Page 233
APPENDIX D TEKLOGIX IMAGERS APPLET The Teklogix Imagers applet is used to create, modify, delete, and activate imager settings. The principal uses of the application are to decode bar codes and to capture images. A Demonstration Application is provided to demonstrate how the imager works. Refer to “Imager Demo Applet” on page 134 for details.
D.1
Required Applets In order to configure imaging, the Manage Triggers applet must be present in the Control Panel, along with the Teklogix Imagers applet.
D.2
Presets There are two methods that can be used to configure an imager using the Teklogix Imagers applet: • •
Use a predefined preset. Create a custom preset based on a predefined preset. Important: It is strongly recommended that a predefined preset is used whenever possible. Each predefined preset contains a coherent group of settings that are known to work together in the intended environment. In almost all situations, at least one of the predefined presets results in a satisfactory outcome.
A preset is a group of exposure and image correction settings. Each preset configures the imager for a specific purpose such as bar code decoding or image capture. Presets also allow easier and faster configuration of the imager after power-on or resume from suspend. The predefined presets are generic and satisfy most user requirements. A custom preset can be created for a specific user application, such as: include only specified bar codes, read only a specified number of bar codes or for reading unusual media. Every preset belongs to a preset type. The following preset types are available: Psion Teklogix NEO Hand-Held Computer User Manual
D-1
Page 234
Appendix D: Teklogix Imagers Applet Predefined Presets
• Imaging for photo capture. • Imaging for bar code decoding. • Symbology selection. At any time, only one preset of each type can be designated as the user-selected active preset.
D.2.1
Predefined Presets Predefined presets are built into the imaging software and cannot be changed. The predefined presets allow you to use the imager to perform specified tasks without having to understand and set numerous variables. In almost all cases these predefined presets are sufficient.
D.2.2
Bar Code Predefined Presets These presets encompass the majority of the most popular bar codes and their subtypes. The bar code decoding symbology predefined presets define which bar codes can be decoded. The bar code decoding camera predefined presets determine how the bar code images are captured.
D.2.2.1
Bar Code Decoding Symbology Predefined Presets The following presets select groups of similar bar codes for decoding. Note: It is recommended that the default preset be used whenever possible. Factory Default This preset enables the decoding of frequently used bar codes. My Default This preset uses the Symbology Settings menu to define the preset. For details about the Symbology Settings menu, refer to “Bar Coding Tab – Configuring Symbologies” on page D-15. All This preset enables the decoding of all bar codes that the imager can decode. Linear This preset enables the decoding of all the 1D symbologies that the imager can decode.
D-2
Psion Teklogix NEO Hand-Held Computer User Manual
Page 235
Appendix D: Teklogix Imagers Applet Bar Code Decoding Camera Predefined Presets
Linear and PDF417 This preset enables the decoding of all the 1D and PDF symbologies that the imager can decode. Matrix This preset enables the decoding of all 2D symbologies that the imager can decode. Postal This preset enables the decoding of all the postal symbologies that the imager can decode.
D.2.3
Bar Code Decoding Camera Predefined Presets The following presets enable successful bar code image capture in almost all conditions. Note: It is recommended that the default preset be used whenever possible. Default This preset works in a wide range of conditions. It is optimized for a normal office lighting (about 300 Lux). Low light This preset is designed for very dark conditions such as inside a warehouse where the lights are kept low, or inside an unlit truck. This preset increases either the exposure time or the gain. Low power This preset minimizes the use of the flash so as to conserve the battery power on the handheld. Glossy surface This preset minimizes the use of the flash so as to reduce reflection. This preset is used to read bar codes that are behind glass, or inside the plastic window of an envelope.
D.2.4
Image Capture Predefined Presets The following presets enable successful image capture in almost all conditions. Note: It is recommended that the default preset be used whenever possible.
Psion Teklogix NEO Hand-Held Computer User Manual
D-3
Page 236
Appendix D: Teklogix Imagers Applet Using the Teklogix Imagers Applet
Default This preset works in a wide range of conditions. It is optimized for a normal office lighting (about 300 Lux). Motion This preset uses a shorter exposure time so as to freeze motion. Low light near This preset is designed for dark conditions, it uses a longer exposure time and includes the flash.
D.3
Using the Teklogix Imagers Applet
D.3.1
Configuring the Image Capture Presets To configure the image capture presets, open the dialog box as follows: • •
Tap on Start>Settings>Control Panel. Tap on the Teklogix Imagers icon, and if it’s not already selected, tap on the Imaging tab.
