Page 263
Chapter 6: Tekterm Application Sending Data To The Host Once the 7535/7530 is configured, an ANSI operation can be selected from the startup “Display Menu”.
6.7.2 Sending Data To The Host Hand-helds running ANSI sessions transmit characters to the host as soon as they are typed. The 7535/7530 provides parameters that determine when the computer transmits characters to the host. The 7535/7530 can be configured to transmit after a number of characters are typed in (the “Xmit Count” parameter) or after some time has elapsed (the “Xmit Wait” parameter), or both. This reduces overhead on the radio link and improves response time. See page 276 for more information about these parameters. You can also determine whether the 7535/7530 transmits immediately after the <ENTER> key, an arrow key, or a function key is pressed. The 7535/7530 computer also responds immediately to the device attribute requests “CSIc”, “CSI0c” and “ESCZ”. Note:
For a more detailed description of the parameter settings for ANSI, refer to “ANSI Settings” on page 268.
6.7.3 Psion Teklogix Keyboard And VT220 Equivalent Keys The Psion Teklogix keyboard differs from most ANSI terminals. Table 6.2 "Psion Teklogix Keyboard And VT220 Equivalent Keys" maps the equivalent VT220 keys.
Psion Teklogix Key
Equivalent VT220 Key
<UP> arrow
Up arrow
<DOWN> arrow
Down arrow
<RIGHT> arrow
Right arrow
<LEFT> arrow
Left arrow
<F1>-<F4>
PF1-PF4
<F5>
None
<F6>-<F10>
F6-F10
<F11>
F11 (ESC)
<F12>
F12 (BS)
<F13>
F13 (LF)
<F14>
F14
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
237
Page 264
Chapter 6: Tekterm Application Block Mode (Local Editing)
Psion Teklogix Key
Equivalent VT220 Key
<F15>
Help
<F16>
Do
<F17>-<F20>
F17-F20
<F21>
Find
<F22>
Insert Here
<F23>
Remove
<F24>
Select
<F25>
Previous Screen
<F26>
Next Screen
<F27>-<F36>
None
Table 6.2 Psion Teklogix Keyboard And VT220 Equivalent Keys
6.7.4 Block Mode (Local Editing) Psion Teklogix 7535/7530s support “block mode” (or Local Editing). Application programs must be specifically written to support this mode. For software that supports this mode, the keys shown in Table 6.3 "Function Of Keys In Block Mode" have special meaning.
Key
Function
<ENTER>
Starts transmission of data.
Function keys
Start transmission of data.
Arrow keys
Move cursor to the next unprotected position in the appropriate direction.
<SHIFT> <RIGHT> arrow
Moves the cursor to the next unprotected area.
<SHIFT> <LEFT> arrow
Moves the cursor to the previous unprotected area.
<DEL> <CLR>
Deletes the character to the left of the cursor, and moves cursor one position to the left. Erases the data in an area and moves the cursor to the first position in the area.
Table 6.3 Function Of Keys In Block Mode
238 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 265
Chapter 6: Tekterm Application Working With Sessions
6.7.5 Working With Sessions Important:
Use only lowercase letters when entering commands at the “TCP >” prompt.
6.7.5.1
Establishing A New Session
•
Press <CTRL>, and type a lowercase a.
At the TCP> prompt: • Type tel in lowercase letters followed by the Host Name or IP address. • Press <ENTER>. • Log in as usual to begin working with the new session.
6.7.5.2
Listing Sessions And Moving To Other Sessions
To list the current sessions: •
Press <CTRL>, and type a lowercase a.
At the TCP> prompt: •
Type sess in lowercase letters, and press <ENTER>.
To move to another session: •
At the TCP> prompt, type sess in lowercase letters followed by the session number to which you want to move. e.g., Type sess 2 to move to session 2.
•
Press <ENTER>.
6.7.5.3
Closing A Session
To close a session: • Press <CTRL>, and type a lowercase a. • At the TCP> prompt, type cl in lowercase letters followed by the session number you want to close. e.g., Type cl 2 to close session 2. • Press <ENTER>.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
239
Page 266
Chapter 6: Tekterm Application Printing A Screen
6.7.5.4
Printing A Screen
To print each line of a screen with a CR/LF between each line: •
Press <CTRL>, and type p.
The screen will be printed using the port configured as “Print”.
