Page 81

WSS 1000 Product Reference Guide

Note: Scanner use depends on the application. The procedure for your scanner may differ. Table 6-2. LED Indications (Subject to Application Use) Message

Green LED

Red LED

Successful Decode

On

Off

Scanning

Off

On

Scanner in Blink Mode

Off

Blinking

Unit Off

Off

Off

Scanning Considerations Usually, scanning is a simple matter of aim, scan, and decode, and a few trial efforts master it. However, two important considerations can optimize any scanning technique, angle and range.

Angle Scanning angle is important for promoting quick decodes. When laser beams reflect directly back into the scanner from the bar code, this specular reflection can actually “blind” the scanner. To avoid this, scan the bar code so that the beam does not bounce directly back. But don’t scan at too oblique an angle; the scanner needs to collect scattered reflections from the scan to make a successful decode. Practice shows what tolerances to work within.

Range Any scanning device decodes well over a particular working range (minimum and maximum distances from the bar code). This range varies according to bar code density and scanner optics. Scanning within range results in quick, constant decodes; scanning too close or too far away prevents decodes. You need to find the right working range for the bar codes you are scanning. The best way to specify appropriate working range by bar code density is through a decode zone chart. The decode zone plots the scanner’s working range as a function of

6-12

Page 82

Operating the WSS 1000 minimum element widths of bar code symbols. Refer to Appendix A for the RS 1 and WS 1200 decode zones.

Communications Connecting Cable for Data Communications to a Host Computer 1. Plug serial cable (RS-232) into the communication port located on the right side of the back of the single-slot cradle, or on the left end of the 4-slot cradle. 2. Connect the other end of the cable to the serial (COM) port of the host computer, modem, or printer. Note: In most cases, you must use a null-modem cable. 3. Place the WWC 1000 in the cradle. The amber indicator lights. 4. Press the appropriate key on the WWC 1000, as required by the application. 5. The cradle’s COM indicator blinks when communications begin. Note: Do not remove the wrist computer while the cradle’s COM light is blinking. 6. When communications are complete, the COM light stays on steady.

Wireless Printing Note: Wireless printing is applicable only to the WWC 1049, and works only with applications modified to support wireless printing such as STEP and TNClient. Any application developer can create an application using wireless printing using the Series 3000 ADK. The WWC 1049 can perform wireless printing with Comtec’s portable printers such as the MP5033 if: •

Print support is included with the application loaded on the terminal.

•

The terminal is within range of a supported wireless printer.

Refer to the documentation for your application and to the Series 3000 Application Development Kit for more information on printing. 6-13

Page 83

WSS 1000 Product Reference Guide

6-14

Page 84

Chapter 7 Maintainance and Troubleshooting Cleaning Wrist Computer To clean the wrist computer, use a clean, soft cloth dampened with a mild cleaner such as soap and water. Do not use abrasive paper, cloth, or abrasive/corrosive cleaners. Clean the keypad and scanner triggers, and wipe the display window with lens tissue.

Wrist Mount Remove the bar from the wrist mount. Hand wash the fabric mount with warm water using a mild detergent and air dry (see tag on mount for washing instructions).

Ring Scanner Wipe the scanner window periodically with a lens tissue or other material suitable for cleaning optical material such as eyeglasses.

Caution Do not pour, spray, or spill any liquid onto any part of the wrist computer or ring scanner, particularly the scanner or scan element components.

Ring Mount To clean the ring mount, use a clean soft cloth, dampened with a mild cleanser, such as soap and water. Do not use abrasive paper, cloth, or abrasive/corrosive cleaners. 7-1

Page 85

WSS 1000 Product Reference Guide

WS 1200 Scanner Wipe the scanner window periodically with a lens tissue or other material suitable for cleaning optical material, such as eyeglasses.

Caution Do not pour, spray, or spill any liquid on the scanner.

WS 1200 Mount Periodically hand wash the WS 1200’s mount in warm water with a mild detergent and air dry.

Storage If the system is not going to be used for more than a week, store it in a cool, dry place, away from dust. Remove the battery and repack the wrist computer and scanner in the original shipping container. For a storage period of a few days, the battery pack can remain in the wrist computer. If the battery is left in the wrist computer for an extended period of time, data stored in memory may be lost. To avoid losing data, keep the batteries charged, and be sure to transfer any data before storing the wrist computer.