Figure D.1 Imaging Tab
D-4
Psion Teklogix NEO Hand-Held Computer User Manual
Page 237
Appendix D: Teklogix Imagers Applet Selecting a Camera
This window lists all the presets, both predefined and custom. Presets are identified as follows: • • •
D.3.2
Predefined presets are marked as ‘R’ read-only. Custom presets are marked as ‘RW’ read and write. One preset – either predefined or custom – is marked as ‘A’ active.
Selecting a Camera To select a camera: • •
D.3.3
Tap on the Camera Presets drop-down menu to view the camera options. Choose a camera – specifically, Front Imager which is located at the top of the unit.
Setting the Active Preset An active preset has an A to the right. To set an active preset: •
D.3.4
Highlight the preset, and tap on the Activate button.
Viewing a Preset To view the parameter settings in a preset: • Highlight a preset, and tap on the View button. The associated preset window is displayed.
•
Tap on the + sign to expand the lists so that you can view the parameter settings.
Psion Teklogix NEO Hand-Held Computer User Manual
D-5
Page 238
Appendix D: Teklogix Imagers Applet Creating a Custom Preset
D.3.5
Creating a Custom Preset A new custom preset is created by modifying a preset – either a predefined preset or an existing custom preset. To create a custom preset: • Highlight a preset, and tap on the Add button. A screen like the sample below is displayed.
• Type the name of the new preset in the dialog box. • Tap on OK to save your changes. The preset list is displayed; the new custom preset appears at the end of the list. It is marked as read and write (RW).
D.3.6
Modifying a Custom Preset The parameter values in a custom preset can be modified. It is recommended that very few changes be made to a custom preset. To ensure that it will work reliably, it should be as close as possible to the original predefined preset. To change a parameter value: •
D-6
Highlight the custom preset, and tap on the Edit button.
Psion Teklogix NEO Hand-Held Computer User Manual
Page 239
Appendix D: Teklogix Imagers Applet Modifying a Custom Preset
• • •
Tap on the + symbols to expand the lists so that you can view the parameter settings. Scroll through the parameter list until you reach the parameter that you want to change. For a parameter that can take a range of values: - Highlight the parameter, and then press the [SPACE] key or double-click on the parameter. - An associated dialog box containing the valid range of values for the parameter and the current setting like the sample screen following is displayed.
- Type a value in the field provided. •
For a parameter that toggles between two values such as on or off and enabled or disabled: - Highlight the parameter and then press the [SPACE] key, or double-click on the parameter. Either method toggles between the two available values.
•
When you’ve completed your edits, tap on OK.
Psion Teklogix NEO Hand-Held Computer User Manual
D-7
Page 240
Appendix D: Teklogix Imagers Applet Removing a Custom Preset
The parameter list is displayed; the new value for the changed parameter is shown. •
D.3.7
Tap on OK to exit to the preset list and save the changes.
Removing a Custom Preset • Highlight the custom preset you want to delete, and tap on the Remove button. A window is displayed warning you that you are about to remove a preset. •
D.4
Tap on Yes to remove the preset or No to cancel the operation.
Configuring the Bar Code Decoding Camera Presets To configure the bar code decoding camera presets: • •
Tap on Start>Settings>Control Panel>Teklogix Imagers. Tap on the Barcoding tab.
Figure D.2 Bar Code Presets
This window lists all the presets, both predefined and the custom. Presets are identified as follows: • • D-8
Predefined presets are marked as read-only. For a description, review “Predefined Presets” on page D-2. Predefined presets are marked as ‘R’ read-only.
Psion Teklogix NEO Hand-Held Computer User Manual
Page 241
Appendix D: Teklogix Imagers Applet Selecting a Camera
• •
Custom presets are marked as RW – read and write. One preset – either predefined or custom – is marked as ‘A’ active. Note: The top portion of the window displays the bar code decoding camera presets.
The top port of the window displays the bar code decoding camera presets.
D.4.1
Selecting a Camera To select a camera: • •
D.4.2
Tap on the Camera Presets drop-down menu to view the camera options. Choose a camera – specifically, Front Imager which is located at the top of the unit.
Setting the Active Preset An active preset has an A to the right; in Figure D.3 on page 12, the active preset is Default. To set an active preset: •
D.4.3
Highlight the preset, and tap on the Activate button.
Viewing a Preset To view the parameter settings in a preset: • Highlight a preset, and tap on the View button. The associated preset window is displayed.
Psion Teklogix NEO Hand-Held Computer User Manual
D-9