WS5100 Series Switch System Reference Guide: Chapter 7 - Switch Management, pages 315 to 322
Pages 315 to 322 of 458, from WS5100 Series Switch System Reference Guide
The original document is the PDF (9.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol WS-5100
Page 315
Switch Management This chapter describes the Management Access main menu items used to configure the switch. This chapter contains following content: • • • • • •
Displaying the Management Access Interface Configuring Access Control Configuring SNMP Access Configuring SNMP Traps Configuring SNMP Trap Receivers Configuring Management Users NOTE
HTTPS must be enabled to access the switch applet. Ensure that HTTPS access has been enabled before using the login screen to access the switch applet.
Page 316
7-2
Switch Management
7.1 Displaying the Management Access Interface Refer to the main Management Access interface for a high-level overview of the current switch firmware version and the current switch log output configuration. Use this information to discern whether a switch firmware upgrade is required (by checking the Symbol Website for a newer version) of if the switch is outputting log data appropriately. NOTE
When the switch’s configuration is successfully updated (using the Web UI), the effected screen is closed without informing the user their change was successful. However, if an error were to occur, the error displays within the effected screen’s Status field and the screen remains displayed. In the case of file transfer operations, the transfer screen remains open during the transfer operation and remains open upon completion (with status displayed within the Status field).
To display the main Management screen: 1. Select Management Access from the main menu tree.
2. Refer to the Current Status field to review the following read-only information: Firmware In Use
The Firmware In Use value displays the software version currently running on the switch.
Log Output
The Log Output value displays the target location for log files output by the switch.
NOTE
The Apply and Revert functions are greyed out within this screen, as this screen is read-only with no configurable parameters for the user to update and save.
Page 317
Switch Management
7-3
7.2 Configuring Access Control Refer to the Access Control screen to enable (or disable) the various access mechanisms available to the switch. To configure access control settings on the switch: 1. Select Management Access > Access Control from the main menu tree.
2. Refer to the Management Settings field to enable or disable the following switch interfaces: Enable Telnet
Select this checkbox to allow the switch to use telnet session access for communicating over the network. This setting is enabled by default.
Port
Define the port number used for the Telnet session with the switch.
Enable SNMP v2
Select this checkbox to enable SNMPv2 access to the switch and configuration activities over the SNMPv2 interface. This setting is enabled by default.
Enable SNMP v3
Select this checkbox to enable SNMPv3 access to the switch and configuration activities over the SNMPv3 interface. This setting is enabled by default.
Enable HTTP
Select this checkbox to enable HTTP access to the switch. The Hypertext Transfer Protocol (HTTP) is an application-level protocol for distributed, collaborative, hypermedia information systems. This setting is enabled by default.
Enable HTTPs
Select this checkbox to enable HTTPS access to the switch. Hypertext Transfer Protocol over Secure Socket Layer (HTTPS) is a Web protocol that encrypts and decrypts user page requests.This setting is enabled by default.
Page 318
7-4
Switch Management
Trustpoint
Use the Trustpoint drop-down menu to select the local or default trustpoint or used with the HTTPS session with the switch. For information on creating a new certificate for use with the switch, see Creating Server Certificates on page 6-77.
Enable FTP
Select this checkbox to enable FTP access to the switch. File Transfer Protocol (FTP) is the language used for file transfers across the Web. This setting is disabled by default.
Port
Define the port number used for the FTP session with the switch (if using FTP).
Root Dir.
Define the root directory where the FTP server is located (if using FTP).
Enable SSH
Select this checkbox to enable SSH access to the switch. Secure Shell (SSH) is a program designed to perform a number of functions, such as file transfer between computers, command execution or logging on to a computer over a network. It is intended to do these tasks with greater security than programs such as Telnet or FTP. This setting is enabled by default.
Port
Define the port number used for the SSH session with the switch.
RSA Key Pair
Use the RSA Key Pair drop-down menu to define either a Unset or default_ssh_rsa_key for secure communications during the SSH session with the switch.
