The text of a manual · part 25 of 44
7535 G2 Hand-Held Computer User Manual: Peripheral Devices & Accessories 6, pages 207 to 214
Pages 207 to 214 of 372, from 7535 G2 Hand-Held Computer User Manual
The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Teklogix 7535 G2
Page 207
PERIPHERAL DEVICES & ACCESSORIES
6
6.1 External Bar Code Readers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .179 6.1.1 PowerScan® Standard, LR and XLR Bar Code Scanners . . . . . . . . . .179 6.1.2 Entering Data With The Bar Code Reader . . . . . . . . . . . . . . . . . .179 6.2 RD7950 Integrated UHF RFID Reader . . . . . . . . . . . . . . . . . . . . . . . .179 6.3 Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180 6.4 Battery Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180 6.4.1 Battery Gas Gauge Calibration. . . . . . . . . . . . . . . . . . . . . . . .180 6.5 Gang Charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181 6.5.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .181 6.5.2 Operator Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182 6.5.3 Charge Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .182 6.5.4 Charging Batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183 6.5.5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183 6.5.5.1 Excessive Charge Duration . . . . . . . . . . . . . . . . . . . . .183 6.5.5.2 Improper Battery Storage . . . . . . . . . . . . . . . . . . . . . .183 6.5.5.3 Indicator Flashing Red . . . . . . . . . . . . . . . . . . . . . . .184 6.5.5.4 Power LED Does Not Light Up. . . . . . . . . . . . . . . . . . .184 6.5.5.5 Indicator Does Not Light When Battery Installed . . . . . . . . .184 6.6 Combo Charger. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184 6.6.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .184 6.6.2 Operator Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185 6.6.3 Using the Combo Charger With The 7535 G2 . . . . . . . . . . . . . . . .185 6.6.4 Charging The Spare Battery . . . . . . . . . . . . . . . . . . . . . . . . .185 6.6.5 Charge Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186 6.6.6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186 6.7 Combo Dock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186 6.7.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .186 6.7.2 Using The Combo Dock . . . . . . . . . . . . . . . . . . . . . . . . . . .186 6.7.3 Network Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187 6.7.4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .187 Psion Teklogix 7535 G2 Hand-Held Computer User Manual
177
Page 208
6.8 Quad Dock. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 6.8.1 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 6.8.2 Indicators And Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 6.8.3 Using The Quad Dock. . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 6.8.4 Network Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 6.8.4.1 Network Addressing . . . . . . . . . . . . . . . . . . . . . . . . 189 6.8.5 Battery Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 6.8.6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 6.8.6.1 Network Link Unsuccessful . . . . . . . . . . . . . . . . . . . . 189 6.8.6.2 7535 G2 LED Does Not Light When Docked . . . . . . . . . . . 189 6.9 Portable Docking Module (PDM). . . . . . . . . . . . . . . . . . . . . . . . . . . 190 6.10 Bluetooth Peripherals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 6.11 The 7535 G2 Picker Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 193 6.11.1 Picker Cradle Mounting Recommendations . . . . . . . . . . . . . . . . 193 6.11.1.1 Mounting Template . . . . . . . . . . . . . . . . . . . . . . . . 194 6.11.2 Wiring Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 194 6.11.3 Using The Picker Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . 194 6.11.4 Maintaining The Picker Cradle . . . . . . . . . . . . . . . . . . . . . . 194 6.11.5 Powered Cradle Installation In High Voltage Vehicles . . . . . . . . . . 195 6.11.5.1 Extreme Wet Environments. . . . . . . . . . . . . . . . . . . . 195 6.11.6 Powered Cradle Installation . . . . . . . . . . . . . . . . . . . . . . . . 196 6.11.7 Wiring Vehicle Power To The Cradle . . . . . . . . . . . . . . . . . . . 197 6.11.8 The Port Replicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 6.12 Tether Adaptor Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
178
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 209
Chapter 6: Peripheral Devices & Accessories External Bar Code Readers
6.1
External Bar Code Readers
6.1.1
PowerScan® Standard, LR and XLR Bar Code Scanners Note: Refer to “PowerScan Standard Range Scanner Specifications” on page 219 and “PowerScan® LR and XLR Industrial Scanner Specifications” on page 216 for detailed specifications. The 7535 G2 supports Psion Teklogix’ PowerScan® industrial bar code scanner with standard, long range and extra long range options. To connect this scanner to the 7535 G2, attach the device to the tether port at the upper-right side of the 7535 G2. Before using the bar code reader, you may need to change some parameters (see “Non-Decoded Scanners” on page C-55). Review your Power Scan Programming Guide (PSC) for details.
6.1.2
Entering Data With The Bar Code Reader Note: For helpful scanning tips, refer to “Scanning Techniques” on page 59. For external non-decoding scanners, when a label is scanned successfully, the 7535 G2 will beep if configured appropriately and the scan LED will flash. (Most external decoding scanners have their own indicators - some communicate with the unit.) Occasionally, the bar code labels are poorly printed or damaged and cannot be read properly. In this case, use the keyboard to enter data from the label.
6.2
RD7950 Integrated UHF RFID Reader Note: Refer to the RD7950 UHF RFID Reader Quick Reference Guide (P/N 8000056) for detailed information and specifications. The RD7950 UHF RFID Reader is an EPC-compliant RFID reader available for Psion Teklogix rugged hand-held computing devices. The RD7950 can be retrofitted to deployed Psion Teklogix products. Multimedia data capture capabilities are delivered by combining RFID with existing technologies such as laser bar code scanning or imaging.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
179
Page 210
Chapter 6: Peripheral Devices & Accessories Batteries
6.3
Batteries Note: Battery specifications are detailed beginning on page 221. 7535 G2s operate with lithium-ion batteries - a high capacity 1900 mAh battery pack. For detailed safety instructions, please see “Lithium-ion Battery Safety Precautions” on page xxiv. For details on battery charging and installation, see “Powering Up The 7535 G2” on page 14. For battery calibration and power settings, see “Power Management Properties” on page 118.
6.4
Battery Charging Note: Initially, new batteries that have been fully charged may indicate slightly less than 100% charge. No special conditioning is required. The full capacity of the battery will reach 100% after 5 charge cycles through the charger. It can take from 1.5 to 4 hours to charge a battery. The 7535 G2’s intelligent charging system protects the battery from over-charging by terminating the charge process when the battery is at maximum capacity. See “Approvals And Safety Summary” on page xix, for important safety and operating instructions for battery chargers and AC/DC adaptors. Important: To preserve battery integrity, the charger will proceed with a charge only when the battery temperature falls between 5° C and 39° C (41° F to 102° F). If the battery is too hot or cold, the battery status LED flashes yellow and the charge is suspended.
6.4.1
Battery Gas Gauge Calibration The gas gauge indicator on the hand-held system tray and in the Power Properties dialog has a typical accuracy of +/- 5% of nominal capacity. In order to keep this accuracy the gas gauge (which is stored in the battery pack) needs to be calibrated occasionally. Whenever the battery is fully discharged and then fully charged, the gas gauge becomes recalibrated. For most users the issue of gas gauge recalibration should be invisible. If the battery is only partially discharged or partially charged, at least 40 times, the gas gauge will start to drift out of calibration. When this happens the gas gauge accuracy could decline to +/- 15% of nominal. A calibration cycle (full discharge / full charge) is needed to fully recalibrate the gas gauge. Even if the battery is never recalibrated, the gas gauge accuracy will not drop below +/- 20% of nominal.
180
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 211
Chapter 6: Peripheral Devices & Accessories Gang Charger
A feature is built into the HU3006 gang charger and the HU3002/HU4002 Combo Charger/Dock which detects a battery that requires calibration and will fully discharge it and charge it - but only if the remaining capacity is less than 30% of a full charge. On the HU3006, only one of the six slots can perform a calibration cycle at any one time. This calibration cycle extends the overall charge time by up to 4 hours. A charger that is performing the initial discharge portion of a calibration cycle will flash its LED yellow at fast rate (a slow flashing yellow LED indicates the battery is outside of the charge temperature). The HU3002/HU4002 can also perform a calibration cycle on a battery installed on the handheld, but this function can be disabled in the Power Properties dialog (see “Calibrate” on page 122). It is not necessary to perform an initial calibration cycle on a brand new battery, although the gas gauge may have slightly less than +/- 5% accuracy. It should be noted that as a battery ages its capacity declines, and this is shown on the gas gauge as an inability to charge the battery to 100%. The 100% setting corresponds to the nominal capacity of a new battery (as stated on the battery cover). A battery that cannot be charged beyond 70% of its nominal capacity is considered to be at its end of life.
6.5
Gang Charger The HU3006 is designed to charge up to six 7535 G2 lithium-ion batteries at one time. Your charger is shipped with the appropriate IEC mains power cord. If the supplied power cord is incorrect for your country, contact Psion Teklogix for assistance. Important: The gang charger is shipped with a user manual. It is critical that this manual be reviewed for additional information and updates.
6.5.1
Installation The gang charger can be wall mounted using the wall mount kit (HU3106) or it can be operated on a flat surface. Install the charger in an area that is free from excessive dirt, dust and contaminants. The ambient temperature must be in the range 5° C to 39° C (41° F to 102° F). The charger will not charge batteries outside of this temperature range. For maximum performance, it is recommended that the charger be operated at room temperature - a temperature range between 18° C to 25° C (64° F to 77° F). The charger can consume up to 2A @ 120VAC or 1A @ 240VAC. Check to ensure the mains circuit supplying the charger is adequate for this loading (especially if several chargers are being powered from the same circuit). After unpacking the unit: •
Visually check the charger for damage. Psion Teklogix 7535 G2 Hand-Held Computer User Manual
181
Page 212
Chapter 6: Peripheral Devices & Accessories Operator Controls
• Install the IEC power cord and apply power. A green indicator in the lower-right indicates power is present. All charge indicators flash momentarily at powerup to indicate that the charger is ready for operation. If you choose to wall mount the charger, follow the instructions packaged with the mounting bracket kit. Be sure to locate the charger in an area where there is no risk of injury to persons walking in the vicinity.
