Page 91

-

Printer Notes This feature is used for printing labels (For example.: meals). First you must go to Set-up | Program Configuration | Printer and define the printer type you are using in your organization. There are several predefined default printer definitions. If none match your specific printer brand, you should define printer parameters.

89

Page 92

-

Test This is a mini set-up table for activities and terms to be performed on the transactions. It is possible to perform one activity or a sequence of several activities. Some of the relatively simple activities are: saving transactions, employee access/other validation, displaying specific timed messages. Some of the more complex activities are: calculation activities (sum, subtract, multiply, compare etc.), variable to variable, inter-buffer activities. The Test table is divided into 2 parts:

90

Page 93

-

1

2 1. The header is the test name, it is recommended that the given name will portray the purpose of the test, see above screen. A new header can be created by either clicking the New button or the key. 2. The base part is where actual definitions are set, when double clicking a row the following screen appear

91

Page 94

-

:

Step 1:Fill-in a test name and number. Step 2:The templates are comprised of different activities: Most templates are divided into 3 parts: Operation- A check to be performed, different from template to template. OK- Further to the operation how to confirm or what other activities will follow. Similar for most templates. Fail- Further to the operation how to indicate that the operation has failed. Similar for most tem-

92

Page 95

- plates. The OK/Fail sections screens are displayed below:

Display message Display end Relay Buzzer alert Buzzer OK Buzzer error Wait Write last transaction Store transaction

Enables choosing a constant message from the system messages list. Enables displaying variables of input data. Enables activating a relay. Enables activating an alert buzzer. Enables activating an OK buzzer. Enables activating an error buzzer. Waiting time between transactions. Transmits data that was stored in a designated directory, to be displayed a later stage. Determine what data will be stored. 93

Page 96

-

Write transaction Go to module End

Transmits data that was stored to the terminal’s memory. Cannot be displayed. Enables a cyclic flow to the same transaction. The terminal reverts to the defined default function.

94

Page 97

-

Buffers: What data will be displayed on the terminal’s prompt: N - None No check will be performed. I - Input data The last value that was received by the terminal. L - Input length The Number of designated spaces for counting total value length. P - Input From which source the last input has arrived, source upto four spaces: 1st=type, 2nd+3rd=reader number, 4th=status. F - File buffer The results of a table search (either employee or valid)= the last record (approx. 30 spaces). S - File status The status after performing the last command. R - Transaction Before storing the transaction it can be compared. C - Constant Free text to be filled in Constant field below.

95

Page 98

-

Below find an outline of defining Operation for templates: Length check

Check value

Defines the input length limitation (KB, card number, identification ID etc.) and the offset of that input number. Enables comparing field variables.

96

Page 99

-

Operate

Enables performing various calculations between buffers. i.e.: This feature is useful when printing, for placing variables in the printer buffer: AD= summary, SU= subtract, MV= Move, AN=Pairing bytes logically, OR= alternating 2 bytes logically, XR=Exclusive XOR operator, NU=numeric check