Page 253
Chapter 6: Tekterm Application The Tekterm Status Area
6.5 The Tekterm Status Area Tekterm provides a status area just above the softkey labels. The status area indicates the operating condition of the hand-held.
Figure 6.2 Status Area The security level assigned within the Tekterm application is displayed in the status area. One of the following is displayed – Supervisor or Teklogix.
6.6 TESS Emulation TESS (Teklogix Screen Subsystem) is the normal operating mode of Psion Teklogix computers. Teklogix protocol emulation software resident on network controllers or a Psion Teklogix Software Development Kit (SDK) and installed in the host converts host screens to TESS commands. The 9150 Access Point is also equipped with protocol emulation software. Note:
If the message “RESET: Press Enter” flashes at the bottom of the TESS screen when you turn on the 7535/7530, press the <ENTER> key once.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
227
Page 254
Chapter 6: Tekterm Application Configuration
6.6.1 Configuration Note:
Each TESS session must have a unique name assigned to it. The title you assign will be displayed in the Display Menu.
The process of renaming an existing TESS session and adding a new session is described in the section titled, “Applications” on page 267. A unique number must be assigned in the “Terminal #” parameter for each TESS session. Refer to “Terminal #” in the section titled “TESS Settings” on page 285 for details.
6.6.2 Working With Multiple Sessions Note:
The “Screen Switch” parameter must be set to “Y” in order for the operator to switch between sessions. Refer to “Screen Switch” on page 258 for details.
If you are using Windows CE .NET 4.2, you can press <CTRL> <ALT> followed by the application number to move between sessions. For example: •
Press <CTRL> <ALT> <2> to switch to Open Tekterm, application 2.
•
Press <CTRL> <ALT> <1> to switch back to Open Tekterm, application 1, and so on.
6.6.3 The Field Types Fixed Field – displays information that cannot be changed from the keyboard. Entry Field – allows the operator to enter data. This type of field is usually shown as: “........” Match Field – the host computer loads data in the format of the expected entry. If the entered data does not match the expected format, the unit emits a long beep. Auto-tab Field – automatically moves the cursor to the next field when the current field is filled. Bar code only Field – is filled with data from a bar code reader. Keyboard entries are not accepted in this type of field. Serial I/O Field – is filled with data coming from a serial port. Keyboard input is not accepted in this type of field.
228 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 255
Chapter 6: Tekterm Application IBM 5250 Emulation Keys
6.6.4 IBM 5250 Emulation Keys The following keys allow the Psion Teklogix computer to better emulate the functions of a true IBM 5250 terminal. Note:
These keys are active at all times in TESS applications.
Key Function
Key Sequence
Cursor Movement
Cursor moves to the first position in the next Field Advance <BLUE> <O> input field. If already in the last field, the cursor or Tab (PgDn key) moves to the first input field on the screen. Cursor moves to the beginning of the current Field Back<BLUE> <I> field. If already in the first position, the cursor space (PgUp key) moves to beginning of the previous field. Current field is cleared from the cursor position <BLUE> <P> to the end of the field, and the cursor moves to the Field Exit (End key) next input field. <BLUE> <N> Cursor moves to the first input field on the Home (Home key) screen.
6.6.5 Data Entry The 7535/7530 accepts data until the operator presses a key that sends a transmission to the host computer. The following actions cause the 7535/7530 to transmit: •
Pressing a function key or the <ENTER> key (which is considered to be <F0>) causes the hand-held to transmit.
•
Completing data entry into a “transmit on entry” field also causes the hand-held to transmit.
There are several ways to configure the 7535/7530 to complete a data field: •
Pressing <ENTER> after entering data.
•
Pressing a function key after entering data.
•
Pressing an arrow key after entering data.
•
Filling an auto-tab field.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
229
Page 256
Chapter 6: Tekterm Application TESS Edit Modes And Cursor Movement
6.6.5.1
TESS Edit Modes And Cursor Movement
The TESS editing modes and cursor movements in each type of mode are described in the table below. Press <CTRL> f to enter field mode. In this mode, once data entry Field mode
Fcursor mode
Insert mode
Replace mode
Note:
into a field has been completed, the entry cannot be changed without retyping the entire field. In field mode, the <RIGHT> and <LEFT> arrow keys do not perform any functions. Pressing the <UP> or <DOWN> arrow key completes the entry field and then, moves the cursor to the previous or next field. Press <CTRL> u to enter fcursor mode. In this mode, once data entry into a field has been completed, the entry cannot be changed without retyping the entire field. In fcursor mode, the <UP>, <DOWN>, <LEFT> and <RIGHT> arrow keys move the cursor between fields. Press <CTRL> i to enter insert mode. In this mode, data can be entered between two characters that have been previously entered. In insert mode, the <RIGHT> and <LEFT> arrow keys move the cursor right and left within a field. The <UP> and <DOWN> arrow keys complete the entry field and move the cursor to the previous or next field. Press <CTRL> r to enter replace mode. In this mode, data can be entered over previously entered characters. In replace mode, the <RIGHT> and <LEFT> arrow keys move the cursor to the right and left within a field. The <UP> and <DOWN> arrow keys complete the entry field and move the cursor to the previous or next field.
When the “Enter on Arr” parameter is disabled (set to “N”), the <UP> and <DOWN> arrow keys do not complete an entry field. Refer to page 298 for details about this parameter.
230 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 257
Chapter 6: Tekterm Application <DEL> Key Behaviour In TESS
6.6.5.2
<DEL> Key Behaviour In TESS
Field mode
Replace mode
Insert mode
Fcursor mode
• In a left justified field, the <DEL> key erases all characters in the field and places the cursor in the left most position of that field. • In a right justified field, the <DEL> key erases all characters in the field and places the cursor in the right most position of that field. • If the <DEL> key is used to clear data in a field that has been pre-filled by the host application, the field is flagged as modified and the updated information is sent to the host in the next response message. • In both left and right justified fields, the <DEL> key erases characters beginning from the current cursor position to the end of the field. The cursor remains in the same position in the field. • If the <DEL> key is pressed while cursor is in the right most position in the field, the 7535/7530 emits a keyboard error beep. • If the <DEL> key is used to clear data in a field that has been pre-filled by the host application, the field is flagged as modified and the updated information is sent to the host in the next response message. • In both left and right justified fields, the <DEL> key erases the characters from one character position to right of the cursor to the end of the field. • If the <DEL> key is pressed while the cursor is in the right most position in the field, the 7535/7530 emits a keyboard error beep. • If the <DEL> key is used to clear data in a field that has been pre-filled by the host application, the field is flagged as modified and the updated information is sent to the host in the next response message. •Refer to “Field Mode” at the beginning of this table. The <DEL> key operates in the same manner in “Fcursor mode” as it does in “Field mode”.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
231
Page 258
Chapter 6: Tekterm Application <BKSP> Key Behaviour In TESS
6.6.5.3
<BKSP> Key Behaviour In TESS
Field mode
Replace mode
• In a left justified field, the <BKSP> key erases the character directly to the left of the cursor and then moves the cursor one position to the left. When the last character in the field is deleted, the field displays the value that it contained before it was modified, and the field is opened. • In a right justified field, the <BKSP> key erases the character on which the cursor is positioned and shifts the remaining characters to the right by one position. When the last character in the field is deleted, the field displays the value that it contained before it was modified, and the field is opened. • If the <BKSP> key is pressed when the field is empty, the 7535/7530 emits a keyboard error beep. • The <BKSP> key does not delete data pre-filled by the host application. • If the <BKSP> key is pressed in a field that has not been modified, the 7535/7530 emits a keyboard error beep. • If data is entered into a field and is then deleted before the field is completed, the field remains unmodified when the cursor leaves the field or when the screen is transmitted. • In a left justified field, the <BKSP> key erases the character on which the cursor is positioned unless it is one position to the right of the last character in the string; in this case, the <BKSP> key erases the character to the left of the cursor. • In a right justified field, the <BKSP> key erases the character on which the cursor is positioned. The remaining characters are then shifted to the left of the cursor, and the cursor is shifted to the right by one position. • If the <BKSP> key is pressed while the cursor is in the right-most character position of the field, the cursor does not shift to the left when that character is erased; it remains in the right most position in the field. • When the last character in a field is erased, the field remains empty – that is, any pre-filled data is not displayed. Pressing the <BKSP> key in the empty field results in a keyboard error beep. • The <BKSP> key can delete data pre-filled by the host application. • If data is entered in a field and is then deleted before the field is completed, the field remains unmodified when the cursor leaves the field or when the screen is transmitted.
232 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 259
Chapter 6: Tekterm Application TESS Status Message
Insert mode
• In a left justified field, the <BKSP> function erases the character on which the cursor is positioned, unless it is at the right end of the character string; in this case, it erases the character to the left of the cursor. When the last character in a field is erased, the field remains empty, and any further <BKSP> functions in the empty field result in a keyboard error beep. • In a right justified field, the <BKSP> function erases the character that is to the right of the cursor and then shifts the data remaining to the right one position. • If the <BKSP> key is pressed while the cursor is in the right-most character position of that field, the cursor does not shift to the left when that character is erased; it remains in the right-most position in the field. • When the last character in a field is erased, the field remains empty – i.e. any pre-filled data is not displayed. Pressing the BKSP key in the empty field sounds a keyboard error beep. • The <BKSP> key can delete data pre-filled by the host application. • If data is entered into a field and then deleted before the field is completed, the field remains unmodified when the cursor leaves the field or when the screen is transmitted.
Fcursor mode
• Refer to “Field Mode” at the beginning of this table. The <BKSP> key operates in exactly the same manner in “Fcursor mode” as it does in “Field mode”.
6.6.6 TESS Status Message •
Press <CTRL> <S> to continuously display the status message in the lower left corner of the screen.
•
Press <CTRL> <W> to make this message appear only when the 7535/7530 locks. The message should look similar to the sample below: V6.0 fld 0.6
“V6.0” is the TESS version number. “fld” indicates that TESS is currently in field mode. Insert and replace mode are represented as “ins” and “rep” respectively. The number “0.6” indicates the response time of the last transmission in seconds. Press <CTRL> <T> to display the unit number instead of the TESS version number.
Psion Teklogix 7535/7530 Hand-Held Computer User Manual
233
Page 260
Chapter 6: Tekterm Application Lock Messages
6.6.7 Lock Messages When information is transmitted to the host computer, the keyboard locks to prevent further data entry until the 7535/7530 receives a reply. A locked state is indicated by either “LOCK-B” (base) or “LOCK-H” (host) in the lower left corner of the display. When the reply is received by the 7535/7530, the lock message disappears and the keyboard can be used again.
6.6.8 Control Commands A group of <CTRL> key commands can be used within TESS to dictate how the 7535/7530 will operate under a variety of conditions. • <CTRL> <P> – Reprints the last print page sent from the host. This key combination will not print anything if a print page from the host was not previously received at the hand-held. • <CTRL> <S> – Displays the hand-held status continuously. Below is a sample status line as it might appear at the bottom of your screen: Lock-B/Lock-H
•
• enh
“application name”
<CTRL> <W> – Displays the 7535/7530 status when the unit is in “Lock B” or “Lock H” mode. The status line would be similar to the sample above. <CTRL><T> – Displays the 7535/7530 status with the terminal number instead of the name. Lock-B/Lock-H
• fld rep
“terminal nn”
<CTRL> <H> – Displays a menu of available hosts.
6.6.9 Resetting A TESS Session Resetting a TESS session requires that <CTRL> C be pressed three times within a two second period to generate the “RESET – User request” message. •
Press and hold down the <CTRL> key, and press the <C> key three times within a two second period.
•
Press <ENTER>.
This procedure restarts the TESS session without affecting the rest of the 7535/7530. 234 Psion Teklogix 7535/7530 Hand-Held Computer User Manual
Page 261
Chapter 6: Tekterm Application The Local Menu
6.6.10 The Local Menu The host can store local procedures in the 7535/7530 for use when the unit is off-line. A menu of these procedures appears whenever <CTRL> <L> is pressed (see “Figure 6.3” on page 235). • Press the function key corresponding to the procedure you want to perform. Local procedures will not function when the “Lcl Process” and “Queuing” parameters are disabled (see “Lcl Process – Save on Reset” on page 293 and “Queuing” on page 292). Although using local procedures eliminates the advantages of an on-line 7535/7530, it allows work to continue when the host is unavailable. The “LOCK-B/H” messages are replaced with “NEXT-B/H” in this mode. LOCAL MENU F1 F2 F3 F4 F5 F6 F7 F8 F9 - Select Host
Figure 6.3 Local Menu
6.6.11 Selecting Another Host Computer •
Press <CTRL> <H> or <F9> from the local menu to display a menu of available hosts.
This menu appears only when more than one host is available. Select Host: ...... F1 - Host 1 F2 - Host 2
Figure 6.4 Select Host Screen Note:
This feature will not function when the “Lcl Process” and “Queuing” parameters are disabled (see “Lcl Process – Save on Reset” on page 293 and “Queuing” on page 292). Psion Teklogix 7535/7530 Hand-Held Computer User Manual
235
Page 262
Chapter 6: Tekterm Application Queuing Mode
6.6.12 Queuing Mode In some applications, queuing mode can decrease the computer lock time. In queuing mode, the host computer may send several pages to a 7535/7530 without waiting for a response. These pages are stored in a queue within the hand-held. The operator completes the entries on the first page and then, presses a function key. The 7535/7530 simultaneously transmits to the host and displays the next page in the queue. The computer does not lock, allowing the operator to enter data on the next page immediately. This continues as long as there are pages in the queue. Queuing mode is used for repetitive tasks, and the queued screens look identical. The 7535/7530 displays a “Next” message indicating that a new page is on the display. “Next” messages also contain information about radio communications: “NEXT-B” indicates that the 7535/7530 has data to transmit to the base station. “NEXT-H” indicates that the base station has acknowledged a transmission. Unlike lock messages, “Next” messages do not lock the keyboard. Keying is allowed while “Next” messages are displayed. While queuing mode may improve apparent response time, it can present difficulties to hosts that are operating in real time. It should only be used after careful consideration of the host environment. The 7535/7530 must be configured for queuing mode (see the “Queuing” parameter on page 292). Additional information on queuing can be found in the TESS (Teklogix Screen Subsystem) Manual.
6.7 ANSI Emulation The Psion Teklogix 7535/7530 in ANSI mode operates like most other ANSI terminals. This means software that supports ANSI terminals requires little or no changes.
6.7.1 Configuration To configure the 7535/7530 for ANSI mode, the “Name” and “Type” of session – in this case, ANSI – must be specified in the Applications menu. This menu is described in the section titled, “Applications” on page 267. Next, a unique number must be assigned using the “Terminal #” parameter. This number should be unique across the entire system – that is, each 7535/7530 and each application session in each 7535/7530 across your system must have a unique number assigned. This parameter is described in the section titled “ANSI Settings” on page 268. 236 Psion Teklogix 7535/7530 Hand-Held Computer User Manual