The text of a manual · part 5 of 44
7535 G2 Hand-Held Computer User Manual: Approvals And Safety Summary
Pages 23 to 30 of 372, from 7535 G2 Hand-Held Computer User Manual
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Teklogix 7535 G2
Page 23
APPROVALS AND SAFETY SUMMARY FCC DECLARATION OF CONFORMITY (DOC) Applicant’s Name & Address:
PSION TEKLOGIX INC. 2100 Meadowvale Blvd. Mississauga, Ontario Canada L5N 7J9 Tel: (905) 813-9900
US Representative’s Name & Address:
PSION TEKLOGIX CORP. 1810 Airport Exchange Blvd., Suite 500 Erlanger, KY, 41018, USA Tel: (859) 372-4329
Equipment Type/Environment:
Computing Devices
Trade Name / Model No.:
7535 G2 Hand-Held Computer with Portable Docking Module
Year of Manufacture:
2006
Standard(s) to which Conformity is Declared: The 7535 G2 Hand-Held Computer with Portable Docking Module, supplied by Psion Teklogix, has been tested and found to comply with FCC PART 15, SUBPART B - UNINTENTIONAL RADIATORS, CLASS B COMPUTING DEVICES FOR HOME & OFFICE USE. I, the undersigned, hereby declare that the equipment as tested is representative within manufacturing tolerance to units.
Applicant
Legal Representative in U.S.
Signature
Signature
Mike Doyle
Kyle Day
Full Name
Full Name
Vice President, Engineering
Vice President, Channel Sales
Position
Position
Mississauga, Ontario, Canada
Hebron, KY 41048, USA
Place
Place
June 2006
June 2006
Date
Date Psion Teklogix 7535 G2 Hand-Held Computer User Manual xix
Page 24
Chapter : Approvals And Safety Summary
CE Marking When used in a residential, commercial or light industrial environment the product and its approved UK and European peripherals fulfil all requirements for CE marking. R&TTE Directive 1999/5/EC This equipment complies with the essential requirements of EU Directive 1999/5/EC (Declaration available: www.psionteklogix.com). Cet équipement est conforme aux principales caractéristiques définies dans la Directive européenne RTTE 1999/5/CE. (Déclaration disponible sur le site: www.psionteklogix.com). Die Geräte erfüllen die grundlegenden Anforderungen der RTTE-Richtlinie (1999/5/EG). (Den Wortlaut der Richtlinie finden Sie unter: www.psionteklogix.com). Questa apparecchiatura è conforme ai requisiti essenziali della Direttiva Europea R&TTE 1999/5/CE. (Dichiarazione disponibile sul sito: www.psionteklogix.com). Este equipo cumple los requisitos principales de la Directiva 1995/5/CE de la UE, “Equipos de Terminales de Radio y Telecomu-nicaciones”. (Declaración disponible en: www.psionteklogix.com). Este equipamento cumpre os requisitos essenciais da Directiva 1999/5/CE do Parlamento Europeu e do Conselho (Directiva RTT). (Declaração disponível no endereço: www.psionteklogix.com). Ο εξοπλισμός αυτός πληροί τις βασικές απαιτήσεις της κοινοτικής οδηγίας EU R&TTE 1999/5/EΚ. (Η δήλωση συμμόρφωσης διατίθεται στη διεύθυνση: www.psionteklogix.com) Deze apparatuur voldoet aan de noodzakelijke vereisten van EU-richtlijn betreffende radioapparatuur en telecommunicatie-eindappa-ratuur 199/5/EG. (verklaring beschikbaar: www.psionteklogix.com). Dette udstyr opfylder de Væsentlige krav i EU's direktiv 1999/5/EC om Radio- og teleterminaludstyr. (Erklæring findes på: www.psionteklogix.com). Dette utstyret er i overensstemmelse med hovedkravene i R&TTE-direktivet (1999/5/EC) fra EU. (Erklæring finnes på: www.psionteklogix.com). Utrustningen uppfyller kraven för EU-direktivet 1999/5/EC om ansluten teleutrustning och ömsesidigt erkännande av utrustningens överensstämmelse (R&TTE). (Förklaringen finns att läsa på: www.psionteklogix.com). Tämä laite vastaa EU:n radio- ja telepäätelaitedirektiivin (EU R&TTE Directive 1999/5/EC) vaatimuksia. (Julkilausuma nähtävillä osoitteessa: www.psionteklogix.com). xx
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 25
Chapter : Approvals And Safety Summary
Psion Teklogix tímto prohlašuje, že 7535 G2 je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1995/5/ES (NV č. 426/2000 Sb.) a Prohlášení o shodě je k dispozici na www.psionteklogix.com. Toto zarízení lze provozovat v České republice na základě generální licence č. GL-12/R/2000. Psion Teklogix týmto vyhlasuje, že 7535 G2 spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1995/5/ES (NV č. 443/2001 Z.z.) a Vyhlásenie o zhode je k dispozícii na www.psionteklogix.com. Toto zariadenie je možné prevádzkovat’ v Slovenskej republike na základe Všeobecného povolenia č. VPR-01/2001. Use of the 802.11g 7535 G2 Hand-Held in France:
