Page 100
-
Source check
File check
Enables checking: Primary source is the input source: what reader is operated. According to this the software will apply accordingly. The reader number is a secondary source. Reader Status code is unique for each output type as follows: Readers- E= read error, D=data read OK Keypad- N=numeric or Enter key (If only Enter then IL=0) Sensors- A= Active, P= Passive Note: IL=0 Printer- A= Active, P= Passive Enables validating an authorized list with one of the tables on the Locate section. Under File choose the specific file.
Query
A query is sent to the software that is performing an online scan - using SYServer. Write last Enables saving the last transaction setup in a transaction temporary file for later display as t he employee’s last transaction. 98
Page 101
-
Store Enables adding transaction data to a buffer. transaction Write Enables saving all transaction steps (see transaction Transaction folder) in the terminal’s memory. Later this data can be collected by the host. Transaction In this screen the user can define a multi-step transaction, combining Test, Input and prompt message definitions. The screen shot below demonstrates the enrolment procedure that requires a supervisor card to be swiped first.
General Combines the transaction definitions with a function key on the terminal’s panel
99
Page 102
-
.
Define all hardware parameters: Key function- Determine function allocation to terminal keys. Display parameters- What error message will be displayed on the prompt. Also you must choose a date/time format as per the terminal you are using as follows: DD/MM MM/DD HH:mm HH:mm a/p 711/ DD/MM 715 HH:mm MM/DD HH:mm DD/MM, a/p HH:mm MM/DD, a/p HH:mm
777/ 780
100
Page 103
-
Global parameters- Timing of terminal activities. Sensor parameters- sensor operational parameter. Error notification- Setting-up error indicators. Weekly Combines General definitions of the terminal function keys with a day of the week. Thus, the terminal can be used differently for each day.
101
Page 104
-
Appendix G -Wiegand Algorithms The following decoding methods can be used for the terminals Wiegand interface: 32 bit Algorithm 2: Input: 1 (Even Parity bit) - 15 bits - 15 bits - 1 (Odd Parity bit) Output - Facility code 5 bytes (15 bits) Card Number 5 bytes (15 bits) Algorithm 3: Input: 1 (Even Parity bit) - 10 bits - 20 bits - 1 (Odd Parity bit) Output - Card number 6 bytes (only 20 bits are decoded) Algorithm 4: Input: 1 (Even Parity bit) - 6 bits - 24 bits - 1 (Odd Parity bit) Output - Card number 8 bytes (only 24 bits are decoded)
102
Page 105
-
33 bit Algorithm 0 Input: 1 (Even Parity bit) - 7 bits - 24 bits - 1 (Odd Parity bit) Output - Facility code 2 bytes (7 bits) Card Number 8 bytes (24 bits) Algorithm 1 Input: 1 (Even Parity bit) - 10 bits - 21 bits - 1 (Odd Parity bit) Output - Facility code 4 bytes (10 bits) Card Number 7 bytes (21 bits) Algorithm 2 Input: 1 (Do not check parity bit) - 10 bits - 21 bits - 1 (Do not check parity bit) Output - Facility code 4 bytes (10 bits) Card Number 7 bytes (21 bits) 36 bit Algorithm 4 Input: 1 (Even Parity bit) - 6 bits - 12 bits - 16 bits - 1 (Odd Parity bit) Output - Factory code 2 bytes (6 bits) Facility code 4 bytes (12 bits) Card number 5 bytes (16 bits) 103
Page 106
-
Synel Industries Ltd. 2 Hamada St. POB 142, Yokneam Industrial Park, Israel, 20692 Tel: +972-4-959 6777Fax: +972-4-959 0729 Site: www.synel.com Tel-Aviv BranchTel: +972 9 775 0400 UK BranchTel: +44-181-900 9991 NA BranchTel: +1-905-678 2605