The text of a manual · part 33 of 39
NEO Hand-Held Computer With Windows Mobile 6.1 Classic (Model No. PX750) User Manual, pages 275 to 284
Pages 275 to 284 of 340
The original document is the PDF (13 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Teklogix NEO PX750
Page 275
Appendix B: Teklogix Imagers Applet Filter Tab – Manipulating Bar Code Data
B.4.14.1 Modifying a Bar Code Setting The rules for manipulating data from selected bar code symbologies can be modified. To change the settings for a symbology: • • •
Tap on the + symbols to expand the lists and view the parameter settings. Scroll through the parameter list until you reach the parameter that you want to change. For a parameter that can take a range of values: - Highlight the parameter, and then press the [SPACE] key or double-click the parameter. - An associated dialog box containing the valid range of values for the parameter and the current setting like the sample screen following is displayed.
- Type a value in the field provided. •
For a parameter that takes a single character:
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
B-19
Page 276
Appendix B: Teklogix Imagers Applet Translation Tab – Configuring Rules
- Highlight the parameter and then press the [SPACE] key, or double-click on the parameter. The following screen is displayed:
•
When you’ve completed your edits, tap on OK.
B.4.15 Translation Tab – Configuring Rules Translation rules enable the automatic processing of bar code data. Up to 10 cases can be defined, each consisting of up to 10 sequential rules. Note: Changes made to the translations configuration using the Teklogix Scanners applet are synchronized with changes made here. Changes made in either place affect both translation tables. • Tap on Start>Settings>System tab.
B-20
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 277
Appendix B: Teklogix Imagers Applet Advanced Tab
•
Tap on the Teklogix Imagers icon, and then tap on the Translation tab.
For instructions on adding, editing, and removing translation rules, refer to the “Translations Tab” on page 159.
B.4.16 Advanced Tab B.4.16.1 File Locations for Captured Images To configure the location for saved images, open the dialog box as follows: • •
Tap on Start>Settings>System tab. Tap on the Teklogix Imagers icon, and then tap on the Advanced tab.
To define the location where imager files will be stored:
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
B-21
Page 278
Appendix B: Teklogix Imagers Applet Advanced Tab
•
Tap on the File Location button.
• • •
Type the file Name, choose the Folder and file Type. Choose the Location in which your files will be saved. When you have completed all the changes, tap on the Save button.
B.4.16.2 Configuring Triggers Viewing the Trigger Configuration The trigger on NEO is configured using the Manage Triggers applet. The Teklogix Imagers applet provides a shortcut to the Manage Triggers applet. •
B-22
In the Advanced tab, tap on the Trigger Control button.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 279
Appendix B: Teklogix Imagers Applet Bar Code Symbologies – Descriptions
•
To view all the triggers and the hardware devices that are configured to use them, tap in the checkbox next to Show all modules.
Adding, Editing and Removing Triggers For instruction about adding, editing and removing triggers, refer to “Manage Triggers” on page 141.
B.5
Bar Code Symbologies – Descriptions To view all symbologies available for the imager: •
Tap on the Barcoding tab, and tap on All.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
B-23
Page 280
Appendix B: Teklogix Imagers Applet Options
Note: Remember that if you want to edit the symbologies, the preset you want to change must be active. Highlight the preset you want to edit, and tap on the Activate button – an A is added at the far right of the preset. With the activated preset highlighted, double-tap on the Edit button.
B.5.1
Options Auto Retry On Failed Decode Enabled Setting this parameter to on allows the imager to repeat the image capture attempt if the initial attempt fails. The number of retries is dependent on the value assigned in the next parameter, Max Number of Auto Retry. If this parameter is set to off, the imager will only attempt the image capture once. Max Number of Auto Retry The value assigned for this parameter governs the number of times the imager will attempt to capture a bar code if the first attempt fails to a maximum of 99 times. Decoder Timeout This parameter determines the maximum time that the decoder will spend searching for a bar code on a captured image. The value assigned here is dependent on the type of bar code and quality of the image being captured. For example, the value may need to be increased to compensate for larger bar codes with more data encoded or for poor quality images. On the other hand, the value can be decreased for smaller, good quality images. The allowable value ranges from 200 to 500 msec. Single Target Mode Enabled When this parameter is enabled, the decoder assumes that a single bar code exists in the image and that it is located in the centre of the image. Add AIM ID Prefix The AIM ID (Association for Automatic Identification and Mobility) is an international bar code identifier. When this parameter is enabled, the AIM ID is inserted at the beginning of the decoded bar code.
B.5.2
Code 39 Enabled Setting this parameter to on makes “Code 39” readable to the imager.
B-24
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 281
Appendix B: Teklogix Imagers Applet Trioptic Code
Full ASCII If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character. Start/Stop Strip “Code 39” has start/stop patterns that can be output as ASCII characters in the output data. When Start/Stop Strip is enabled, start/stop characters are not output. Check Char When this parameter is enabled, before data is output, the “Code 39” symbol integrity is verified based on a parity character that must be present in the code. If the parity character is not part of the code, the code is not output. Keep in mind the parity character may not be part of your output setup; in this case, this parameter should be turned off. Check Char Strip If this parameter is set to on, check characters – if present – are not output. Concatenation When Concatenation is set to on, all decoded “Code 39” symbols with a SPACE as the first data character are concatenated to the internal buffer. Data from the last “Code 39” symbol without a SPACE is added to the buffer as well, and the entire buffer will be output. Pharmaceutical This is a numeric (0-9) fixed length barcode used by Italian pharmacies. It is also referred to as Code 32 Pharmacode and is a form of Code 39. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays screens in which you can set the minimum and maximum allowable code lengths – 0 to 48.
B.5.3
Trioptic Code Note: “Trioptic Code” and “Full ASCII” should not be enabled simultaneously. The scanner does not automatically discriminate between these two symbologies.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
B-25
Page 282
Appendix B: Teklogix Imagers Applet Code 128
Enable Trioptic Code symbols always contain six characters. Setting this parameter to on allows this type of symbology to be recognized.
B.5.4
Code 128 Enabled Set this parameter to on to enable “Code 128”. ISBT Concatenation These codes are not concatenated by default. You need to set this parameter to on to send concatenated code. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays screens in which you can set the minimum and maximum allowable code lengths – 0 to 80.
B.5.5
EAN 13 Enabled Set this parameter to on to enable “EAN 13”. Check Digit Strip If you enable this parameter, a check digit is stripped from the decoded bar code data. Supplements 2 and Supplements 5 Supplements are additions to EAN/UPC codes. These addendums can be 2 or 5 characters in length. Usually, data from an addendum is a suffix to the main symbol output data. Mandatory Enabled When this parameter is set to on, the imager does not accept the main bar code without a supplement. Supplements Separator A Supplements Separator is a space that is added between the EAN 13 bar code and the Supplement code/Addenda.
B-26
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
Page 283
Appendix B: Teklogix Imagers Applet EAN 8
ISBN Translate When this parameter (International Standard Book Number) is enabled, the first 3 characters (‘978’) are ignored and the checksum (0.9, ‘X’) is calculated on the remaining characters.
B.5.6
EAN 8 Enabled Set this parameter to on to enable “EAN 8”. Check Digit Strip If you enable this parameter, a check digit is stripped from the decoded bar code data. Supplements 2 and Supplements 5 Supplements are additions to EAN/UPC codes. These addendums can be 2 or 5 characters in length. Usually, data from an addendum is a suffix to the main symbol output data. Mandatory Enabled When this parameter is set to on, the imager does not accept the main bar code without a supplement. Supplements Separator Supplements Separator is a space that is added between the EAN 8 bar code and the Supplement code/Addenda.
B.5.7
UPC-A Enabled Set this parameter to on to enable “UPC-A”. Check Digit Strip If you enable this parameter, a check digit, if present, is stripped from the decoded bar code data. Number System If this parameter is enabled, the number system digit is transmitted with the decoded bar code data.
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual
B-27
Page 284
Appendix B: Teklogix Imagers Applet UPC-E Settings
Supplements 2 and Supplements 5 Supplements are additions to EAN/UPC codes. These addendums can be 2 or 5 characters in length. Usually, data from an addendum is a suffix to the main symbol output data. Mandatory Enabled When this parameter is set to on, the imager does not accept the main bar code without a supplement. Supplements Separator Supplements Separator is a space that is added between the UPC-A bar code and the Supplement code/Addenda.
B.5.8
UPC-E Settings Enabled Set this parameter to on to enable “UPC E”. Enabled UPC-E1 Set this parameter to on to allow “UPC-E1” (zero suppressed) bar code scans. Expand This parameter expands the UPC-E code to a 12 digit UPC-A format. Check Digit Strip If you enable this parameter, a check digit is stripped from the decoded bar code data. Number System If this parameter is enabled, the number system digit is transmitted with the decoded bar code data. Supplements 2 and Supplements 5 Supplements are additions to EAN/UPC codes. These addendums can be 2 or 5 characters in length. Usually, data from an addendum is a suffix to the main symbol output data. Mandatory Enabled When this parameter is set to on, the imager does not accept the main bar code without a supplement.
B-28
NEO Hand-Held with Windows Mobile 6.1 Classic User Manual