Owing to French Government restrictions, the 802.11g 7535 G2 Hand-Held Computer is limited to indoor use. It may be used outdoors, on private property, only with prior authorization from the French Ministry of Defense. FCC Information To Users Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • • •
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. Psion Teklogix 7535 G2 Hand-Held Computer User Manual xxi
Page 26
Chapter : Approvals And Safety Summary
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. Important: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment under 47 CFR 2.1093 paragraph (d)(2), for use in a PDA. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Some equipment in hospitals and aircraft are not shielded from radio frequency energy. Do not use the 7535 G2 hand-held onboard aircraft, or in hospitals, without first obtaining permission. Do not use near pacemakers. The product may affect the operation of some medically implanted devices such as pacemakers, causing them to malfunction. Avoid placing your product next to such devices. Keep a minimum distance of 20 cm between the device and the product to reduce the risk of interference. If you have any reason to suspect that interference is taking place, turn off the 7535 G2 hand-held and contact your cardiologist for assistance. Note: To maintain compliance with the FCC RF exposure guidelines, if you wear the 7535 G2 on your body, use the Psion Teklogix approved carrying case. Use of non-approved accessories may violate FCC RF exposure guidelines. Emissions Information For Canada This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations. When using the 802.11 radio option, to prevent radio interference, this device is intended to be operated indoors and away from windows to provide maximum shielding. Equipment (or its transmit antenna) that is installed outdoors is subject to licensing. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. En cas d’utilisation du module radio 802.11, afin d'éviter toute interférence radio avec le service autorisé, l'appareil doit être utilisé à l'intérieur, tout en tant éloigné de toute fenêtre afin de garantir le maximum de protection. Si cet équipement (ou son antenne émettrice) est installé à l'extérieur, il est alors soumis à licence.
xxii
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 27
Chapter : Approvals And Safety Summary
Warnings To Users This product is a Class I/Class II laser product according to CDRH 21 CFR 1040.10 and 1040.11 and Class1/Class 2 laser product according to IEC 60825-1 Ed. 2.0. The SE1200 ALR has an maximum radiated power less than 1.4 mW; according to EN 60825-1: 2001 it is classified as a Class 3B laser product. Laser Warnings
Important: For your own safety, it is critical that you comply with the following warnings. •
Do not look into the laser beam or point the beam at people or animals Aperture A label is affixed below the aperture.
• • • •
Using controls or adjustments, or performing procedures other than those specified herein may result in hazardous radiation exposure. The use of optical instruments (magnification devices) with this product will increase eye hazard. DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE. Operating Psion Teklogix equipment where explosive gas is present may result in an explosion. DO NOT REMOVE COVERS OR OPEN ENCLOSURES. To avoid injury, the equipment covers and enclosures should only be removed by qualified service personnel. Do not operate the equipment without the covers and enclosures properly installed.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual xxi-
Page 28
Chapter : Approvals And Safety Summary
•
•
Danger of explosion if a 7535 G2 battery is incorrectly handled, charged, disposed of or replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the instructions described in “Lithium-ion Battery Safety Precautions”, below. Carefully review all battery safety issues. VORSICHT! Explosiongefahr bei unsachgemäßem Austausch der Batterie Ersatz nur durch denselben oder einen vom Hersteller empfohlenen gleichwertigen Typ. Entsorgung gebrauchter Batterien nach Angaben des Herstellers.
Lithium-ion Battery Safety Precautions
Important: Before charging or using the battery pack, it is critical that the safety information in this section is reviewed and that all warnings are strictly followed.
