Page 446
10-28
Syslog
10.16.8 Severity 7 Messages There are no severity 7 messages for NSM.
10.17 Panic Messages Panic message is used to indicate that a switch restart was due to a kernel crash. All messages are classified based on the severity of the messages.
10.17.1 Severity 0 Messages There are no severity 0 messages for Panic.
10.17.2 Severity 1 Messages There are no severity 1 messages for Panic.
10.17.3 Severity 2 Messages There are no severity 2 messages for Panic.
10.17.4 Severity 3 Messages There are no severity 3 messages for Panic.
10.17.5 Severity 4 Messages There are no severity 4 messages for Panic.
10.17.6 Severity 5 Messages These messages are with severity 5 and indicate a normal but significant condition. Table 10.37 lists the severity 5 messages for Panic. Table 10.37 List of Severity 5 Messages for Panic Mnemonic
PANIC
Description
Last reboot was caused by a panic
10.17.7 Severity 6 Messages There are no severity 6 messages for Panic.
Page 447
Syslog
10-29
10.17.8 Severity 7 Messages There are no severity 7messages for Panic.
10.18 Process Management Daemon This chapter provides information on messages that are for the Process Management Daemon (PMD). The Process Management Daemon takes care of handling all process that are running on the device. Processes must be managed without causing major impact on the overall system behavior. The PMD takes care of starting, stopping, and restarting processes on the device. These messages indicate the different states of a process and issues relating to their states. All messages are classified based on the severity of the messages.
10.18.1 Severity 0 Messages These messages are with severity 0 and are for emergency condition. It indicates the system has become unstable and action must be taken immediately. Table 10.38 lists the severity 0 messages for Process Management Daemon. Table 10.38 List of Severity 0 Messages for Process Management Daemon Mnemonic
PROCSYSRSTRT
Description
Process "[str]" reached its maximum number of allowed restarts. Rebooting the system
10.18.2 Severity 1 Messages These messages are with severity 1 and action need to be taken on these messages immediately. Table 10.39 lists the severity 1 messages for Process Management Daemon. Table 10.39 List of Severity 1 Messages for Process Management Daemon Mnemonic
PROCMAXRSTRT
Description
Process "[str]" reached its maximum number of allowed restarts
10.18.3 Severity 2 Messages There are no severity 2 messages for Process Management Daemon.
Page 448
10-30
Syslog
10.18.4 Severity 3 Messages These messages are with severity 3 and indicate an error condition. Table 10.40lists the severity 3 messages for Process Management Daemon. Table 10.40 List of Severity 3 Messages for Process Management Daemon Mnemonic
PROCRSTRT
Description
Process "[str]" is not responding. Restarting process
10.18.5 Severity 4 Messages These messages are with severity 4 and are a warning that an issue has occurred. Table 10.41 lists the severity 4 messages for Process Management Daemon. Table 10.41 List of Severity 4 Messages for Process Management Daemon Mnemonic
PROCNORESP
Description
Process "[str]" is not responding
10.18.6 Severity 5 Messages These messages are with severity 5 and indicate a normal but significant condition. Table 10.42lists the severity 5 messages for Process Management Daemon. Table 10.42 List of Severity 5 Messages for Process Management Daemon Mnemonic
Description
PROCSTOP
Process "[str]" has been stopped
PROCID
Process "[str]" changed its PID from [int] to [int]
STARTUPCOMPLETE
System startup complete
10.18.7 Severity 6 Messages These messages are with severity 6 and are for information only. Table 10.43 lists the severity 6 messages for Process Management Daemon. Table 10.43 List of Severity 6 Messages for Process Management Daemon Mnemonic
PROCSTART
Description
Starting process "[str]"
10.18.8 Severity 7 Messages There are no severity 7 messages for Process Management Daemon.
Page 449
Syslog
10-31
10.19 WCCPD (Redundancy) Message This chapter provides information on messages that are for the Wireless Cluster Control Protocol Daemon (WCCPD) (Redundancy). The WCCP provides facility to minimize service interruption when a switch fails and when another switch takes its place to adopt the access ports of the failed switch. These messages are specific to the WCCP Daemon and provide information on the state of the failover mechanism. All messages are classified based on the severity of the messages.
10.19.1 Severity 0 Messages There are no severity 0 messages for WCCPD (Redundancy).
10.19.2 Severity 1 Messages These messages are with severity 1 and action need to be taken on these messages immediately. Table 10.44 lists the severity 1 messages for WCCPD (Redundancy). Table 10.44 List of Severity 1 Messages for WCCPD (Redundancy) Mnemonic
Description
PEERACTIVEINVLCONF
Peer [ip], with group ID [uint] in active mode has detected with invalid configuration
PEERSTAINVLCONF
Peer [ip], with group ID [uint] in standby mode has detected with invalid configuration
AUTHORIZATIONCHNGD
Redundancy group authorization level changed to [uint]
10.19.3 Severity 2 Messages There are no severity 2 messages for WCCPD (Redundancy).
10.19.4 Severity 3 Messages There are no severity 3 messages for WCCPD (Redundancy).
10.19.5 Severity 4 Messages These messages are with severity 4 and are a warning that an issue has occurred. Table 10.45 lists the severity 4 messages for WCCPD (Redundancy). Table 10.45 List of Severity 4 Messages for WCCPD (Redundancy) Mnemonic
Description
PEERACTIVEDOWN
Peer [ip], with group ID [uint] in active mode is down
PEERSTADOWN
Peer [ip], with group ID [uint] in standby mode is down
Page 450
10-32
Syslog
Table 10.45 List of Severity 4 Messages for WCCPD (Redundancy) Mnemonic
ADOPTEXCEED
Description
Total APs adoption exceeded redundancy group authorization level in group [uint], adoption count: [uint], group authorization level: [uint]
10.19.6 Severity 5 Messages These messages are with severity 5 and indicate a normal but significant condition. Table 10.46lists the severity 5 messages for WCCPD (Redundancy). Table 10.46 List of Severity 5 Messages for WCCPD (Redundancy) Mnemonic
Description
PEERACTIVEUP
Heartbeats getting exchanged with peer [ip], group ID [uint] in active ode
PEERSTAUP
Heartbeats getting exchanged with peer [ip], group ID [uint] in standby mode
PEERACTIVEOPER
Peer [ip], with group ID [uint] in active mode is fully operational
PEERSTAOPER
Peer [ip], with group ID [uint] in standby mode is fully operational
REDUNDANCYDISABLED
Redundancy protocol disabled
REDUNDANCYENABLED
Redundancy protocol enabled
10.19.7 Severity 6 Messages These messages are with severity 6 and are for information only. Table 10.47 lists the severity 6 messages for WCCPD (Redundancy). Table 10.47 List of Severity 6 Messages for WCCPD (Redundancy) Mnemonic
Description
STATEDISABLED
The wireless module has changed its redundancy state to disabled
STATESTARTUP
The wireless module has changed its redundancy state to startup
STATEDISCOVERY
The wireless module has started discovering other members in the redundancy group
STATEONLINE
The wireless module has started adopting radio ports actively
10.19.8 Severity 7 Messages There are no severity 7 messages for WCCPD (Redundancy).
Page 451
Syslog
10-33
10.20 Test Module Messages This chapter provides information on messages that are for the Test Module. All messages are classified based on the severity of the messages.
