Switch Web UI Access and Image Upgrades 2.1 Accessing the Switch Web UI 2.1.1 Web UI Requirements The switch Web UI is accessed using Internet Explorer version 5.5 (or later) and SUN JRE (Java Runtime Environment) 1.5 (or later). Refer to the Sun Microsystems Web site for information on downloading JRE. NOTE
To successfully access the switch Web UI through a firewall, UDP port 161 must be open in order for the switch’s SNMP backend to function.
To prepare Internet Explorer to run the Web UI: 1. Open IE’s Tools > Internet Options panel and select the Advanced tab. 2. Uncheck the following checkboxes:
Page 46
2-2
Installing the System Iamge
•
Use HTTP 1.1
•
Java console enabled (requires restart)
•
Java logging enabled
•
JIT compiler for virtual enabled (requires restart).
2.1.2 Connecting to the Switch Web UI To display the Web UI, launch a Web browser on a computer with the capability of accessing the switch. NOTE
Ensure you have HTTP connectivity to the switch, as HTTP is a required to launch the switch Web UI from a browser.
To display the switch Web UI: 1. Point the browser to the IP address assigned to the wired Ethernet port (port 2). Specify a secure connection using the https:// protocol. The switch login screen displays:
Page 47
Switch Web UI Access and Image Upgrades
2-3
2. Enter the User ID admin, and Password superuser. Both are case-sensitive. Click the Login button. NOTE
If using HTTP to login into the switch, you may encounter a Warning screen if a self-signed certificate has not been created and implemented for the switch. This warning screen will continue to display on future login attempts until a self-signed certificate is implemented. Symbol recommends only using the default certificate for the first few login attempts until a self-signed certificate can be generated.
NOTE
If your password is lost, there is a means to access the switch, but you are forced to revert the switch back to its factory default settings and lose your existing configuration (unless saved to a secure location). Consequently, Symbol recommends keeping the password in a secure location so it can be retrieved. For information on password recovery, see Switch Password Recovery on page 2-3.
Once the Web UI is accessed, the Switch main menu item displays a configuration tab with high-level switch information. Click the Show Dashboard button to display an overall indicator of switch health. Once the switch is fully configured, the dashboard is the central display for the user to view the version of firmware running on the switch, quickly assess the last 5 alarms generated by the switch, view the status of the switch’s Ethernet connections and view switch CPU and memory utilization statistics. NOTE
The chapters within this System Reference Guide are arranged to be complimentary with the main menu items in the menu tree of the switch Web UI. Refer to this content to configure switch network addressing, security and diagnostics as required.
2.2 Switch Password Recovery If the switch Web UI password is lost, you cannot get passed the Web UI login screen for any viable switch configuration activity. Consequently, a password recovery login must be used that will default your switch back to its factory default configuration. To access the switch using a password recovery username and password:
!
CAUTION Using this recovery procedure erases the switch’s current configuration and data files from the switch /flash dir. Only the switch’s license keys are retained. You should be able to log in using the default username and password (admin/ superuser) and restore the switch’s previous configuration (only if it has been exported to a secure location before the password recovery procedure was invoked).
1. Point the browser to the IP address assigned to the wired Ethernet port (port 2). The switch login screen displays: 2. Enter a password recovery username of restore and password recovery password of restoreDefaultPassword. Click the Login button. The switch will login into the Web UI with its reverted default configuration. If you had exported the switch’s previous configuration to an external location, it now can be imported back to the switch. For information on importing switch configuration files, see Transferring a Config File on page 3-17.
Page 48
2-4
Installing the System Iamge
2.3 Upgrading the Switch Image The WS510 Series Switch ships with a factory installed firmware image with the full feature functionality described in this System Reference Guide. However, Symbol periodically releases switch firmware that includes enhancements or resolutions to known issues. Verify your current switch firmware version with the latest version available from the Symbol Web site before determining if your system requires an upgrade. Additionally, legacy users running either the 1.4.x or 2.x version switch firmware may want to upgrade to the new 3.0 baseline to take complete advantage of the new diverse feature set available to them. This chapter describes the method to upgrade from either the 1.4.x or 2.x baseline to the new 3.0 baseline.
! ! !
CAUTION Symbol recommends caution when upgrading your WS5100 switch image to the 3.0 baseline as portions of your configuration will be lost and unrecoverable. Ensure that you have exported your switch configuration to a secure location before upgrading your switch. The upgrade.log file will contain a list of issues found in the conversion of the configuration file to the new format. CAUTION If using a 1.4.x or 2.x admin user password shorter than 8 characters (such as the default symbol password), the password will be converted to the 3.0 baseline admin password of “password” upon a successful update to the 3.0 baseline. Ensure your existing 1.4.x or 2.x admin password is longer than 8 characters before updating, or leave as is and use “superuser” to login into an updated 3.0 baseline. CAUTION After upgrading the switch baseline from 1.4.x or 2.x to the 3.0 baseline, applet caching can produce unpredictable results and contents. After the upgrade, ensure your browser is restarted. Otherwise, the credibility of the upgrade can come into question.
2.3.1 Upgrading the Switch Image from 1.4.x or 2.x to Version 3.0 To upgrade a switch running either a 1.4.x or 2.x version to the latest 3.0 version switch firmware: 1. Execute the PreUpgradeScript utility (or use the CLI) to ensure there is enough space on your system to perform the upgrade. The PreUpgradeScript utility should be in the same directory as the upgrade files. 2. Install the Cfgupgrade1.x-setup utility on a Windows desktop system by double clicking the Cfgupgrade 1.x-setup file. Follow the prompts displayed by the installer to install Cfgupgrade 1.x-setup. A WS5100 Configuration Upgrade icon gets created within the Program Files folder. The icon can be optionally created on your Windows desktop as well. 3. From the WS5100 running either 1.4.x or 2.x, create a configuration and save it on the switch. WS5100# save
<file name> <.cfg>
This is the configuration that will be upgraded to the new 3.0 baseline. NOTE
Symbol recommends saving a copy of the switch configurartion to a secure location before the upgrade. If an error occurs with the upgrade a viable configuration will be needed to restore on the switch.
Page 49
Switch Web UI Access and Image Upgrades
2-5
4. Copy the configuration file <.cfg> from the legacy WS5100 to the Windows system where the conversion utility resides. Use ftp or tftp to transfer the file. 5. Click on the WS5100 configuration Upgrade icon (from the Windows system). 6. Select the config file copied on to the windows system and run it. A folder having the same name as the config file is created. The folder contains the converted startupconfig file (in the new upgraded format) along with other log files. 7. Copy the startup-config file back to the WS5100 running using either tftp or ftp. 8. Download or copy the image file <WS5100-3.0.0.0-XX.v1> or <WS5100-3.0.0.0-XX.v2> to the WS5100 running the legacy switch firmware. NOTE
If upgrading a 1.4.x version WS5100 to the new 3.0 baseline, be sure you are using the <WS5100-3.0.0.0-XX.v1> image file. If upgrading a 2.x version WS5100 to the new 3.0 baseline, be sure you are using the <WS5100-3.0.0.0-XX.v2> image file.
9. On the WS5100, type: WS5100#service WS5100#password "password" exec Upon reboot, the switch runs the 3.0 image using startup-config as the running configuration. 10. Repeat the instructions above for additional switch upgrades, ensuring <WS5100-3.0.0.0-XX.v1> is used for 1.4.x version upgrades, and <WS5100-3.0.0.0-XX.v2> is used for 2.x version upgrades.
2.4 Downgrading the Switch Image from Version 3.0 to 1.4.x or 2.x If for some reason you want to downgrade your WS5100 back down to a 1.4.x or 2.x version firmware image, use one of the two following image files: •
WS5100-1.4.3.0-012R.img
•
WS5100-2.1.0.0-029R.img
Page 50
2-6
Installing the System Iamge
2.5 AP-4131 Access Point to Access Port Conversion To convert an AP-4131 “fat” access point to a “thin” AP-4131 access port you need to load the port conversion version firmware. Refer to the files available with you Symbol Web site download package. To convert an AP-4131 access point 1. Verify a TFTP server is up and running and the firmware you are going to install is in the root directory of the TFTP server. 2. Log in to the AP-4131 as Admin. The default password is Symbol.
3.
Select the AP Installation main menu item.
4.
From the IP Address field, enter a new IP address (if required) and select Save-[F1] to save the change. If the IP address was changed, you will need to reset the AP for the change to be implemented.
5. Reset the AP if you changed the AP's IP address, buy displaying the System Summary and selecting the Reset AP option. If you reset the AP-4131 you will need to login as Admin again.
Page 51
Switch Web UI Access and Image Upgrades
2-7
6. Select the Special Functions main menu item. 7. Select the Firmware Update Menu-[F3] menu item 8. Select the Alter Filename(s)/HELP URL/TFTP Server menu item. a. Confirm that the Firmware File Name is correct, make changes as needed. b. Enter the IP address of your TFTP server, select enter. c.
Select F1 to save your changes.
9. Select Firmware under the Use TFTP to update Access Point's option.
10. Select yes when asked to confirm. 11. The AP-4131 will now reset, download and install the desired firmware. 12. Once the firmware download is complete, connect the AP-4131 to the PoE switch and WS5100. The AP-4131 should adopt and operate as a “thin” access port.
Page 52
2-8
Installing the System Iamge