The text of a manual · part 34 of 39
NEO Hand-Held Computer With Windows Mobile 6.1 Classic (Model No. PX750) User Manual, pages 285 to 294
Pages 285 to 294 of 340
The original document is the PDF (13 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Teklogix NEO PX750
Page 285
Appendix B: Teklogix Imagers Applet UPC/EAN Shared Settings
Supplements Separator Supplements Separator is a space that is added between the UPC-E bar code and the Supplement code/Addenda.
B.5.9
UPC/EAN Shared Settings Extended Coupon Code This parameter specifies whether or not the imager will read only UPC-A/EAN-13 bar codes that have addenda. Note: The 2 or 5 digit addenda must be turned on/off, depending on the desired behavior.
B.5.10 Code 93 Enabled Set this parameter to on to enable “Code 93”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 0 to 80.
B.5.11 Codabar Enabled Set this parameter to on to enable “Codabar”. Start/Stop Strip Codabar can use the following sets of characters as start and stop characters: a, b, c, d A, B, C, D a, b, c, d, /, t, n, *, e DC1, DC2, DC3, DC4 Setting this parameter to on strips the start and stop characters from this bar code.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
B-29
Page 286
Appendix B: Teklogix Imagers Applet MSI Plessey
Check Char When this parameter is enabled, before data is output, the “Codabar” symbol integrity is verified based on a parity character that must be present in the code. If the parity character is not part of the code, the code is not output. Keep in mind the parity character may not be part of your output setup; in this case, this parameter should be turned off. Check Char Strip If you enable this parameter, a check character is stripped from the decoded bar code data. Concatenation “Codabar” supports symbol concatenation. When Concatenation is set to on, Codabar uses a ‘D’ stop character to indicate that data from that symbol should be concatenated with data from the adjacent symbol with a ‘D’ start character. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 2 to 60.
B.5.12 MSI Plessey Enabled Set this parameter to on to enable MSI. Enable Plessey Set this parameter to on to enable Plessey. Check Char When this parameter is set to on, the integrity of a “MSI Plessey” symbol is checked to ensure that it complies with specified algorithms. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 4 to 48. Plessey Minimum and Plessey Maximum Length These parameters apply to Plessey bar codes.The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on B-30
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 287
Appendix B: Teklogix Imagers Applet Code 11 these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 4 to 48.
B.5.13 Code 11 Enabled Set this parameter to on to enable “Code 11”. Check Digits Double-tapping on this parameter displays a dialog box in which you can choose One Check Digit or Two check digits. If this parameter is set to One Check Digit, it is assumed that the last digit is a check digit. If it is set to Two Check Digits, it is assumed that the last two digits are check digits. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 80.
B.5.14 Interleaved 2 of 5 Enabled Set this parameter to on to enable “Interleaved 2 of 5”. Check Char When this parameter is set to on, the integrity of a “Interleaved 2 of 5” symbol is checked to ensure that it complies with specified algorithms. Check Char Strip If you enable this parameter, a check character is stripped from the decoded bar code data. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 2 to 80.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
B-31
Page 288
Appendix B: Teklogix Imagers Applet Matrix 2 of 5
B.5.15 Matrix 2 of 5 Enabled Set this parameter to on to enable “Matrix 2 of 5”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 80.
B.5.16 IATA 2 of 5 Enabled Set this parameter to on to enable “IATA 2 of 5”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 48.
B.5.17 Discrete 2 of 5 Enabled Set this parameter to on to enable “Discrete 2 of 5”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 48.
B.5.18 Telepen Enabled Set this parameter to on to enable “Telepen”. Enable AIM Output If you set Enable AIM Output to on, the imager reads symbols with start/stop pattern 1 and decodes them as standard full ASCII (start/stop pattern 1). If you set this parameter to off,
B-32
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 289
Appendix B: Teklogix Imagers Applet GS1 DataBar the imager reads symbols with start/stop pattern 1 and decodes them as compressed numeric with optional full ASCII (start/stop pattern 2). Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 60.
B.5.19 GS1 DataBar GS1 DataBar Set this parameter to on to enable the imager to read “GS1 Databar” symbols. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 4 to 74.
B.5.20 Posi Code (Reduced Space Symbology) Enable Setting this parameter to on enables “Posi Code” scanning capability. Enable Limited A and Enable Limited B “Posi Code” is a “position” based symbology. A position based symbology de-couples the widths of the bars from their positions. The centers of the bars are specified to be laid out on a grid of equally spaced parallel lines. The distance between these grid lines is called the Gdimension and is analogous to the X-dimension of conventional bar codes. There are two variations of this code: Posi Code A, and Posi Code B. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 2 to 80.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
B-33
Page 290
Appendix B: Teklogix Imagers Applet Composite
B.5.21 Composite Enabled Set this parameter to on to enable “Composite” bar codes. Important: To successfully read this type of bar code, the two types of symbologies included in a composite bar code must be enabled.
B.5.22 TLC-39 This composite component integrates MicroPDF417 with the linear code. Enabled Setting this parameter to on enables this parameter.
B.5.23 2D PDF-417 Enabled Set this parameter to on to enable “2D PDF-417”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 2750.
B.5.24 2D Micro PDF-417 Enabled Set this parameter to on to enable “2D Micro PDF-417”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 366.
B.5.25 Code 16K The “Code 16K” bar code is a multiple-row bar code that can encode the full ASCII character set below ASCII 128. It uses existing UPC and Code 128 character set patterns. Up to 77
B-34
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 291
Appendix B: Teklogix Imagers Applet Code 49 full ASCII characters or 154 numeric characters can be encoded into 2 to 16 rows. Each row is divided by a separator bar. The top and bottom of the symbol also have separator bars that extend to the ends of the minimum quiet zones. Enabled Set this parameter to on to enable “Code 16K”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 160.
B.5.26 Code 49 The “Code 49” bar code is a multiple-row bar code that can encode the full ASCII character set below ASCII 128. Up to 49 alphanumeric characters or 81 numeric characters can be encoded into two to eight rows. Each row is divided by a separator bar. The top and bottom of the symbol also have separator bars that extend to the ends of the minimum quiet zones. Enabled Set this parameter to on to enable “Code 49”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 81.
B.5.27 Codablock Enable Set this parameter to on to enable “Codablock”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 2048.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
B-35
Page 292
Appendix B: Teklogix Imagers Applet 2D Data Matrix
B.5.28 2D Data Matrix Enable Set this parameter to on to enable “2D Data Matrix”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 1500.
B.5.29 2D QR Code Enabled Set this parameter to on to enable “2D QR Code”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 3500.
B.5.30 2D Maxicode Enabled Set this parameter to on to enable “2D Maxicode”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 150.
B.5.31 2D Aztec Enabled Set this parameter to on to enable “2D Aztec”. Aztec Runes Aztec Runes, the smallest type of Aztec Code symbol, has the ability to encode a very short license plate message.
B-36
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 293
Appendix B: Teklogix Imagers Applet Postal: PlaNET
Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 1 to 3750.
B.5.32 Postal: PlaNET Enabled Set this parameter to on to enable “Postal: PlaNET”. Check Digit Strip If you enable this parameter, a check digit is stripped from the decoded bar code data.
B.5.33 Postal: PostNET Enabled Set this parameter to on to enable “Postal: PostNET”. Check Digit Strip If you enable this parameter, a check digit is stripped from the decoded bar code data.
B.5.34 Postal: Australian Enabled Set this parameter to on to enable “Postal: Australian”.
B.5.35 Postal: Canadian Enabled Set this parameter to on to enable “Postal: Canadian”.
B.5.36 Postal: China Enabled Set this parameter to on to enable “Postal: China”.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
B-37
Page 294
Appendix B: Teklogix Imagers Applet Postal: Japanese
B.5.37 Postal: Japanese Enabled Set this parameter to on to enable “Postal: Japanese”.
B.5.38 Postal: Kix Enabled Set this parameter to on to enable “Postal: Kix”.
B.5.39 Postal: Korean Enabled Set this parameter to on to enable “Postal: Korean”.
B.5.40 Postal: Royal Enabled Set this parameter to on to enable “Postal: Royal”.
B.5.41 VeriCode® Enabled VeriCode® is a 2D omni-directional symbol. To read this symbol, set this parameter to on.
B-38
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual