Page 171
Chapter 6: Peripheral Devices & Accessories Docking Station Charger LED Indicators
6.5.5
Docking Station Charger LED Indicators The desktop docking station is equipped with a single tri-coloured LED indicator in the lower-right corner of the front panel that indicates various charge states of the spare battery installed in the docking station. Note: During the first two minutes of a battery charge, the LED remains solid yellow while the hand-held computer status is assessed and the super capacitor is charged.
Table 6.3 Desktop Docking Station Charger LED Behaviour LED Behaviour
Charge Status
Off
No battery detected in the slot.
Solid Yellow
Battery charged to less than 75% of capacity.
Flashing Green
Battery charged to between 75% and 95% of capacity.
Solid Green
Charge complete.
Flashing Yellow
Battery is not charging. The battery temperature is outside of the charge range of 0º C to 45º C.
Solid Red
Battery is not charging. Battery fault.
Note: Battery charging continues whether the hand-held is switched on or off.
6.5.6
Troubleshooting the Charging Operation of The Dock
6.5.6.1 Indicator Solid Red If the indicator is solid red: • Remove the battery and disconnect the mains power cable. • Wait at least 20 seconds, and then plug the cable in again. If the charge well LED remains solid red, the battery may be defective or there is a power supply problem. 6.5.6.2 NEO Power LED Does Not Light Up • • •
Ensure NEO is fully seated in the dock. Verify that there is power from the mains outlet. Remove the power cable from the docking station, and check it for damage. Psion Teklogix NEO Hand-Held Computer User Manual
159
Page 172
Chapter 6: Peripheral Devices & Accessories Linking NEO to a PC
•
Reconnect the power cable to the outlet.
6.5.6.3 Indicator Does Not Light When Battery Installed • • • • •
6.5.7
Reinstall the battery, and check that it is fully seated in the charge well. Remove the battery, and clean the contacts on the battery and the charge well. Inspect the charge well contacts for damage (are they bent, flattened, twisted or broken). Try inserting a battery that you know to be working in the charge well. Reconnect the power cable, and check that the charge well indicator flashes at powerup.
Linking NEO to a PC The desktop docking station can be connected to a PC so that you can exchange files or install applications. A USB cable is included with your docking station. Note: For information about data transfer with the Windows XP operating system and ActiveSync or with the Vista operating system, refer to “Data Transfer Between The PC And The Hand-Held” on page 19. To link NEO to a PC: • •
6.5.8
Insert the hand-held in the desktop docking station. Insert the micro-USB connector into the docking station connector. Attach the other end of the cable into a USB port on the PC.
Linking NEO to an Ethernet Network A micro-USB Ethernet adaptor cable – model number PX3052 – is used to connect NEO to an Ethernet network through a desktop docking station. • •
Insert the micro-USB connector on the adaptor cable into the micro-USB port on the back of the desktop docking station. Connect your network Ethernet cable to the Ethernet port on the adaptor cable.
6.5.8.1 Network Access The hand-held unit automatically detects insertion into the desktop dock and loads the appropriate drivers to communicate with the micro-USB Ethernet converters. Network Addressing The host application uses standard TCP/IP protocol to name, locate and communicate with a specific NEO on the network.
160
Psion Teklogix NEO Hand-Held Computer User Manual
Page 173
Chapter 6: Peripheral Devices & Accessories Troubleshooting USB Operations
If a link is established between NEO and a host, the application on the host and on the handheld must have a recovery mechanism in the event that NEO is removed from the dock, interrupting the link.
6.5.9
Troubleshooting USB Operations • • •
6.6
Ensure that the unit is fully seated in the dock. A dock icon should be visible in the task bar. Ensure the USB cabling is connected properly. Ensure NEO and docking station contacts are not contaminated.
AC Wall Adaptor– Model No. PX3012 The AC wall adaptor available for your docking station allows you to operate your handheld using AC power while charging the battery inserted in the unit. Adaptor plugs suitable for use in various countries are shipped with the AC wall adaptor. DC Power Plug
Universal AC Power Supply
Adaptor Plugs
•
• •
6.7
Choose the adaptor plug that is suitable for use in your country. Slide the adaptor plug into the Universal AC power supply, snapping it into place. These two pieces, coupled together, are referred to as an AC wall adaptor. Insert the DC power plug into the DC IN socket at the back of the charger. Plug the pronged end into an AC outlet.
Cigarette Lighter Adaptor, Model PX3056 The cigarette lighter adaptor allows you to power your hand-held and recharge your battery using power drawn from your vehicle’s automotive power outlet when used in conjunction with the DC/USB Adaptor, Model No. PX3054. Psion Teklogix NEO Hand-Held Computer User Manual
161
Page 174
Chapter 6: Peripheral Devices & Accessories Quad Docking Station – PX3004 PC & PX3004 NPC
Figure 6.11 Automotive Power Adaptor
Automotive Power Adaptor Plug DC Power Plug
•
• •
Attach the micro-USB adaptor, model number PX3054, to the base of NEO. Refer to “Micro-USB Adaptor – Model No. PX3054” on page 154 if you require further details. The desktop docking station is also equipped with a DC IN socket to which you can connect the automotive adaptor. Insert the DC power plug on the automotive adaptor into the DC IN socket on the Micro-USB adaptor or desktop docking station. Insert the automotive power adaptor plug into automotive power outlet in your vehicle. Note: Battery charging continues whether the hand-held is switched on or off.
6.8
Quad Docking Station – PX3004 PC & PX3004 NPC
Note: The quad docking station is shipped with a user manual. It is critical that this manual be reviewed for additional information and updates.
162
Psion Teklogix NEO Hand-Held Computer User Manual
Page 175
Chapter 6: Peripheral Devices & Accessories Quad Docking Station Setup
The quad docking station permits each of four docked NEOs to communicate with a 10/100 BaseT Ethernet network. It also provides sufficient power to operate the hand-helds and charge their batteries. Important: The Ethernet connection on the quad docking station is designed for indoor use only!
6.8.1
Quad Docking Station Setup Refer to instruction sheet PN 1081342 for a checklist of startup steps. You can find this instruction sheet on Teknet. Go to www.psionteklogix.com. Tap on Teknet and enter you user name and password. If you’re not already a member, you will be asked to register free of charge.
6.8.2
Quad Docking Station Indicators The quad dock is equipped with a power indicator LED and RJ45 link and traffic indicator LEDs. When a valid link is established, a green LED is illuminated next to the RJ45 connector.
6.8.3
Inserting NEO in the Quad Docking Station • Slide NEO into the cradle portion of the quad dock until lightly latched. The LED on the hand-held unit lights up to show it has external power and may start charging the battery. Interaction with NEO while in the quad dock is a function of the user application software used to communicate with the host network.
6.8.4
Network Access The quad docking station has one 10/100 Ethernet port. You can insert up to four hand-held units. The hand-helds are connected to an internal USB hub. The hand-held unit automatically detects insertion into a quad docking station and loads the appropriate drivers to communicate with the USB/Ethernet converters.
6.8.4.1 Network Addressing Although the USB converters have fixed Ethernet MAC addresses, there is generally no correlation between these addresses and a specific hand-held. The host application uses standard TCP/IP protocol to name, locate and communicate with a specific NEO on the network. Psion Teklogix NEO Hand-Held Computer User Manual
163
Page 176
Chapter 6: Peripheral Devices & Accessories Battery Charging – LED Behaviour
If a link is established between NEO and a host, the application on the host and on the handheld must have a recovery mechanism in the event that NEO is removed from the dock and the link is interrupted.
6.8.5
Battery Charging – LED Behaviour Charge status is displayed on the hand-held LED. Refer to Table 6.3 on page 159 for detailed LED charge behaviour. When inserted in the quad dock, NEO requires 3 hours to charge to charge the battery to 75% capacity. Charge durations are independent of the number of NEOs docked. Note: The specified battery charge times are based on NEO being powered off. Additional peripherals and other power consumption features will also alter the specified charge time.
6.8.6
Troubleshooting The indicators, applications and drivers required to use and monitor the docking station are installed on NEO – no indicators or applications are present on the docking station itself.
6.8.6.1 Network Link Unsuccessful If a network link fails, the application must take appropriate action. 6.8.6.2 NEO LED Does Not Light When Docked • • • • • • •
6.9
Check that the quad docking station has power: Is the Power LED on the docking station illuminated? Try inserting NEO in another well in the quad dock. Check for dirt or contamination on the docking contacts at the bottom of NEO. Wipe the contacts with a damp cloth if necessary. Check the connector pins inside the dock cradle for dirt. Gently wipe with a soft cloth if they appear to be dirty or discoloured. Check that the contacts are not bent or damaged. Remove and reinsert NEO in the cradle. Make certain that the battery installed in NEO is not defective.
