-down menu, and choose Decoded (Intermec ISCP).
Options – Decoded Scanner Laser On Time The value assigned to this parameter determines how long the laser will remain on when the scan button or trigger is pressed. Double-tapping on this parameter displays a dialog box in which you can enter a value between 1 and 10 seconds.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
C-19
Page 314
Appendix C: Bar Code Settings Advanced Options – Decoded Scanner
C.3.2
Advanced Options – Decoded Scanner Continuous Scan Mode Setting this parameter to ‘on’ keeps the laser on and continuously decoding as long as the scanner button is pressed and held down. Minimum Cancel Time The value assigned to this parameter determines the time delay before the scanner is turned off, once the scanner trigger or button is released. This gives the scanner a minimum amount of time to complete its current decode before the scan is cancelled when the user quickly triggers on/off. Low Power Timeout To extend laser life, you can select the length of time the scanner remains active following a successful decode. The scanner wakes from low power mode when a bar code is scanned – a successful decode restores normal blinking. When you double-tap on this parameter, a dialog box is displayed in which you can choose a value of 30 sec, 1 min, 2 min or 3 min. Note: This parameter is only used if the Trigger Mode has been set to Continuous On and NEO is mounted in a fixed position; otherwise, ‘Low Power Timeout’ is not used. Parameter Scanning Setting this parameter to ‘Enabled’ allows decoding of parameter bar codes. Same Read Validate The data is only transmitted after repeated reads give the same result. The value assigned at this parameter determines the number of reads required, from 0 to 10 times. Same Read Timeout Prevents the same bar code from being read more than once. The value assigned determines after what time period the scanner will timeout, from 0 to 2550 msec. Diff Read Timeout Prevents unwanted reading of other bar codes on the same label. The value assigned determines after what time period the scanner will timeout, from 0 to 2550 msec.
C-20
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 315
Appendix C: Bar Code Settings Code 39
Add AIM ID Prefix The AIM ID (Association for Automatic Identification and Mobility) is an international bar code identifier. When this parameter is enabled, the AIM ID is inserted at the beginning of the decoded bar code. Aim Duration This parameter determines the total time the aiming pattern appears before the scanner laser begins sweeping. When you double-tap on this parameter, a dialog box is displayed in which you can enter a value from 0 to 2550 milliseconds. A value of 0 (zero) disables the aiming dot.
C.3.3
Code 39 Enable Setting this parameter to on enables “Code 39”. Full ASCII If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character. Reading Range Determines the reading distance from which a bar code can be successfully scanned. The default setting, Extended, allows for increased reading distance. Start/Stop Transmit Setting this parameter to on enables the transmission of start and stop characters, which are usually not transmitted. Code 39 can start and end with either a * or a $ character (see also next parameter, “Accepted Start Char”). Accepted Start Char This parameter allows the user the option of using one of the two start/stop characters or both ($ char, * char, $ and * char). Check Digit Verification Uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. The available options are: Disabled, MOD 43 Check, French CIP, or Italian CIP. NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
C-21
Page 316
Appendix C: Bar Code Settings Code 128
Note: French CIP (French pharmaceutical) is only used with bar codes containing 7 characters. Italian CIP (Italian pharmaceutical) is also known as Code 32. It is transmitted as a standard Code 39 if checksum is not validated. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.4
Code 128 Enable Setting this parameter to on enables “Code 128”. GS1-128 “GS1-128” is the GS1 implementation of the Code 128 barcode specification. The former correct name was UCC/EAN-128. GS1-128 Identifier “GS1-128 Identifier” allows the AIM ID " ]C1" for EAN 128 to be transmitted or removed. By default, this identifier is transmitted if EAN 128 is enabled. GTIN Compliant GTIN (global trade item number) processing transmits EAN 128 as the 14-character EAN/UCC GTIN. To use GTIN processing, you must activate the EAN 128 symbology. Important: When EAN 128 and GTIN processing are both activated, it is not possible to read normal EAN 128 Codes.
C-22
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 317
Appendix C: Bar Code Settings Code 128
FNC1 Conversion “FNC1 Conversion” allows the embedded FNC1 character to be converted to another character for applications that cannot use the default <GS> Group Separator or hex (1d). Double-tapping on this option displays a dialog box listing the allowable range – 0 to 255. Enable ISBT 128 To successfully scan this type of bar code (International Society of Blood Transfusion), this option must be set to on. If you enable this type of bar code, Code 128/EAN 128 is deactivated to avoid any confusion. ISBT Concat Transmit The codes are not concatenated by default. You need to choose one of the options provided for this parameter to send concatenated code. Choosing Only Concatenated Codes transmits only concatenated codes - single codes will not be transmitted. Choosing Concatenated or Single transmits single codes or concatenated codes. If only one code of a pair is read, that code will be transmitted as a single code. If both codes in a pair are detected, they will be concatenated provided that ISBT Concat Any Pair (see below) is enabled. ISBT Concat Any Pair Enabling this parameter causes all code pairs that can be, to be concatenated even if they do not comply with Section 4.1 of the “ISBT 128 Bar Code Symbology and Application Specification for Labeling of Whole Blood and Blood Components” (June 2000, Version 1.2.1). Reading Range Determines the reading distance from which a bar code can be successfully scanned. The default setting Extended, allows for increased reading distance. Check Digit Verification The available options for this parameter are Disabled or French CIP. This parameter uses the specified algorithm of the option you've chosen to ensure the integrity of the symbol data before transmitting. If the data does not contain that algorithm, the data is not transmitted. Note: French CIP (French pharmaceutical) is only used with bar codes containing 7 characters. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
C-23
Page 318
Appendix C: Bar Code Settings EAN 13
Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.5
EAN 13 Enabled Set this parameter to on to enable “EAN 13”. ISBN Conversion When this parameter (International Standard Book Number) is enabled, the first 3 characters (‘978’) are ignored and the checksum (0.9, ‘X’) is calculated on the remaining characters. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.6
EAN 8 Enabled Set this parameter to on to enable “EAN 8”. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Convert To EAN 13 If this parameter is enabled, an EAN 8 bar code is converted to EAN 13. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C-24
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 319
Appendix C: Bar Code Settings UPCA
C.3.7
UPCA Enabled Set this parameter to on to enable “UPC A” bar code scanning recognition. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Transmit Number System If this parameter is enabled, the number system digit is transmitted with the decoded bar code data. Convert to EAN 13 If this parameter is enabled, a UPC A bar code is converted to EAN 13. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.8
UPC E Enabled Set this parameter to on to enable “UPC E”. Enable UPC-E1 Set this parameter to on to allow “UPC-E1” (zero suppressed) bar code scans. Transmit Check Digit If the check digit is to be transmitted with the data, this parameter must be enabled. Transmit Number System If this parameter is enabled, the number system digit is transmitted with the decoded bar code data. Convert to UPC-A This parameter converts UPC E (zero suppressed) decoded data to UPC A format before transmission. After conversion, data follows UPC A format and is affected by UPC A programming selections (e.g. Check Digit).
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
C-25
Page 320
Appendix C: Bar Code Settings UPC/EAN Shared
Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.9
UPC/EAN Shared The setting assigned to the “Addendum” parameter associated with this option is shared across all UPC and EAN bar codes. Addendum An addendum is a separate bar code, supplementary to the main bar code. This parameter provides two options: Not Required but Transmitted if Read or Required and Transmitted. • Double-tap on Addendum to display a dialog box listing your options. • Highlight an item, and tap on OK. When “Addendum” is set to Not Required but Transmitted if Read, the scanner searches for an addendum and if one exists, appends it to the main bar code. When the parameter is set to Required and Transmitted, the scanner does not accept the main bar code without an addendum. Addendum Add-on 2 and Addendum Add-on 5 Enabling these parameters sets the length of the addendum bar code to either 2 or 5 characters. Addendum Security If you tap on “Addendum Security”, a dialog box is displayed in which you can define the security level of add-on 2 or add-on 5 with a value from 0 to 100. As security levels increase, the scanner decode speed decreases. GTIN Compliant GTIN (global trade item number) processing transmits EAN 128 as the 14-character EAN/UCC GTIN. To use GTIN processing, you must activate the EAN 128 symbology. Important: When EAN 128 and GTIN processing are both activated, it is not possible to read normal EAN 128 Codes. Reading Range This parameter determines the reading distance from which a bar code can be successfully scanned. The default setting, Extended, allows for increased reading distance.
C-26
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 321
Appendix C: Bar Code Settings Code 93
C.3.10
Code 93 Enabled Set this parameter to ‘on’ to enable “Code 93”. Minimum Length Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Length Restriction Refer to “Length Restriction” on page C-8 for details. Add/Remove Data Refer to “Add/Remove Data” on page C-9 for details.
C.3.11
Codabar Enabled Set this parameter to on to enable “Codabar”. Start/Stop Transmit Codabar can use the following sets of characters as start and stop characters: a, b, c, d A, B, C, D a, b, c, d, /, t, n, *, e DC1, DC2, DC3, DC4 Thus, when a set is chosen, the first and last digits of a Codabar message must be one of those characters and the body of the message should not contain these characters. Setting this parameter to Not Transmitted strips the start and stop characters from this bar code. CLSI Library System When enabled, spaces are inserted after characters 1, 5, 10 in the 14-character label (used in the USA by libraries using the CLSI system).
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual