Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 18 of 44

7535 G2 Hand-Held Computer User Manual: Configuration 5, pages 145 to 154

Pages 145 to 154 of 372, from 7535 G2 Hand-Held Computer User Manual

The original document is the PDF (4.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Teklogix 7535 G2

Page 145

Chapter 5: Configuration Manage Triggers

•

In the Manage Triggers screen you’ll see a list of trigger mappings.

5.6.6.1 Trigger Mappings A trigger mapping is an association between a particular key on the keyboard and a driver or application, the module(s) - sometimes referred to as “trigger consumer(s)” - of the trigger source. Along with keyboard keys, the external trigger (scan button) is software-based. When the specified key is pressed, the owner (for example, a decoded scanner) is sent a message. Important: It is not possible to have two or more identical mappings - for example [F1] cannot be mapped to the Non-Decoded Scanner twice - even if the trigger type is different. A keyboard key that is used as a trigger source will no longer generate key data, or perform its normal function. For example, if the space button is used as a trigger source, it will not be able to send space characters to applications. Double-Click When a key is pressed and released, then pressed again within the configured time (between 0 to 1000 milliseconds), a double-click occurs. See also “Trigger-Press Type” on page 117.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

115

Page 146

Chapter 5: Configuration Manage Triggers

Show All Modules By default, the trigger mapping list only shows active mappings. Mappings for drivers or applications that are not currently active are not normally displayed. By checking this checkbox, all mappings, both active and inactive, are displayed. Add Tapping this button brings up the Add Mapping dialog (see page 116), so that you can add new trigger mappings. Edit Tapping this button brings up the Edit Mapping dialog (see page 116), so that you can edit existing trigger mappings. Remove Tapping this button removes an existing mapping. OK The OK button in the top right of the Manage Triggers screen saves all changes made. If the cancel button X is tapped instead, or the [ESC] key is pressed, all changes made will be discarded. 5.6.6.2 Add And Edit Trigger Mapping These dialogs allow you to add and edit trigger mappings.

116

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 147

Chapter 5: Configuration Manage Triggers

Trigger Key This drop-down list allows you to specify the source of the trigger events, such as the Soft Scan, Left Scan, etc., for the trigger module selected. Note: It is possible to map the same source to different modules (trigger consumers) - for example, to both the Imager and Non-Decoded Scanner. If so, both devices/operations will occur simultaneously. This is not recommended in most cases, especially with devices such as Imagers or RFID Readers. It is also possible to map different sources to the same module (trigger consumer) - for example, two different trigger keys can be mapped to the RFID File System. Add Key Only existing trigger sources are shown in the Source combo-box. To add a new source to this list, tap on the Add Key button. A dialog will pop up and allow you to select the keyboard key to use as a trigger source.

Trigger-Press Type You can enable either an Up/Down or Double Click response to a trigger press. Normally, when a trigger (keyboard key, etc.) is pressed and released, a “trigger down” event is sent to the “owner” - that is, the application receiving the trigger press information - followed by a “trigger up”. If Double Click is chosen in this menu, when the trigger is pressed, released, and then pressed again, a “double-click” event will have occurred. If a mapping with the type Up/Down has also been configured for the same source, it will only receive the first set of trigger events.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

117

Page 148

Chapter 5: Configuration Power Management Properties

Module Trigger This identifies the driver or application receiving the trigger presses. Show All Modules By default, inactive owners are not shown. By checking this checkbox, all owners, both active and inactive, are displayed.

5.6.7

Power Management Properties This icon displays a Power Properties dialog box that indicates the unit’s battery capacity and allows you to manage battery use. •

118

In the Control Panel, choose the Power icon.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 149

Chapter 5: Configuration Power Management Properties

5.6.7.1 Battery Capacity •

In the Power Properties dialog box, open the Battery tab to view battery details.

5.6.7.2 Power Saving Suspend •

In the Power Properties dialog box, open the Suspend tab.

Power Source This drop-down menu allows you to specify whether the unit is using AC Power or Battery Power.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

119

Page 150

Chapter 5: Configuration Power Management Properties

Suspend Timeout Important: Psion Teklogix recommends setting the Suspend value to 10 minutes. To further reduce power consumption, carefully consider the duration of time that the display backlight is ‘on’ (see “Backlight” on page 99). When the 7535 G2 is idle - not receiving any user input (a key touch, a scan, and so on) or system activity (serial data, an activity initiated by an application, and so on) - the handheld uses the value assigned in the Suspend Timeout field to determine when the unit will go to sleep (appear to be off). When the time in the Suspend Timeout field elapses without any activity, the unit enters suspend state. In suspend state, the 7535 G2 CPU enters a sleep state, and the radio is shut off. The state of the device (RAM contents) is preserved. Pressing [ENTER] wakes the system from suspend state. When the 7535 G2 is in suspend state, the network connection will not be broken immediately. If the connection is dropped, you must re-establish the network connection. 5.6.7.3 Suspend Threshold And Estimated Battery Backup

The Suspend Threshold adjustment tells the system when to shut down when the battery drains. If you choose Maximum Operating Time, the unit will run until the battery is completely empty; the RAM is only backed up for a short period of time. If you choose Maximum Backup Time, the hand-held shuts off with more energy left in the battery so RAM can be backed up for a longer period of time.

120

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 151

Chapter 5: Configuration Power Management Properties

Important: Selecting Maximum backup time will reserve approximately 20% of the battery capacity for memory backup. Once the battery is drained, the system RAM memory is lost and the unit must cold boot. In most real-time transaction environments this is not a problem (it only takes a few seconds to cold boot). Batch transaction environments, where data is not saved to a non-volatile memory (such as an SD FLASH card), may need to pay particular attention to this parameter. Psion Teklogix does not recommend the storage of any valuable data in system RAM. The 7535 G2 Windows CE 5.0 environment does not store any critical data in RAM (such as the registry or file system). If your application does not save data to RAM, Psion Teklogix recommends keeping the Suspend Threshold setting as low as possible to maximize battery run time. The Estimated Battery Backup is the amount of battery power that has been reserved or set aside to protect data until a charged battery can be installed in the 7535 G2. When the battery capacity is depleted up to the Estimated Battery Backup reserve specified in the Suspend Threshold menu, the 7535 G2 shuts off automatically and uses the reserve power to preserve the data stored on the computer. Once the 7535 G2 shuts down, it cannot be switched on until a fresh battery is installed, or the unit is inserted in a docking station or cradle. •

Slide the Suspend Threshold button to the right to increase the battery capacity reserved for backup purposes. Data will be preserved to a maximum of 124 hours. • Slide the Suspend Threshold button to the left to decrease the power reserved for backup purposes; this increases the 7535 G2 operating time - the amount of time the unit will operate before shutting down - but reduces the power reserved for backup purposes to a minimum of 24 hours. Internal super-capacitors will protect the data stored in the 7535 G2 while the battery is swapped for a fully charged one.

Important: Once the battery is removed, the super-capacitors will preserve the data stored on the 7535 G2 for approximately 5 minutes. It is critical that you install a charged battery before this time elapses.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

121

Page 152

Chapter 5: Configuration Power Management Properties

5.6.7.4 Calibrate

Tapping in the checkbox next to Allow Battery Calibration allows the battery to be recalibrated only when necessary if the unit is inserted in a Combo Docking station. 5.6.7.5 Advanced

Allow Suspend With: This tab allows you to specify whether or not your unit will enter Suspend state while it is operating with an active PPP connection, network interface, or active TCP/IP connection.

122

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

Page 153

Chapter 5: Configuration Power Management Properties

Low Power Warnings The sliding scale at the bottom of this tab allows you to specify the remaining battery capacity at which a warning message is displayed on the 7535 G2 screen, from 0% to 20%. 5.6.7.6 Devices This tab controls power to individual CF and SDIO slots. Enable or disable the checkboxes as needed, then tap on OK to save your changes.

5.6.7.7 Built In Devices This tab controls power to built-in devices such as Bluetooth. Enable or disable the checkboxes as needed, then tap on OK to save your changes.

Psion Teklogix 7535 G2 Hand-Held Computer User Manual

123

Page 154

Chapter 5: Configuration Stylus Properties

5.6.8

Stylus Properties Note: Touchscreen calibration may not be enabled on your unit. If your screen appears to require recalibration, contact your supervisor. •

In the Control Panel, choose the Stylus icon.

5.6.8.1 Double-Tap •

In the Double-Tap menu, follow the directions to tailor the sensitivity of the stylus when you tap on the touchscreen.

5.6.8.2 Calibration Touchscreens rarely require recalibration. However, if your touchscreen has never been calibrated or if you find that the stylus pointer is not accurate when you tap on an item, follow the directions below. 124

Psion Teklogix 7535 G2 Hand-Held Computer User Manual