Scanners and Imagers NEO supports 1D laser scanner (SE955), 2D imager (HHP 5000) and 1D imager (EV15) options to address a variety of user application requirements. The scanner installed in your
164
Psion Teklogix NEO Hand-Held Computer User Manual
Page 177
Chapter 6: Peripheral Devices & Accessories Basic Scanner Operations unit can be configured using the Scanner Settings dialog box in the Control Panel (see “Teklogix Scanner Settings” on page 135 and Appendix C, “Bar Code Settings,”) and the Manage Triggers application (see page 98). If a 2D imager is installed in your unit, the imager can be configured using the Teklogix Imager applet. For details, refer to “Imager Demo Applet” on page 134 and Appendix D: “Teklogix Imagers Applet”. Important: It is critical that you review the “NEO Hand-Held Computer Regulatory & Warranty Guide, PN 8000175, before proceeding.
6.9.1
Basic Scanner Operations • •
6.9.2
Turn the hand-held on. Wait until the unit has booted up completely. Aim at the bar code and press the scan key or the trigger. A scan beam and a warning indicator appear until a successful decode is achieved or six seconds have elapsed.
Scanning Techniques •
NEO’s unique ergonomic design allows you to hold the hand-held at a comfortable angle while scanning. • Ensure that the scanner beam is not perpendicular to the bar code. Light reflected directly back into the scanner’s exit window may prevent a successful decode. • Scan the entire bar code. If you are using a 1D laser scanner, make certain that the scan beam crosses every bar and space on the bar code, including the margins on either end of the symbol. • When using imaging scanners, do not move the scanner while decoding the bar code. Movement blurs the image. • Hold the scanner farther away for larger bar codes. • Hold the scanner closer for bar codes with bars that are close together. A bar code icon appears on the screen during a scan. While the scanner beam is active, the onscreen message states: SCANNING. If you want to turn off the onscreen message, disable Scan Indication in the Options tab of the Scanner Settings menu in the Control Panel. When the scan is successful, the bar code data is displayed on the screen until the scan button (or pistol trigger) is released, but only if Scan Result is turned on in the Options tab of the Scanner Settings menu in the Control Panel.
Psion Teklogix NEO Hand-Held Computer User Manual
165
Page 178
Chapter 6: Peripheral Devices & Accessories Troubleshooting
6.9.3
Troubleshooting If the scanner is not working, investigate the following: • • • • • •
6.10
Check that the bar code symbology being scanned is enabled for the hand-held you are using. Check any other parameters that affect the scanning procedure or the bar code. Check the bar code to make sure it is not damaged. Try scanning a different bar code to verify that the problem is not with the bar code. Check that the bar code is within the specified decode zone. Refer to “Scanner/Imager Specifications” on page 173 for details. Does the hand-held display the warning without scanning? This suggests a hardware problem in the hand-held. Is the laser beam scanning across the bar code? Once the scan beam has stopped, check the scanner window for dirt, fogging or damage.
Bluetooth Peripherals NEOs equipped with Bluetooth radios make it possible to communicate with a variety of Bluetooth peripherals, including GSM/GPRS handsets, scanners, printers, and so on. The range of the Bluetooth radio is limited to approximately 10 meters. Psion Teklogix provides built-in support for the Bluetooth peripherals listed below. • GSM/GPRS universal handset. • Bluetooth printer. • Bluetooth headset. Keep in mind that Bluetooth and IEEE 802.11b/g radios both operate in the 2.4GHz band. Although NEO includes features to minimize interference, performance of the system will not be optimal if you use both radios simultaneously. Typically, when both radios operate in the hand-held at the same time, they cannot transmit simultaneously – this has a negative impact on overall system throughput. To minimize the impact on the backbone 802.11g network, Psion Teklogix recommends using Bluetooth peripherals that have low transaction rates (such as printers and scanners). Refer to “Bluetooth Setup” on page 102 for information about setting up your Bluetooth devices for communication. In addition, review the manual shipped with your Bluetooth device to determine the method used to pair with the NEO host.
166
Psion Teklogix NEO Hand-Held Computer User Manual