6.5.2
Operator Controls The gang charger does not have operator controls or a power switch.
6.5.3
Charge Indicators Each battery charge slot is equipped with a tri-coloured LED to indicate the charge status of the battery. When 7535 G2 batteries are inserted in the charger, the colour and behaviour of the LEDs associated with the charge wells in use indicate the status of the charge. Table 6.1 Gang Charger Indicators
LED Behaviour
182
Icon
Charge Status
Off
No battery detected in the slot.
Solid green
Battery is fully charged.
Flashing green
Battery is charged to 75% capacity.
Solid yellow
Charge in progress.
Flashing yellow
Battery temperature out of charge range between 5° C to 39° C (41° F to 102° F). This icon indicates that the charger is waiting to charge. Charging is attempted every five minutes until the battery is within the appropriate temperature range.
Solid red
Battery rejected (at insertion) or unable to complete charge on battery
Flashing red
Charging circuit problem. Refer to “Troubleshooting” on page 183.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
Page 213
Chapter 6: Peripheral Devices & Accessories Charging Batteries
6.5.4
Charging Batteries •
Install the battery with the battery contacts facing the charger. Slide the battery between the guide rails until it lightly latches in place. The LED directly below the slot in which a battery is inserted lights up immediately. A solid yellow LED indicates that the battery is being charged. If the battery temperature is outside 5° C to 39° C (41° F to 102° F), the LED flashes yellow until the temperature is acceptable. A fully discharged battery will normally take between 1.5 and 4 hours to charge. When the battery charge reaches 75%, the indicator flashes green. At full capacity, it turns solid green. When the battery is fully charged, the charger stops applying power; the battery cannot be overcharged if left in the charger slot. The 75% charge indicator is handy if you need a quick recharge - it often occurs after less than an hour. Storing batteries in the gang charger for extended periods (more than a week or two) is not recommended. Lithium-ion batteries lose capacity if they are maintained at full charge for long periods of time. See the battery storage recommendations in “Storing Batteries” on page 42.
6.5.5
Troubleshooting
6.5.5.1 Excessive Charge Duration The charger is equipped with a recalibration function - a function that fully discharges and then fully recharges the battery. This process is necessary to recalibrate the battery capacity gauge internal to the battery. The charger attempts recalibration when: • • the battery capacity is at less than 30%, and the battery has undergone more than 40 partial charge cycles since the last full discharge. A complete battery discharge takes between 1.5 and 4 hours to complete. When in discharge mode, the LED indicator flashes yellow. The recalibration function extends the charge time by up to 2 hours.
6.5.5.2 Improper Battery Storage Storing batteries in the gang charger for extended periods (more than a week or two) is not recommended. Lithium-ion batteries lose capacity if they are maintained at full charge for long periods of time. See the battery storage recommendations in “Storing Batteries” on page 42.
Psion Teklogix 7535 G2 Hand-Held Computer User Manual
183
Page 214
Chapter 6: Peripheral Devices & Accessories Combo Charger
6.5.5.3 Indicator Flashing Red If the indicator flashes red: • Remove all batteries and disconnect the mains power cable. • Wait at least 20 seconds, and then plug the cable in again. If any of the charge slot LEDs continue to flash red, the charger is defective and requires service. If all indicators are flashing red, there is a power supply problem and the charger requires service. 6.5.5.4 Power LED Does Not Light Up • • • •
Remove all batteries, and unplug the charger. Connect another device to the mains outlet to ensure there is power. Remove the IEC mains power cable from the charger, and check it for damage. Reconnect the mains cable in the charger and mains outlet.
6.5.5.5 Indicator Does Not Light When Battery Installed • • • • •
6.6
Remove the battery, and clean the contacts on the battery and the charge slot. Reinstall the battery, and check that it is fully seated in the slot. Inspect the charge slot contacts for damage (are they bent, flattened, twisted or broken). Try inserting a battery that you know to be working in the charger slot. Reconnect the mains power cable, and check that the slot indicator flashes at powerup.
Combo Charger The 7535 G2 combo charger is a desktop charger designed to charge the 7535 G2 internal battery along with a spare battery pack. The combo charger provides sufficient power to operate and fast charge the 7535 G2 internal battery, while recharging the spare battery pack. Note: The combo charger is shipped with a user manual. It is critical that this manual be reviewed for additional information and updates.
6.6.1
Installation Keep the combo charger away from excessive dirt, dust and contaminants. The combo charger will not charge batteries outside an ambient temperature range of 5° C to 39° C (41° F to 102° F). It is recommended that this charger be operated at room temperature between 18° C and 25° C (64° F to 77° F) for maximum performance. After unpacking the unit:
184
Psion Teklogix 7535 G2 Hand-Held Computer User Manual