Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 20 of 44

7535 G2 Hand-Held Computer User Manual: Configuration 5, pages 165 to 174

Pages 165 to 174 of 372, from 7535 G2 Hand-Held Computer User Manual

The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Teklogix 7535 G2

Page 165

Chapter 5: Configuration Properties

5.7.6

Properties

The Properties menu displays information about your 7535 G2, and provides some port options. The Device Name field shows the device name of your 7535 G2. This name can be changed (see the Note on the previous page for details). Device Class shows the Class of Device (e.g. desktop, hand-held), which is always set to Handheld. Local Bluetooth Address shows the address of your 7535 G2 radio. Port Prefix is used to set the port name to either BSP or COM. When the name is set to BSP, BSP2 to BSP9 are available for activated services (including the server). When COM is chosen, COM7 to COM9 are available. NQuery Retry (Name Query Retry) governs the number of times the hand-held will attempt to query the names of other Bluetooth devices if the first attempt fails. (When the 7535 G2 scans for other devices, it sometimes fails to scan names.) Note: Keep in mind that setting this parameter to a higher value will lengthen the scan time. The option Hide this device from others prevents other devices from connecting to your 7535 G2.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

135

Page 166

Chapter 5: Configuration Search For

5.7.7

Search For

The Search For menu allows you to specify the services for which the Bluetooth radio will scan.

5.8

Error Reporting Error Reporting allows you to enable or disable Microsoft error reporting prompts. •

136

Tap on Start>Settings>Control Panel>Error Reporting icon to access your options.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 167

Chapter 5: Configuration IPv6 Support

5.9

IPv6 Support The IPv6 Support icon in the Control Panel allows you to activate IPv6 network support on your unit if your network setup requires this. This internet protocol specification (version 6) supports 128-bit IP addresses, replacing version 4.

•

Choose the IPv6 Support icon to display the associated dialog box.

•

Choose the checkbox next to Enable IPv6 Network Support to enable this internet protocol.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

137

Page 168

Chapter 5: Configuration Scanner Settings

5.10

Scanner Settings The Teklogix Scanners icon in the Control Panel provides dialog boxes in which you can tailor bar code options and choose the bar codes your scanner will recognize. The parameters are preset with the default settings of the decoded scanner installed in the unit.

For a listing of available scanners and their specifications, please refer to Chapter 7: “Specifications”.

138

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 169

Chapter 5: Configuration Bar Codes

5.10.1 Bar Codes

5.10.1.1 Scanner The drop-down menu to the right of the Scanner option allows you to choose configurations for one of the following scanner types, depending on what is installed in/on your hand-held: Decoded (internal), Decoded (Intermec ISCP), Imager and Non-decoded. The symbologies listed in the Barcodes tab change to reflect the scanner you choose and the bar codes it supports. Always defer to your bar code scanner’s programming manual when in doubt about the availability or settings for any parameter. Note: Your 7535 G2 comes preconfigured from the factory for internal scanner types. The type of scanner installed can be determined from the System icon in the Control Panel, under the System Properties tab. Important: To improve the decode speed and performance, enable (set to ‘on’) only those codes that are required by the application. For information on configuring the bar code symbologies, see Appendix C: “Bar Code Settings”. Keep in mind that some bar code types are only available when an internal imaging scanner is installed. All internal scanners can be configured using these dialog boxes. External, nondecoded scanners are also configured through the Scanner Properties dialog box. However, external decoded scanners must be configured by scanning special configuration bar codes. In these cases, the scanner manufacturer provides programming manuals for configuration purposes. Psion Teklogix 7535 G2 Hand-Held Computer User Manual

139

Page 170

Chapter 5: Configuration Bar Codes Restoring Default Settings

• •

For the Symbol LS3408 decoded scanner, refer to the programming guide supplied with your scanner. For PowerScan® (PSC) decoded scanners, refer to the PowerScan Programming Guide.

5.10.1.2 Restoring Default Settings If you want to restore the factory defaults after making changes, the defaults can be applied to a selected parameter, sub-tree of parameters or all scanner parameters. •

Press and hold the stylus on a symbology (e.g., Code 128) to display a pop up a menu.

•

Choose Default subtree to reset only the parameters in the symbology you selected, or choose Default all settings to reset all scanner parameters to default settings. To reset a single parameter to its default setting:

140

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 171

Chapter 5: Configuration Options

•

Press and hold the stylus on the parameter you want to reset.

•

Choose Default parameter to reset the parameter to the default setting.

5.10.2 Options This tab allows you to tailor the double-click parameters and the display options associated with your scanner.

5.10.2.1 Double Click Parameters Click Time (msec) This parameter controls the maximum gap time (in milliseconds) for a double-click. If the time between the first and second clicks of the scanner trigger is within this time, it is conPsion Teklogix 7535 G2 Hand-Held Computer User Manual

141

Page 172

Chapter 5: Configuration Options sidered a double-click. The allowable range is 0 to 1000. A value of zero disables this feature. A double-click produces different results depending on whether or not a value is assigned in the “Click Data” parameter. When a value is not assigned for the “Click Data”, double-clicking the scanner trigger overrides the target dot delay set in the “Dot Time” parameter and initiates a normal scan sweep. If a value is assigned for the “Click Data” parameter, doubleclicking the scanner trigger inserts the “Click Data” value rather than initiating a scan. Click Data For both integrated and external scanners, this parameter determines which character is sent to the application installed in your 7535 G2 following a double-click. A dialog box appears, asking that you press the key you want to insert. The ASCII/Unicode key value of the keypress is displayed. Pressing the [ESC] key in this dialog box resets the data to zero. 5.10.2.2 Display Parameters Scan Result When this parameter is enabled, the type of bar code and the result of the scan appear on the screen. Note that this information is only displayed after a successful decode and is visible only while the scanner trigger is pressed. When the trigger is released, this information is cleared from the screen. Scan Indicator When this parameter is enabled, the laser warning logo appears on the display whenever the scanner is activated. Scan Result Time (sec) The value assigned to the Scan Result Time parameter determines how long the scan results of a successful scan are displayed on the screen. Time is measured in seconds, and a value of 0 (zero) disables the parameter. When you choose this option, a dialog box appears where you can enter a value. Note: To remove the scan result from the screen before the “Result Time” has expired, point the scanner away from the bar code and press the trigger.

142

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 173

Chapter 5: Configuration Translations

Good Scan Beep And Bad Scan Beep These parameters determine whether or not the 7535 G2 emits an audible scanner ‘beep’ when a good (successful) scan or a bad (unsuccessful) scan is performed. Set these parameters to either on to enable the beeper or off to disable it. Soft Scan Timeout This parameter is used by the SDK “Scan” function (soft-scan: starting a scan session via the SDK function, instead of a physical user trigger press). The value assigned to this parameter determines the soft-scan timeout from 1 to 10 sec (default is 3 sec). Scan Log File If this parameter is enabled, the input bar code and the modified/translated output bar code are logged in the file \Flash Disk\ScanLog.txt. Keep in mind that if Scan Log File is enabled, there is a slight performance reduction when performing multiple scans since the log file is written to persistent storage.

5.10.3 Translations The Translations menu allows you to define up to 10 cases, each consisting of up to 10 rules in sequential order. Only one case will be applied to a bar code and a case will only be applied if all rules specified in the case are successful - if a rule within a case fails, the entire case fails.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

143

Page 174

Chapter 5: Configuration Translations

144

•

In the Translation menu, tap on the Case # to create rules.

•

Tap on the No rule drop-down menu to display the rules.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual