Page 251

Appendix D: Teklogix Imagers Applet Advanced Tab

To define the location where imager files will be stored: •

Tap on the File Location button.

• • •

Type the file Name, choose the Folder and file Type. Choose the Location in which your files will be saved. When you have completed all the changes, tap on the Save button.

Psion Teklogix NEO Hand-Held Computer User Manual

D-19

Page 252

Appendix D: Teklogix Imagers Applet Bar Code Symbologies – Descriptions

D.4.16.2 Configuring Triggers Viewing the Trigger Configuration The trigger on NEO is configured using the Manage Triggers applet. The Teklogix Imagers applet provides a shortcut to the Manage Triggers applet. • •

In the Advanced tab, tap on the Trigger Control button. To view all the triggers and the hardware devices that are configured to use them, tap in the checkbox next to Show all modules.

Adding, Editing and Removing Triggers For instruction about adding, editing and removing triggers, refer to “Manage Triggers” on page 98.

D.5

Bar Code Symbologies – Descriptions To view all symbologies available for the imager: •

Tap on the Barcoding tab, and tap on All. Note: Remember that if you want to edit the symbologies, the preset you want to change must be active. Highlight the preset you want to edit, and tap on the Activate button – an A is added at the far right of the preset. With the activated preset highlighted, double-tap on the Edit button.

D-20

Psion Teklogix NEO Hand-Held Computer User Manual

Page 253

Appendix D: Teklogix Imagers Applet Options

D.5.1

Options Auto Retry On Failed Decode Enabled Setting this parameter to on allows the imager to repeat the image capture attempt if the initial attempt fails. The number of retries is dependent on the value assigned in the next parameter, Max Number of Auto Retry. If this parameter is set to off, the imager will only attempt the image capture once. Max Number of Auto Retry The value assigned for this parameter governs the number of times the imager will attempt to capture a bar code if the first attempt fails to a maximum of 99 times. Decoder Timeout This parameter determines the maximum time that the decoder will spend searching for a bar code on a captured image. The value assigned here is dependent on the type of bar code and quality of the image being captured. For example, the value may need to be increased to compensate for larger bar codes with more data encoded or for poor quality images. On the other hand, the value can be decreased for smaller, good quality images. The allowable value ranges from 200 to 500 msec. Single Target Mode Enabled When this parameter is enabled, the decoder assumes that a single bar code exists in the image and that it is located in the centre of the image. Add AIM ID Prefix The AIM ID (Association for Automatic Identification and Mobility) is an international bar code identifier. When this parameter is enabled, the AIM ID is inserted at the beginning of the decoded bar code.

D.5.2

Code 39 Enabled Setting this parameter to on makes “Code 39” readable to the imager. Full ASCII If this parameter is enabled, the characters +, %, and / are used as escape characters. The combination of an escape character and the next character is converted to an equivalent ASCII character.

Psion Teklogix NEO Hand-Held Computer User Manual

D-21

Page 254

Appendix D: Teklogix Imagers Applet Trioptic Code

Start/Stop Strip “Code 39” has start/stop patterns that can be output as ASCII characters in the output data. When Start/Stop Strip is enabled, start/stop characters are not output. Check Char When this parameter is enabled, before data is output, the “Code 39” symbol integrity is verified based on a parity character that must be present in the code. If the parity character is not part of the code, the code is not output. Keep in mind the parity character may not be part of your output setup; in this case, this parameter should be turned off. Check Char Strip If this parameter is set to on, check characters – if present – are not output. Concatenation When Concatenation is set to on, all decoded “Code 39” symbols with a SPACE as the first data character are concatenated to the internal buffer. Data from the last “Code 39” symbol without a SPACE is added to the buffer as well, and the entire buffer will be output. Pharmaceutical This is a numeric (0-9) fixed length barcode used by Italian pharmacies. It is also referred to as Code 32 Pharmacode and is a form of Code 39. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays screens in which you can set the minimum and maximum allowable code lengths – 0 to 48.

D.5.3

Trioptic Code Note: “Trioptic Code” and “Full ASCII” should not be enabled simultaneously. The scanner does not automatically discriminate between these two symbologies. Enable Trioptic Code symbols always contain six characters. Setting this parameter to on allows this type of symbology to be recognized.

D-22

Psion Teklogix NEO Hand-Held Computer User Manual

Page 255

Appendix D: Teklogix Imagers Applet Code 128

D.5.4

Code 128 Enabled Set this parameter to on to enable “Code 128”. ISBT Concatenation These codes are not concatenated by default. You need to set this parameter to on to send concatenated code. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays screens in which you can set the minimum and maximum allowable code lengths – 0 to 80.

D.5.5

EAN 13 Enabled Set this parameter to on to enable “EAN 13”. Check Digit Strip If you enable this parameter, a check digit is stripped from the decoded bar code data. Supplements 2 and Supplements 5 Supplements are additions to EAN/UPC codes. These addendums can be 2 or 5 characters in length. Usually, data from an addendum is a suffix to the main symbol output data. Mandatory Enabled When this parameter is set to on, the imager does not accept the main bar code without a supplement. Supplements Separator A Supplements Separator is a space that is added between the EAN 13 bar code and the Supplement code/Addenda. ISBN Translate When this parameter (International Standard Book Number) is enabled, the first 3 characters (‘978’) are ignored and the checksum (0.9, ‘X’) is calculated on the remaining characters.

Psion Teklogix NEO Hand-Held Computer User Manual

D-23

Page 256

Appendix D: Teklogix Imagers Applet EAN 8

D.5.6

EAN 8 Enabled Set this parameter to on to enable “EAN 8”. Check Digit Strip If you enable this parameter, a check digit is stripped from the decoded bar code data. Supplements 2 and Supplements 5 Supplements are additions to EAN/UPC codes. These addendums can be 2 or 5 characters in length. Usually, data from an addendum is a suffix to the main symbol output data. Mandatory Enabled When this parameter is set to on, the imager does not accept the main bar code without a supplement. Supplements Separator Supplements Separator is a space that is added between the EAN 8 bar code and the Supplement code/Addenda.

D.5.7

UPC-A Enabled Set this parameter to on to enable “UPC-A”. Check Digit Strip If you enable this parameter, a check digit, if present, is stripped from the decoded bar code data. Number System If this parameter is enabled, the number system digit is transmitted with the decoded bar code data. Supplements 2 and Supplements 5 Supplements are additions to EAN/UPC codes. These addendums can be 2 or 5 characters in length. Usually, data from an addendum is a suffix to the main symbol output data.

D-24

Psion Teklogix NEO Hand-Held Computer User Manual

Page 257

Appendix D: Teklogix Imagers Applet UPC-E Settings

Mandatory Enabled When this parameter is set to on, the imager does not accept the main bar code without a supplement. Supplements Separator Supplements Separator is a space that is added between the UPC-A bar code and the Supplement code/Addenda.

D.5.8

UPC-E Settings Enabled Set this parameter to on to enable “UPC E”. Enabled UPC-E1 Set this parameter to on to allow “UPC-E1” (zero suppressed) bar code scans. Expand This parameter expands the UPC-E code to a 12 digit UPC-A format. Check Digit Strip If you enable this parameter, a check digit is stripped from the decoded bar code data. Number System If this parameter is enabled, the number system digit is transmitted with the decoded bar code data. Supplements 2 and Supplements 5 Supplements are additions to EAN/UPC codes. These addendums can be 2 or 5 characters in length. Usually, data from an addendum is a suffix to the main symbol output data. Mandatory Enabled When this parameter is set to on, the imager does not accept the main bar code without a supplement. Supplements Separator Supplements Separator is a space that is added between the UPC-E bar code and the Supplement code/Addenda.

Psion Teklogix NEO Hand-Held Computer User Manual

D-25

Page 258

Appendix D: Teklogix Imagers Applet UPC/EAN Shared Settings

D.5.9

UPC/EAN Shared Settings Extended Coupon Code This parameter specifies whether or not the imager will read only UPC-A/EAN-13 bar codes that have addenda. Note: The 2 or 5 digit addenda must be turned on/off, depending on the desired behavior.

D.5.10 Code 93 Enabled Set this parameter to on to enable “Code 93”. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 0 to 80.

D.5.11 Codabar Enabled Set this parameter to on to enable “Codabar”. Start/Stop Strip Codabar can use the following sets of characters as start and stop characters: a, b, c, d A, B, C, D a, b, c, d, /, t, n, *, e DC1, DC2, DC3, DC4 Setting this parameter to on strips the start and stop characters from this bar code. Check Char When this parameter is enabled, before data is output, the “Codabar” symbol integrity is verified based on a parity character that must be present in the code. If the parity character is not part of the code, the code is not output. Keep in mind the parity character may not be part of your output setup; in this case, this parameter should be turned off.

D-26

Psion Teklogix NEO Hand-Held Computer User Manual

Page 259

Appendix D: Teklogix Imagers Applet MSI Plessey

Check Char Strip If you enable this parameter, a check character is stripped from the decoded bar code data. Concatenation “Codabar” supports symbol concatenation. When Concatenation is set to on, Codabar uses a ‘D’ stop character to indicate that data from that symbol should be concatenated with data from the adjacent symbol with a ‘D’ start character. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 2 to 60.

D.5.12 MSI Plessey Enabled Set this parameter to on to enable MSI. Enable Plessey Set this parameter to on to enable Plessey. Check Char When this parameter is set to on, the integrity of a “MSI Plessey” symbol is checked to ensure that it complies with specified algorithms. Minimum and Maximum Length The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 4 to 48. Plessey Minimum and Plessey Maximum Length These parameters apply to Plessey bar codes.The length of a code refers to the number of characters (i.e., human readable characters), including check digit(s). Double-tapping on these parameters displays a screen in which you can set the minimum and maximum allowable code lengths – 4 to 48.

Psion Teklogix NEO Hand-Held Computer User Manual