Warning: BATTERIES ARE CONSIDERED HAZARDOUS WASTE and must be returned to Psion Teklogix for proper disposal. Forward all used batteries to one of the following offices: Psion Teklogix Inc. 2100 Meadowvale Blvd. Mississauga, Ontario Canada L5N 7J9
Psion Teklogix Corp. 3000 Kustom Drive Hebron, Kentucky USA 41048
Psion Teklogix S.A. La Duranne, 135 Rue Rene Descartes BP 421000, 13591 Aix-En-Provence Cedex 3; France Warning: TO PREVENT the battery from leaking acid, generating heat or exploding, adhere to the precautions listed below. • •
• • • xxiv
The battery incorporates built-in safety devices. To ensure their proper function, do not disassemble or alter any parts of the battery. Do not short-circuit the battery by directly connecting any of the exposed terminals with metal objects such as wire. Do not transport or store the battery together with metal objects such as necklaces, hair pins, etc. Do not dispose of batteries in fire. Do not use or leave the battery near a heat source such as a fire or heater. Do not immerse the battery in water.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 29
Chapter : Approvals And Safety Summary
• • • • • •
When charging, use the battery charger specifically designed for the battery. Do not pierce, strike, throw or step on the battery. Do not directly solder the battery. Do not connect the battery to an electrical outlet, vehicle cigarette lighter, etc. Do not put battery into a microwave oven or pressurized container. Do not use the battery in combination with primary batteries (such as dry-cell batteries) or batteries of different capacities or brands. • Immediately remove the battery from the device or battery charger and stop use if the battery gives off an odour, generates heat, becomes discoloured or deformed, or in any way appears abnormal during use. • Do not continue charging the battery if it does not recharge within the specified charge time. • The battery may burst or ignite if the battery leaks. Always ensure that it is away from any exposed flames. • If leaking electrolyte sprays into your eyes, rinse them with clean running water, and immediately seek medical attention. • Do not store the battery in extremely high temperatures (e.g., a vehicle, strong direct sunlight, etc.). This may cause the battery to overheat or ignite, and it may also reduce the performance and service life of the battery. • Do not use in areas where static electricity is greater than what the manufacturer guarantees. • Keep batteries out of reach of children. Always switch the unit off before changing the battery. While the battery is being replaced, the 7535 G2 will save its current data for at least 10 minutes. Important: Charger And AC/DC Adaptor Safety Instructions • •
•
SAVE THESE INSTRUCTIONS – This manual contains important safety and operating instructions for battery chargers and AC/DC adaptors. Before using the battery charger or AC/DC adaptor, read all instructions and cautionary markings on the (1) AC/DC adaptor, (2) battery charger, (3) battery, and (4) product using the battery. The mains power cord shall comply with national safety regulations of the country where the equipment is to be sold.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual xxv
Page 30
Chapter : Approvals And Safety Summary
• • • • •
• • •
Use of an attachment not recommended or sold by the battery charger or AC/DC adaptor manufacturer may result in fire, electric shock, or personal injury. To reduce risk of damage to the electric plug and cord when unplugging the charger or AC/DC adaptor, pull the plug rather than the cord. Make sure the cord is positioned so that it is not stepped on, tripped over, or otherwise subjected to damage or stress. Do not operate the charger or AC/DC adaptor with a damaged cord or plug. Replace immediately. Do not operate the charger or AC/DC adaptor if it has received a sharp blow, been dropped, or otherwise damaged in any way; it should be inspected by qualified service personnel. Do not disassemble the charger or AC/DC adaptor; it should be repaired by qualified service personnel. Incorrect reassembly may result in electric shock or fire. To reduce risk of electric shock, unplug the charger or AC/DC adaptor from the outlet before attempting any maintenance or cleaning. An extension cord should not be used unless absolutely necessary. Use of an improper extension cord could result in fire or electric shock. If an extension cord must be used, make sure: - The plug pins on the extension cord are the same number, size, and shape as those on the charger or AC/DC adaptor. - The extension cord is properly wired and in good electrical condition and that the wire size is larger than 16 AWG.
• •
• xxvi
Do not expose the charger or AC/DC adaptor to rain or snow. Do not use the charger if, after an overnight charge, any of the batteries feel warmer than the charger housing. The charger should be inspected by qualified service personnel. Do not use the charger if any of the batteries or the charger get more than lukewarm. Do not use the AC/DC adaptor if it gets more than lukewarm. The equipment should be inspected by qualified personnel.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual