Self Test Function The WWC 1000 wrist computer includes a series of self tests which verify that terminal hardware components are operating properly. Run self test if you suspect a problem with the hardware. Except for keyboard testing, no operator input is necessary after selecting a test screen.
Running the Self Test Access the Self Test function from the Command Mode menu: 1. Boot to command mode (refer to Chapter 6, Operating the WSS 1000 for boot sequences). 2. On the Command Mode screen, use the UpArrow or DownArrow to scroll through the options. 3. Highlight Screen Test and press <ENTER>.
Self Test Summaries The Self Test is divided into the following functions or screens: Config Screen 1 - Reports the version, time, and date. Config Screen 2 - Reports information on the keyboard and display. If a laser scanner is attached, the test reports if the trigger is pulled or not. Config Screen 3 - Reports the main battery condition, current power source, and status of the serial ports when a loopback connector is used. Memory Screen - Tests ROM, RAM, and EMS (Expanded) memory, and reports the amount of RAM and EMS. Fill Screen - Fills the entire screen with a test pattern to verify that the entire screen displays. Set RTC Screen - Sets the time and date settings of the real-time clock. Serial ID Screen - Reports the unique identifier for the “flash” memory chip installed in the wrist computer.
7-8
Page 92
Maintaining the WSS 1000
Keyboard Test Keyboard testing can be performed while the wrist computer displays Config Screen 1 results. Test any keys except <Right Alpha Shift>. When you press a key, the corresponding scan code is displayed on the top row to the right of the test name. For the codes for each key on the 27-key keyboard, refer to the scan codes for the unmodified, right unmodified, and left unmodified keyboards.
Exiting Self Test The test loop continues updating the time and battery status and processing keystrokes. To end the test, press <CLEAR> or <Right Alpha Shift><BKSP>. The display returns to the Command Mode menu.
Memory Transfer Program Command Mode includes a memory transfer utility that transfers data from the wrist computer to a host PC for program troubleshooting. Programmers can analyze an application using tools provided in the Series 3000 Application Development Kit and described in the Series 3000 Application Programmer’s Reference Manual.
Cradle Setup 1. Verify that the cradle is properly connected to the PC, as covered in Chapter 2, Cradle Setup and Battery Charging. 2. Place the wrist computer in the cradle. 3. Power on the host PC.
Set Communications Parameters Host 1. Start the Communications program on the host PC. 2. Set up the host communication parameters (these parameters must match the wrist computer’s parameters). At the DOS prompt on the host, enter: RCVHEX <filename.hex> <baud rate> <comport#>
7-9
Page 93
WSS 1000 Product Reference Guide
Typical parameters are: 38400 bps 7 bit data Odd parity Xon/Xoff flow control
Wrist Computer 1. Boot the wrist computer to Command Mode (refer to Boot to Command Mode on page 6-5 for the appropriate key sequence). 2. Select the Memory Transfer function from the Command Mode menu. Use UpArrow or DownArrow to scroll through the command mode options until Memory Transfer is displayed, and press <ENTER>. 3. Select the range of memory to transfer by pressing the first letter of the desired range (All, Range, or None), or use the UpArrow or DownArrow and press <ENTER>. If you select All, the program skips to the range verification screen (step 7). If you select Range, the screen displays: RAM Use Arrow Keys Start End 00000 9FFFF
4. Specify a range of RAM by setting the Start and End addresses. Œ Use RightArrow and LeftArrow to move the cursor to the digit to be changed Œ Use UpArrow and DownArrow to change the values. Type a range and press <ENTER>. 5. Specify a range of NVM to transfer. Choose All or None. 6. If the system has EMS installed, it prompts for the range to transfer (otherwise, the program skips this screen): EMS Use arrow keys Start End
The range is specified in page numbers (16 KB per page). Use RightArrow and LeftArrow to move between the Start and End values. Use UpArrow and DownArrow to change the page number value. 7-10
Page 94
Maintaining the WSS 1000
Set the range and press <ENTER>. 7. The wrist computer displays a range verification screen. For example: RAM 0000 3FFF NVM C839 DFFF EMS None Correct?
If the values are correct, press <ENTER>. If the values are not correct, press <CLEAR> to clear the fields and select new values. 8. Specify the baud rate. Use the up and down arrows to scroll through the list of baud rates until the correct rate is displayed, and press <ENTER>. (Flow control may be necessary at 38400 bps and higher.) 9. Specify the data bits. Press <7> or <8>, or use UpArrow and DownArrow to display 7 or 8, and press <ENTER>. Note: If you select 8 data bits, the program selects No parity and skips the next screen. 10. Specify parity type. Use UpArrow and DownArrow to display a parity option, or press the first letter of a parity option (Even, Odd, None, Space, or Mark) and press <ENTER>. 11. Set flow control. Use UpArrow and DownArrow to display the flow control options, or press the first letter of an option (None, Xon/Xoff, or RTS/CTS) and press <ENTER>.
Start Communications 1. The wrist computer is ready to send the data to the host PC and displays: Comm Parameters Start? <ENT>
2. Verify that the host is ready to receive data. 3. Press <ENTER> on the wrist computer. While data is being transferred, the wrist computer displays a report of the 1 KB range being transferred:
7-11
Page 95
WSS 1000 Product Reference Guide
Memory Transfer Sending: XXXX
The display is updated for every 1024 bytes (1 KB) of memory. 4. When the transmission completes or aborts, the wrist computer displays the transmission status screen: Memory Transfer Status
0000
A status of 0000 (all zeros) indicates that the transfer was successful. Any other status indicates failure. Refer to Communication Status Codes on page 7-5 for communications status codes which indicate the source of the error.
End Communications To return to the Command Mode main menu, press <CLEAR>. Then take whatever corrective action is necessary, and reboot the wrist computer.
7-12
Page 96
Appendix A Specifications Environmental Considerations The WSS 1000’s operating conditions are listed in Table A-1. Table A-1. Operating Specifications Operating Temperature
-20° to 50°C (-4°F to 122°F)
Storage Temperature
-40° to 60°C (-40° to 140°F) The battery may be stored at -40° C for up to 72 hours.
Humidity
5% to 95% non-condensing
Moisture Infiltration Resistance
Complies with MIL-STD-810D, 506.2, Procedure II-Drip
Altitude
Operation: 0 to 10,000 feet Storage: Up to 50,000 for 24 hours; rates of change up to 4,000 feet per minute
Mechanical Shock
5-foot drop to concrete
A-1
Page 97
WSS 1000 Product Reference Guide
RS 1 Decode Zone Note: Typical performance at 68°F (20°C) on high quality symbols 10 25.4
12.7
0
0
5
12.7
Width of field
Scanner
5
7.5 Mil 15 Mil 20 Mil 40 Mil
10 25.4
55 Mil
0 0
2
8
4 6 12.7
10 12 25.4
14 16 18 20 22 38.1 50.8
24 26 In. 63.5 Cm.
In. Cm.
Depth of field as a function of minimum element width
WS 1200 Decode Zone Note: Typical performance at 68°F (20°C) on high quality symbols.
WS 1200
7.5
50.8
10
25.4
0
0 25.4 50.8
15 mil
30
76.2
43.2
109.7
39 44
40 mil
90
10 55 mil
100 70 mil reflective
60
20 50.8
40 60 101.6 152.4
180
100 mil reflective
66
240
80 203.2
100 2.54
120 304.8
Depth of Field
A-2
76.2
20
20
20 mil
0 0
30
10
7
In. cm cm 109.7
22
10 mil 9
In. 43.2
140 160 180 355.6 406.4 457.2
200 508
220 558.8
240 609.6
W i d t h o f F i e l d
Page 98
Appendix B WWC 1000 Keyboards Introduction The WWC 1000 wrist computer has a configurable 27-key keyboard. By combining keystrokes, the keyboard can emulate the full IBM-PC XT keyboard. This appendix provides the standard keyboard definitions and indicates how key codes are produced on the WWC 1000 wrist computer.
Keyboard Operation On a PC, each key generates a scan code. The character code generated by a given key is determined by the scan code and the current keyboard state: unshifted, shifted, control, function, left shift, or right shift. The scan code generated by each key is constant, independent of the keyboard state. The WWC 1000 keyboard emulates the full PC/XT keyboard using one or more modifier keys in sequence, followed by a character key. The modifier keys are: Function (FUNC) Shift Control (CTRL) Left Shift Right Shift The remaining keys (a through z, 0 through 9, special characters) are called “character keys.”
B-1
Page 99
WSS 1000 Product Reference Guide
The character generated is a function of the key scan code and the keyboard state, as on a PC. The main difference is that the scan code generated by a key is also variable, determined by the keyboard state.
Keyboard Diagrams The codes and characters generated by each modifier key or sequence are shown in the following figures.
4D
→
00
4B
←
00
48
∨
00
50
∨
00
00
P1
SHIFT CTRL CAPS LOCK
02
LEFT 69
FUNC
07
39
1
6
31
03
36
08
20
01
SPACE
2
7
32
04
37
09
1B
43
CLEAR
3
8
33
05
38
0A
00
3B
MENU
Scan Code (Hexadecimal)
4
9
34
06
39
0B
00
0E
HELP
5
0
1
31
Printable Character or Logical Key Sequence
Figure B-1. Unmodified Keyboard
B-2
30
08
BKSP
ASCII Value (Hexadecimal) 02
35
RIGHT 1C
0D
ENTER
Page 100
Keyboards
4D
→
00
4B
←
00
48
∨
00
50
∨
00
FUNC CAPS CTRL CAPS LOCK
1E
0C
2D
25
16
- a k u
61
2E
6B
32
75
11 c m w
63
12
6D
18
77
15 e o y
65
22
6F
10 g q
67
17
71
1F i s
53
79
LAMP
69
73
RIGHT 0F
09
TAB
00
DEL
Figure B-2. Left Unmodified Keyboard
4D
→
00
4B
←
00
48
∨
00
∨
00
50
2E
.
SHIFT NUM LOCK CAPS LOCK
30
LEFT 34
ALT STATE
26 b l
2F v
62
20
6C
31
76
2D d n x
64
21
6E
19
78
2C f p z
66
23
70
13
7A
52 h r
INS
68
24
72
14
00
0E j t
6A
74
08
BKSP
1C
0D
ENTER
Figure B-3. Right Unmodified Keyboard B-3