6.7.5.5
Smart Echo – Disabling
In some circumstances – like entering a password – you many want to temporarily disable “smart echo”, disguising the characters you type with ‘.’ (periods). • •
Press <CTRL> <ALT> <P>, and type a ‘.’ (period). Type the necessary information using the keyboard, and then press <ENTER> to return to “smart echo mode.
6.8 The Radio Statistics Screen A radio statistics screen is automatically created when the Open Tekterm application is launched. Important:
If you have a 7530 equipped with a Narrow Band radio, refer to “Info Tab” beginning on page 137 for details about accessing the Narrow Band radio statistics screen.
To access the 802.11 radios statistics screen, you’ll need to use the ‘Applications’ menu to assign a radio title: • • • •
In the More Parameters menu, choose Applications. In the Type field, choose RadioStats. In the Title field, type a name for the radio screen – e.g., Radio. Press <F4> to save your changes, and then reset the 7535/7530 – press and hold down the <BLUE> and <ENTER> keys for a minimum of 6 seconds.
240 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 267
Chapter 6: Tekterm Application The Radio Statistics Screen •
In the Display menu, type the letter corresponding to the radio statistics screen. For example, in the sample screen below, you’d type d to display the radio statistics screen. 01 Display Menu A Parameters B TESS C ANSI D Radio
802.IQ Stats Screen 802.IQ Stats AP/Controller MAC 00:00:00:00 Terminal MAC 00:00:00:00:00:00 bootnum: C33B rm 12 xm 7 rb 50 xi 1 ra 7 xa 12 bt 0 xr 1 rt (avg/lst) 10000: 0 fr:00 ar:00 fh:00 ah:00 ca:0 tn:0 sts:0 typ:0 msk:0 Q:0 AcQ:1 TxQ:1 -----Address Info------------Radio Address 0 End of statistics.
•
AP/Controller mac
MAC address of the Teklogix access point/controller with which this hand-held is currently associated.
•
Terminal MAC
MAC address of the hand-held computer.
• bootnum e.g., C33B – the boot number of the network controller. This number increments each time the controller reboots so that hand-helds can detect the reboot when they reinitialize. Psion Teklogix 7535/7530 Hand-Held Computer User Manual
241
Page 268
Chapter 6: Tekterm Application The Radio Statistics Screen • rm number of unique received messages.
• xm number of unique transmitted messages.
• rb number of received beacons. This number should continuously increment.
• xi number of initializations with the network controller.
• ra number of received acknowledgements. (Normally, this number should match the value in xm.)
• xa number of transmitted acknowledgements. (Normally, this number should match the value in rm.)
• bt beacon timeouts. Number of times the beacon has not been received as expected.
• xr number of retransmissions. This number should remain low if radio coverage is adequate.
• rt average round trip time. This number represents the milliseconds taken to send a message and receive a response from the base station.
Cellular Protocol message numbers: • fr forward remote number (hex).
• ar acknowledged remote number (hex).
• fh forward host number (hex).
• ah acknowledged host number (hex).
• ca radio address. This is the Cellular Address, including session number (hex).
• tn host terminal number of session (decimal).
• sts session status (hex).
• typ data stream type (hex).
• msk message mask (hex).
242 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 269
Chapter 6: Tekterm Application The Tekterm Startup Display Menu •
Q memory address of first message in receive queue (i.e. if 0 then the receive queue is empty).
•
AcQ number of messages that have been sent but not yet acknowledged by the Cellular Master (decimal).
•
TxQ number of messages waiting to be sent (decimal).
6.9 The Tekterm Startup Display Menu The values assigned to Tekterm parameters can be viewed and adjusted to optimize communication at the site in which a 7535/7530 is operating. While some parameters are accessible through the “Parameter Manager”, others can be adjusted through the Windows CE .NET Control Panel. This section provides a description of all parameters and how to adjust them. •
Press <CTRL> <ALT> <0> (zero) to work with the ‘Display’ menu.
From this startup menu, you can launch the “Parameters” menu along with TESS and/or ANSI sessions. You can also display the Radio Statistics screen. 01 Display A B C
Note:
Parameters TESS ANSI
Aside from the ‘Parameters’ menu, all other applications listed in the ‘Display Menu’ are created in the ‘Applications’ menu. Refer to “Applications” on page 267 for details.
To launch an application, either type the letter to the left of the application you want to use, or tap the stylus on the item. For example, to display the “Parameters” menu: •
Type the letter ‘a’, or
•
Tap the stylus on the “Parameters” item.
Note:
To return to the ‘Display Menu’, press <F2> – the ‘Previous’ key.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
243
Page 270
Chapter 6: Tekterm Application Working With Menus
6.10 Working With Menus The 7535/7530 offers two ways to navigate menus and choose values – you can use the keyboard, or you can select items by tapping a stylus on the screen. (Keep in mind that some 7535s are not equipped with touchscreens, in these cases, navigation will be limited to the keyboard.) There are four types of parameters: numeric, Y/N, alpha and string entry. Some menus have sub-menus attached to them and others utilize a Control Panel dialog box to make adjustments. Important:
Depending on the method you use when working with menus, review either “Using The Keyboard To Navigate Through Menus” on page 244 or “Using The Touchscreen To Navigate Through Menus” on page 247.
6.10.1 Using The Keyboard To Navigate Through Menus •
Press the <UP> and <DOWN> arrow keys to move the cursor up and down the current menu.
The currently selected parameter name will be displayed in reverse video.
6.10.1.1 Sub-Menus The “»” character appearing to the right of the menu item indicates that it has a sub-menu.
Displaying Sub-Menus To display a sub-menu: •
Use the <UP> and <DOWN> arrow keys to position the cursor on the menu item with the sub-menu you want to display.
•
Press <F1> – the “NEXT” menu function key.
Returning To The Previous Menu •
Press <F2> – the “PREV” function key, or
•
Press <ESC>.
244 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 271
Chapter 6: Tekterm Application Numeric Parameters
6.10.1.2 Numeric Parameters Numeric parameters are displayed in reverse video. To increment or decrement a number: •
Press the <RIGHT> or <LEFT> arrow keys, or
•
Type the desired number in the field. Negative values are entered by typing a “-” (minus) sign and then the number.
•
Press <ENTER>.
Each numeric parameter has a preset range of numbers assigned to it – for example, a preset range of 1 through 10. If you attempt to enter a number which either exceeds 10 or falls below 1, the incorrect value will be rejected – the original value for this parameter, if any, will be displayed.
6.10.1.3 Y/N Parameters Y/N parameters can only be enabled (Y) or disabled (N). To enable or disable a Y/N parameter: •
Press the <RIGHT> or <LEFT> arrow key once, or
•
Type y to enable or n to disable the parameter.
Some Y/N parameters have sub-menus. For these parameters, a double right arrow (») appears next to the “Y” or “N”.
6.10.1.4 Alpha Parameters Alpha characters appear in reverse video in this type of parameter. The allowable values for alpha parameters consist of a predetermined set of acceptable letters or words. To cycle through the set: •
Press the <RIGHT> or <LEFT> arrow keys.
6.10.1.5 String Entry Parameters Important:
For detailed information about using string entry fields to program macro keys, refer to “Macro Control Panel” on page 255.
A sequence or string of characters can be entered in this type of parameter. When a string entry parameter contains data, it is displayed in reverse video. (Empty fields Psion Teklogix 7535/7530 Hand-Held Computer User Manual
245
Page 272
Chapter 6: Tekterm Application String Entry Parameters are not displayed in reverse video.) The methods that can be used to enter information in string entry parameters are described in this section. In string entry parameters, the <UP> arrow, <DOWN> arrow, <ENTER> and <BKSP> keys have the following functions: •
The <UP> and <DOWN> arrow keys move the cursor between entry fields in the direction of the arrow.
•
<ENTER> completes the entry field.
•
<BKSP> deletes the character to the left of the cursor.
•
<DEL> (key combination <BLUE> <BKSP>) clears the entire field.
Choosing An ASCII Character With The Arrow Keys Important:
Make sure the <CTRL> and <SHIFT> keys are turned off!
By pressing either the <RIGHT> or <LEFT> arrow key, you can cycle through a set of printable characters not directly accessible from the keyboard. •
Press the <RIGHT> arrow to display the next character in this sequence, and the <LEFT> arrow to display the previous one.
Adding Additional ASCII Characters When you’ve chosen an ASCII character and want to add another one in the same field, the cursor must be moved to the right of the existing character. Normally, pressing the <RIGHT> arrow key moves the cursor to the right, but in a string entry field, pressing the <RIGHT> arrow key cycles through the available ASCII characters instead. If you’ve already chosen an ASCII character and want to add another one in the field, you need to take a few extra steps to move the cursor to the right. To add another ASCII character in the string entry field, next to the one you’ve already chosen: •
Type a numeric character – for example, type the number 7.
•
Next, press the <BKSP> key.
246 Psion Teklogix 7535/7530 Hand-Held Computer User Manual