The text of a manual · part 5 of 51
WS5100 Series Switch System Reference Guide: Chapter 1 - Overview, pages 28 to 36
Pages 28 to 36 of 458, from WS5100 Series Switch System Reference Guide
The original document is the PDF (9.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol WS-5100
Page 28
1-10
Overview
1.2.2.6 Voice Prioritization The WS5100 has the capability of having its QoS policy configured to prioritize network traffic requirements for associated MUs. Use QoS to enable voice prioritization for devices using voice as its transmission priority. Voice prioritization allows you to assign priority to voice traffic over data traffic, and (if necessary) assign legacy voice supported devices (non WMM supported voice devices) additional priority. Currently voice support implies the following: • • •
Spectralink voice prioritization - Spectralink sends packets that allow the switch to identify these MU's as voice MU's. Thereafter, any UDP packet sent by these MU's is prioritized ahead of data. Strict priority - The prioritization is strict. Multicast prioritization - Multicast frames that match a configured multicast mask bypass the PSP queue. This features permits intercom mode operation without delay (even in the presence of PSP MU's).
1.2.2.7 Self Healing Self Healing is the ability to dynamically adjust the RF network by modifying transmit power and/or supported rates, based on an AP failure. In a typical RF network deployment, the APs are configured for Transmit Power below its maximum level. This allows the Tx Power to be increased when there is a need to increase coverage whenever an AP fails. When an AP fails, the Tx Power/Supported rates of APs neighboring the failed AP is adjusted. The Tx power is increased and/or Supported rates are decreased. When the failed AP becomes operational again, the Neighbor AP’s Tx Power/Supported rates are brought back to the levels in operation before the self healing operation changed them. The switch detects an AP failure when: • •
AP stops sending heartbeats. AP beacons are no longer being sent.
Configure 0 (Zero) or more APs to act as either: • • •
Detector APs, Detector APs scan all channels and send beacons to the switch which uses the information for self-healing. Neighbor APs, When an AP fails, neighbor APs assist in self healing. Self Healing Actions, When an AP fails, actions are taken on the neighbor APs to do self-healing.
Detector APs
Configure an AP in either – Data mode (the regular mode) or Detector mode. In Detector mode, the AP scans all channels at a configurable rate and forwards received beacons to the WS5100. The WS5100 uses the received information to establish a receive signal strength baseline over a period of time and initiates self-healing procedures (if necessary). Neighbor Configuration
Neighbor detect is a mechanism allowing an AP to detect its neighbors and their signal strength. This enables you to verify your installation and configure it for self-healing when an AP fails.
Page 29
Overview
1-11
Self Healing Actions
This mechanism allows you to assign a self healing action to an AP's neighbors, on a per-AP basis. If AP1 detects AP2 and AP3 as its neighbors, you can assign failure actions to AP2 and AP3 whenever AP1 fails. You can assign four self healing actions: • • • •
No action Decrease supported rates Increase Tx power Both 2 and 3.
You can also specify the Detector AP (AP2 or AP3) to stop detecting and adopt the RF settings of the failed AP.
1.2.2.8 Port/Switch Protocols WS5100 supports the following two access-port/switch protocols: • •
WISP WISPe (WISP extended)
This dual support is also available for older platforms that supports legacy access ports. Newer platforms using an AP300 (or newer) access port only support WISPe. WISP
WISP is a legacy, layer 2 port/switch protocol used with all legacy platforms. It is available on the AP100, AP200, AP300 and a variety of access point conversions. WISPe
WISPe is an extension of the original WISP protocol supporting layer 3 access-port/switch traffic and wireless bridging between access ports. WISPe is only available on the AP300 (or newer) access port. WISP/WISPe Upgrade/Downgrade
The conversion of access ports from WISP to WISPe (and vice-versa) is transparent. AP300 access ports running WISP firmware can be adopted by a switch that only supports WISPe. When a WISP access port seeks adoption, the WISPe switch recognize it and sends firmware to it to convert it into a WISPe access port. Conversely, a WISPe access port (if deployed in an environment with WISP switches) discovers and adopts it to a WISP switch. Access Port Support
Access ports vary by platform. Access port and access point conversion support is summarized in the following table: AP types
WS 5000 3.0
AP300
WISPe
AP100
WISP
AP4131
WISP
AP200
Not Supported
AP4121
Not Supported
Page 30
1-12
Overview
AP types
WS 5000 3.0
All other Access Point conversions
Not Supported
CAPWAP Compatibility
CAPWAP is a proposed standard for port/switch protocols. It is intended that WISPe be similar to CAPWAP. When the CAPWAP protocol is standardized, it is relatively easy to adapt the switch software so CAPWAP based 3rd party access points can be adopted.
1.2.2.9 Wireless Capacity Wireless capacity specifies the maximum numbers of MUs, access ports and wireless networks usable by a given switch. Wireless capacity is largely independent of performance. Aggregate switch performance is divided among the switch clients (MUs and access ports) to find the performance experienced by a given user. Each switch platform is targeted at specific market segments, so the capacity of each platform is chosen appropriately. Wireless switch capacity is measured by: • • • •
Maximum number of WLANs per switch Maximum number of access ports per Switch Maximum number of MUs per switch Maximum number of MUs per access port.
Up to 48 access ports are supported by the switch. The actual number of access ports adoptable by a switch is defined on a per platform basis and will typically be lower than 48.
1.2.2.10 AP and MU Load Balancing Fine tune a network to evenly distribute the data and/or processing across available resources. The following 2 topics explain load balancing: • •
MU Balancing Across Multiple APs AP Balancing Across Multiple Switches
MU Balancing Across Multiple APs
As per the 802.11 standard, AP and MU association is a process conducted independently of the switch. 802.11 provides message elements used by the MU firmware to influence the roaming decision. The switch implements the following MU load balancing techniques: • •
802.11e admission control, 1 byte: channel utilization % and 1 byte: MU count is sent in QBSS Load Element in beacons to MU. Symbol load balancing element (proprietary), 2 byte: Kbps, 2 byte : Kbps and 2 byte : MU Count are sent in beacon to MU. NOTE
Each switch can support a maximum of 4096 MUs.
Page 31
Overview
1-13
AP Balancing Across Multiple Switches
At adoption time, the AP solicits and receives multiple adoption responses from the switches on the network. These adoption responses contain preference and loading information the AP uses to select the optimum switch to be adopted by. Use this mechanism to define which APs are adopted by which switches. By default, the adoption algorithm generally distributes AP adoption evenly among the switches available. NOTE
Each switch can support a maximum of 48 access ports. However, port adoption per switch is determined by the number of licenses acquired.
1.2.2.11 Wireless Roaming The following types of wireless roaming are supported by WS5100: • • • • • •
L3 Roaming Fast Roaming Interswitch Layer 2 Roaming International Roaming MU Move Command Virtual AP
L3 Roaming
L3 roaming works with switches in the mobility domain to exchange mobility related control information. This includes IP addresses, Media Access Control (MAC) address information and the HS-VLAN-id of all MUs in the mobility-domain. A consistent peer configuration results in full-mesh sessions required for L3 roaming to work correctly. Peering sessions use Transmission Control Protocol (TCP) as the transport layer protocol to carry mobility update messages. TCP provides the following advantages: • • •
TCP retransmits lost messages thereby providing reliable connectivity TCP ensures ordered message delivery using sequenced numbers. TCP has a built-in “keep-alive” mechanism which helps detect loss of connectivity to the peer or peer failure.
Fast Roaming
MUs roam from AP to AP as an MU moves throughout a WLAN coverage area. To improve roaming performance, various fast roaming features are implemented: • • • •
Pairwise Master Key (PMK) Caching, Caching credentials are in the AP, so the MU does not need to re- authenticate. PMK Opportunistic Caching, The MU starts transmitting on another AP in order for both AP's to connect to a common wireless switch. Switch to Switch Hand-Off, When an MU roams from a wireless switch in one subnet to a wireless switch in another subnet, the transport layer connections will be preserved as far as possible. PMK Pre-Authentication, The MU authenticates itself with the AP before roaming to it.
Interswitch Layer 2 Roaming
An associated MU (connected to a particular wireless switch) can roam to another access port connected to a different wireless switch. Both switches must be on the same L2 domain. Authentication information is not
Page 32
1-14
Overview shared between the switches, nor is buffered packets on one switch transferred to the other switch. Preauthentication between the switch and MU allows faster roaming. International Roaming
The wireless switch supports international roaming as per the 802.11d specification. MU Move Command
As a value added proprietary feature between Symbol infrastructure products and Symbol MUs, a move command has been introduced. This command permits an MU to roam between ports connected to the same wireless switch without the need to perform the full association and authentication defined by the 802.11 standard. The move command is a simple packet up/packet back exchange with the access port. Verification of this feature is dependent on its implementation in one or more mobile units. Virtual AP
The WS5100 supports multiple Basic Service Set Identifiers (BSSIDs). An access port capable of supporting multiple BSSID's generates multiple beacons, one per BSSID. Hence, an AP that supports 4 BSSID's can send 4 beacons. The basic requirement for supporting multiple BSSID's is multiple MAC addresses, since each BSSID is defined by its MAC address. When multiple BSSID's are enabled, you cannot tell by snooping the air whether any pair of beacons is sent out by the same physical AP or different physical AP. Hence the term "virtual AP's"- each virtual AP behaves exactly like a single-BSSID AP. Each BSSID supports 1 Extended Service Set Identifier (ESSID). Sixteen ESSIDs per switch are supported.
1.2.2.12 Power Save Polling An MU uses Power Save Polling (PSP) to reduce power consumption. When an MU is in PSP mode, the switch buffers its packets and delivers them using the DTIM interval. The PSP-Poll packet polls the AP for buffered packets. The PSP null data frame is used by the MU to signal the current PSP state to the AP.
1.2.2.13 QoS QoS provides the user a data traffic prioritization scheme. A QoS configuration scheme is useful in the case of congestion from excessive traffic or different data rates and link speeds. If there is enough bandwidth for all users and applications (unlikely because excessive bandwidth comes at a very high cost), then applying QoS has very little value. QoS provides policy enforcement for mission-critical applications and/or users that have critical bandwidth requirements when the switch’s total bandwidth is shared by different users and applications. The objective of QoS is to ensure each WLAN configured on the switch receives a fair share of the overall bandwidth, either equally or as per the proportion configured. Packets directed towards MUs are classified into categories such as Management, Voice and Data. Packets within each category are processed based on the weights defined for each WLAN. The WS5100 supports the following different QoS types: 802.11e QoS
802.11e enables real-time audio and video streams to be assigned a higher priority over regular data. The WS5100 supports the following 802.11e features: •
Basic WMM
Page 33
Overview
• • • • • • •
1-15
WMM Linked to 802.1p Priorities WMM Linked to DSCP Priorities Fully Configurable WMM Admission Control Unscheduled-APSD TSPEC Negotiation Block ACKQBSS Beacon Element
802.1p support
802.1p is a standard for providing QoS in 802-based networks. 802.1p uses three bits to allow switches to reorder packets based on priority level. 802.1p uses the Generic Attributes Registration Protocol (GARP) and the GARP VLAN Registration Protocol (GVRP). GARP allows MUs to request membership within a multicast domain, and GVRP lets them register to a VLAN. Voice QoS
When switch resources are shared between a Voice over IP (VoIP) conversation and a file transfer, bandwidth is normally exploited by the file transfer, thus reducing the quality of the conversation or even causing it to disconnect. With QoS, the VoIP conversation (a real-time session), receives priority, maintaining a high level of voice quality. The voice QoS used by the WS5100 ensures: • • • •
Strict Priority Spectralink Prioritization VOIP Prioritization (IP ToS Field) Multicast Prioritization
Data QoS
The WS5100 ensures the following for Data QoS: • •
Egress Prioritization by WLAN Egress Prioritization by ACL
DCSCP to AC Mapping
The WS5100 provides for the arbitrary mapping between Differentiated Services Code Point (DCSCP) values and WMM Access Categories. This mapping can be set manually.
1.2.2.14 Wireless Layer 2 Switching The WS5100 supports the following layer 2 wireless switching techniques: • • •
WLAN to VLAN MU User to VLAN WLAN to GRE
1.2.2.15 Automatic Channel Selection Automatic channel selection works as follows: 1. When a new AP is adopted, it scans each channel. However, the switch does not forward traffic at this time.
Page 34
1-16
Overview
2. The switch then selects the least crowded channel based on the noise and traffic detected on each channel. 3. The algorithm used is a simplified maximum entropy algorithm for each radio, where the signal strength from adjoining AP's/MU's associated to adjoining AP's is minimized. 4. The algorithm ensures adjoining AP's are as far away from each other as possible in terms of channel assignment. NOTE
Individual radios can be configured to perform automatic channel selection.
1.2.2.16 WMM-Unscheduled APSD This feature is also known as WMM Power Save or WMM-UPSD (Unscheduled Power Save Delivery). WMMUPSD defines an unscheduled service period, which are contiguous periods of time during which the switch is expected to be awake. If the switch establishes a downlink flow and specifies UPSD power management, then it requests and the AP delivers buffered frames associated with that flow during an unscheduled service period. The switch initiates an unscheduled service period by transmitting a trigger frame, where a trigger frame is defined as a data frame (e.g. an uplink voice frame) associated with an uplink flow having UPSD enabled. After the AP acknowledges the trigger frame, it transmits the frames in its UPSD power save buffer addressed to the triggering switch. UPSD is well suited to support bi-directional frame exchanges between a voice STA and its AP
1.2.3 Wired Switching The switch includes the following wired switching features: • • • • • •
DHCP Servers DDNS GRE Tunneling VLAN Enhancements Interface Management Multiple WLAN Support
1.2.3.1 DHCP Servers Dynamic Host Configuration Protocol (DHCP) allows hosts on an IP network to request and be assigned IP addresses, and discover information about the network to which they are attached. Configure address pools for each subnet, and whenever a DHCP client in that subnet requests an IP address, the DHCP server assigns an IP address from the address pool configured for that subnet. When a DHCP server allocates an address for a DHCP client, the client is assigned a lease, which expires after an pre-determined interval. Before a lease expires, clients (to which leases are assigned) are expected to renew them to continue to use the addresses. Once the lease expires, the client is no longer permitted to use the leased IP address.