Replacing the WS 1200 Protective Cap After extended use in harsh environments, the protective cap on the WS 1200 may need to be replaced. To replace the cap that covers the scanner: 1. Remove all cables connected to the scanner. 2. Push up on the recesses between the cap and the scanner (located underneath the scan window) until the tabs on the scanner pop out .

Figure 7-1. Removing cap 7-2

Page 86

Maintaining the WSS 1000

3. Grip the exposed sides of the scanner and pull the scanner out of the cap. 4. Push the scanner into the back of the new cap so the ports appear through the back opening of the cap.

Figure 7-2. Backing Scanner into New Cap 5. Push the front of the scanner into the cap until it snaps into place.

Figure 7-3. Pressing Scanner into Cap

7-3

Page 87

WSS 1000 Product Reference Guide

Error Messages If ERR3000 is loaded in the system configuration, the wrist computer displays the following messages to indicate error conditions that affect system performance. A message is usually accompanied by one or more beeps, after which the system returns to its previous status. The application can change the actual wording of the messages or disable messages. The messages listed in Table 7-1 are representative. Refer to the application’s documentation for further information. Table 7-1. Error Messages Message

7-4

Explanation

Low Battery

The battery pack should be recharged or replaced soon.

Dead Battery

Replace or recharge the battery pack immediately. After this message is displayed, the system shuts off. You may not be able to power it on again until the battery pack is charged.

Power Fault

The last power off was caused by a power failure. This occurs, for example, if the battery pack is removed while the wrist computer is on or the batteries fail suddenly.

Page 88

Maintaining the WSS 1000

Communication Status Codes The program loader status code consists of four hexadecimal digits which indicate whether or not the transfer was successful, and if not, the source of the communications error. A status code of 0000 indicates success; any other code indicates failure. Table C-1 lists the failures associated with the status codes. The values are additive. Table G-2. Communications Status Codes Status Code

Meaning

0002

Receive overrun error

0004

Receive parity error

0008

Receive framing error

0010

Programming voltage not present

0020

Data Set Ready or Carrier Detect not detected on open

0080

ABORT key hit during comm

0100

Insufficient NVM for image

0200

Illegal Intel hexadecimal record

0400

Unsupported Intel record

0600

NVM EEPROM failed to erase

0800

Receive time-out error

1000

Control start character time-out

2000

Clear To Send inactive time-out error

4000

Receive buffer full

7-5

Page 89

WSS 1000 Product Reference Guide

Troubleshooting Start-up Failure Problems are most frequently start-up failures. If cold booting the wrist computer does not start the application successfully, either the application, the system software, or the system is malfunctioning. If you can boot the system to command mode, try the following: •

Use Program Loader to download a new version of the software to NVM. This procedure is described in Chapter 3, Batch and Spectrum One Initialization.

•

Use Self Test to check system hardware operation. The Self Test procedure is described later in this chapter. After downloading new software, warm boot the wrist computer as described in Warm Boot on page 6-3.

Boot Failure Messages During a cold boot, the system briefly displays a status line for each driver as it loads, in the format: 0:Driver

#.##

The line shows a status value, usually 0, followed by the name and version number of the driver. If the system halts at one of these lines and displays a status value other than 0, the displayed device driver did not load properly. If such a failure occurs, cold boot the wrist computer again. If this does not solve the problem, call the Symbol Support Center. More troubleshooting information is found in the documentation listed in Related Publications on page xi.

7-6

Page 90

Maintaining the WSS 1000

Spectrum24 Terminal Typical initialization and operating problems and solutions for Spectrum24 terminals are provided in Table 7-3. Table 7-3. Troubleshooting Spectrum24 Terminals Problem

Explanation/Action

Out of range

Terminal is out of the Access Point’s range. If you move the terminal during initialization, the terminal may be out of range of the AP and unable to complete the initialization process. Move back in range and repeat the initialization process.

Startup process fails

Boot server type (BOOTP or DHCP) doesn’t exist. Verify that boot server is operating and able to respond to TCP/IP BOOTP or DHCP requests from the terminal.

Low Battery Message

Place the terminal in a cradle and recharge battery. OR Power terminal off and replace battery.

Battery is dead

Battery not replaced after receiving low battery message or terminal left on for more than 24 hours. Recharge or replace the battery.

Terminal disassociated from Access Point

Application does not respond to interactive operations. Applications using internal batch mode continue to function until required to transmit by radio, then fail to work. No message displayed.

7-7