10.20.1 Severity 0 Messages These messages are with severity 0 and are for emergency condition. It indicates the system has become unstable and action must be taken immediately. Table 10.48 lists the severity 0 messages for Test Module. Table 10.48 List of Severity 0 Messages for Test Module Mnemonic
TESTEMERG
Description
Emergency test message
10.20.2 Severity 1 Messages These messages are with severity 1 and action need to be taken on these messages immediately. Table 10.49 lists the severity 1 messages for Test Module. Table 10.49 List of Severity 1 Messages for Test Module Mnemonic
TESTALERT
Description
Alert test message
10.20.3 Severity 2 Messages These messages are with severity 2 and indicate a critical condition. Table 10.50 lists the severity 2 messages for Test Module. Table 10.50 List of Severity 2 Messages for Test Module Mnemonic
TESTCRIT
Description
Critical test message
10.20.4 Severity 3 Messages These messages are with severity 3 and indicate an error condition. Table 10.51lists the severity 3 messages for Test Module. Table 10.51 List of Severity 3 Messages for Test Module Mnemonic
TESTERR
Description
Error test message
Page 452
10-34
Syslog
10.20.5 Severity 4 Messages These messages are with severity 4 and are a warning that an issue has occurred. Table 10.52 lists the severity 4 messages for Test Module. Table 10.52 List of Severity 4 Messages for Test Module Mnemonic
TESTWARN
Description
Warning test message
10.20.6 Severity 5 Messages These messages are with severity 5 and indicate a normal but significant condition. Table 10.53lists the severity 5 messages for Test Module. Table 10.53 List of Severity 5 Messages for Test Module Mnemonic
TESTNOTICE
Description
Notice test message
10.20.7 Severity 6 Messages These messages are with severity 6 and are for information only. Table 10.54 lists the severity 6 messages for Test Module. Table 10.54 List of Severity 6 Messages for Test Module Mnemonic
TESTINFO
Description
Informational test message
10.20.8 Severity 7 Messages These messages are with severity 7 and are for debug purposes only. Table 10.55 lists the severity 7 messages for Test Module Table 10.55 List of Severity 6 Messages for Test Module Mnemonic
Description
TESTDEBUG
Debug test message
TESTARGS
Integer: [int], Unsigned Integer: [uint], String: [str], Hex: [hex2] [hex4] [hex8], IP: [ip], MAC: [mac], Decimal: [dec2]
Page 453
Syslog
10-35
10.21 Update Server Messages This chapter provides information on messages that are for the Update Server. All messages are classified based on the severity of the messages.
10.21.1 Severity 0 Messages There are no severity 0 messages for Update Server
10.21.2 Severity 1 Messages These messages are with severity 1 and action need to be taken on these messages immediately. Table 10.56 lists the severity 1 messages for Update Server. Table 10.56 List of Severity 1 Messages for Update Server Mnemonic
Description
CFGINSTFAIL
Failed downloading configuration file - running with factory default configuration
INSTCSUM
Configuration file on server [ip] has a wrong MD5 checksum running with factory default configuration
IMGINSTFAIL
Auto-install of image [str] failed
IMGINSTSTALL
Auto-install of image [str] stalled
INSTIFDOWN
Management interface [str] is down - can not start auto-install
INSTBADIP
Update server's IP address [ip] is invalid - can not start auto-install
INSTUNREACH
Update server is unreachable - can not start auto-install
INSTBADPATH
Image location on the update server is invalid - can not start autoinstall
10.21.3 Severity 2 Messages There are no severity 2 messages for Update Server.
10.21.4 Severity 3 Messages These messages are with severity 3 and indicate an error condition. Table 10.57lists the severity 3 messages for Update Server. Table 10.57 List of Severity 3 Messages for Update Server Mnemonic
SAVECONFIG
Description
Could not save upd-server configuration on chassis. Communication failure between WLAN module and chassis
Page 454
10-36
Syslog
10.21.5 Severity 4 Messages There are no several 4 messages for Update Server.
10.21.6 Severity 5 Messages These messages are with severity 5 and indicate a normal but significant condition. Table 10.58 lists the severity 5 messages for Update Server. Table 10.58 List of Severity 5 Messages for Update Server Mnemonic
Description
ESPDELCKSUM
Deleting startup configuration. Local configuration checksum =\"[str]\", does not match chassis checksum = \"[str]\"
ESPDELCONFUPD
Deleting startup configuration. Initiating configuration update
ESPDELIMGUPD
Deleting startup configuration. Initiating image update
ESPDELCONFIG
Deleting startup configuration. Received empty chassis configuration. Going to factory default
INSTLREQ
Local img ver = \"[str]\" does not match expected image version = \"[str]\". Auto-install required
ESPDLOADFAIL
Update server unreachable, IP address = [ip], configuration file download failed
ESPFILECKSUMMISM
Update server unreachable, IP address = [ip], upd-server has the wrong configuration file
ESPIMGUPDFAIL
Update server unreachable, IP address = [ip], image update failed
ESPIMGUPDSTALL
Update server unreachable, IP address = [ip], image update stalled
ESPSNMPSET
Update server unreachable, IP address = [ip], set by SNMP user
CFGEMPTY
Configuration received from chassis is empty
IMGINSTOK
Image [str] was installed successfully
CFGINSTOK
Configuration was installed successfully
10.21.7 Severity 6 Messages There are no severity 6 messages for Update Server.
10.21.8 Severity 7 Messages There are no several 7 messages for Update Server.