1.2.3.2 DDNS Dynamic DNS is a method of keeping a domain name linked to a changing IP address. Typically, when a user connects to a network, the user’s ISP assigns it an unused IP address from a pool of IP addresses. This address is only valid for a short period. Dynamically assigning IP addresses increases the pool of assignable IP
Page 35
Overview
1-17 addresses. DNS maintains a database to map a given name to an IP address used for communication on the Internet. The dynamic assignment of IP addresses makes it necessary to update the DNS database to reflect the current IP address for a given name. Dynamic DNS updates the DNS database to reflect the correct mapping of a given name to an IP address.
1.2.3.3 GRE Tunneling GRE tunnelling extends a WLAN across a Layer 3 network using standards based GRE tunneling technology. • • •
•
GRE tunnels need to be explicitly provisioned on the switch as well as the tunnel termination device present at the other end of the Layer 3 network. One or more WLANS on the switch are then mapped to the GRE tunnel interface. The configuration is very similar to mapping WLANs to VLANs. All IP packets received from MUs on the WLAN are encapsulated in GRE and sent across the Layer 3 network. The tunnel termination device at the other end decapsulates the GRE header and routes the inner IP packet to its original destination. When packets are received on the GRE tunnel interface by the switch, the switch decapsulates the GRE header and forwards the IP packet to the MU based on the destination IP address. The MAC address of the MU is obtained from the MU table.
1.2.3.4 VLAN Enhancements The WS5100 has incorporated the following VLAN enhancements: • • • •
Physical port (L2) is now operated in Trunk Mode or Access Mode. VLAN now allows an AP to receive and send only untagged packets. All tagged packets received by the AP are discarded. The untagged traffic received is internally placed in an “access vlan”. A trunk port can now receive, both tagged and untagged packets. Only one native VLAN per trunk port is supported. All untagged traffic received on is placed into a “native vlan”. You can now configure a set of allowed VLANS on a trunk port. Packets received on this port that belong to other VLANs are discarded.
1.2.3.5 Interface Management The WS5100 permits a physical interface to Auto Negotiate, Full Duplex or Half Duplex. The WS5100 also allows: • •
Manual bandwidth configuration of a physical interface to 10/100/1000Mbps. This is only permitted if duplex is not set to Auto-Negotiate. Manual configuration of administrative shutdown of a physical interface.
1.2.3.6 Multiple WLAN Support The WS5100 supports 32 WLANS.
1.2.4 Management Features The WS5100 Series Switch includes the following management features: • •
Secure browser-based management console Command Line Interface (CLI) accessible via the serial port or through a Secure Shell (SSH) application
Page 36
1-18
Overview
•
CLI Service mode enables the capture of system status information that can be sent to Symbol personnel for use in problem resolution Support for Simple Network Management Protocol (SNMP) version 3 as well as SNMP version 2 TFTP upload and download of access port firmware and configuration files Graphing of wireless statistics Dashboard summary of system state in the Web UI Multi switch management via MSP application Heat Map support for RF deployment Secure Guest Access Switch Discovery enabling users to discover each Symbol switch on the specified network.
• • • • • • • •
1.2.5 Security Features WS5100 switch security can be classified into wireless security and wired security A WS5100 Series Switch includes the following Wireless Security features: • • • • • • • • • •
Encryption and Authentication MU Authentication Secure Beacon MU to MU Allow MU to MU Disallow Switch - to - Wired 802.1x Authentication IEEE 802.1AB LLDP WIDS Rogue AP Detection
The switch includes the following wired security features: • • • • •
ACLs Local Radius Server IPSec VPN NAT Certificate Management
1.2.5.1 Encryption and Authentication The switch can implement the following encryption and authentication types: • • • •
WEP WPA WPA2 Keyguard-WEP
WEP
Wired Equivalent Privacy (WEP) is an encryption scheme used to secure wireless networks. WEP was intended to provide comparable confidentiality to a traditional wired network, hence the name. WEP had many serious