NOTE
You cannot establish a SSH session with the switch when a RSA Key with a length of 360 is associated with the SSH-Server.
3. Click the Apply button to save changes made to the screen since the last saved configuration. 4. Click the Revert button to revert the screen back to its last saved configuration. Changes made since the contents of the screen were last applied are discarded.
Page 319
Switch Management
7-5
7.3 Configuring SNMP Access The SNMP Access menu allows you to view and configure existing SNMP v1/v2 and SNMP v3 details and their current access control details. You can also view the SNMP V2/V3 events and their current values. The SNMP Access window consists of the following tabs: • • •
!
Configuring SNMP v1/v2 Access Configuring SNMP v3 Access Accessing SNMP v2/v3 Statistics CAUTION Your system must be running Sun JRE version 1.5.x (or higher) or Mozilla in order for the switch Web UI to be used with the WS5100 3.0 baseline SNMP interface. NOTE
The WS5100 Series Switch SNMP facility cannot retrieve a configuration file directly from its SNMP interface. You must first deposit the configuration file to a computer, then FTP the file to the switch.
7.3.1 Configuring SNMP v1/v2 Access Refer to the v1/v2c screen for information on existing SNMP v1/v2 community names and their current access control settings. Community names can be modified by selecting a community name and clicking the Edit button. NOTE
The SNMP undo feature is not supported.
To review existing SNMP v1/v2 definitions: 1. Select Management Access > SNMP Access > v1/v2 from the main menu tree.
Page 320
7-6
Switch Management
2. Refer to the Community Name and Access Control fields for the following information: Community Name
Displays the read-only or read-write name used to associate a siteappropriate name for the community. The name is required to match the name used within the remote network management software. Click the Edit button to modify an existing Community Name.
Access Control
The Access Control field specifies a read-only (R) access or read/ write (RW) access for the community. Read-only access allows a remote device to retrieve information, while read/write access allows a remote device to modify settings. Click the Edit button to modify an existing Access Control.
3. Highlight an existing entry and click the Edit button to modify the properties of an existing SNMP V1/ v2 community and access control definition. For more information, see Editing an Existing SNMP v1/ v2 Community Name on page 7-6.
7.3.1.1 Editing an Existing SNMP v1/v2 Community Name The Edit screen allows the user to modify a community name and change its read-only or read/write designation. Since the community name is required to match the name used within the remote network management software, it is recommended the name be changed appropriately to match a new naming (and user) requirement used by the management software. To modify an existing SNMP v1/v2 Community Name and Access Control setting: 1. Select Management Access > SNMP Access> v1/v2 from the main menu tree. 2. Select an existing Community Name from those listed and click the Edit button.
3. Modify the Community Name used to associate a site-appropriate name for the community. The name revised from the original entry is required to match the name used within the remote network management software. 4. Modify the existing read-only (R) access or read/write (RW) access for the community. Read-only access allows a remote device to retrieve information, while read/write access allows a remote device to modify settings. 5. Click OK to save and add the changes to the running configuration and close the dialog. 6. Refer to the Status field for the current state of the requests made from applet. This field displays error messages if something goes wrong in the transaction between the applet and the switch 7. Click Cancel to return back to the SNMP v1/v2 screen without implementing changes.
Page 321
Switch Management
7-7
7.3.2 Configuring SNMP v3 Access Refer to the v3 screen to review the current SNMP v3 configuration. An Existing User Name can be selected and edited, enabled or disabled. . NOTE
The SNMP undo feature is not supported in this product.
To review existing SNMP v3 definitions: 1. Select Management Access > SNMP Access from the main menu tree. 2. Select the v3 tab from within the SNMP Access screen.
3. Refer to the fields within the v3 screen for the following information: User Name
Displays a read-only SNMP v3 username of operator or Admin. Operator typically has an Access Control of read-only and Admin typically has an Access Control of read/write.
Access Control
Displays a read-only (R) access or read/write (RW) access for the v3 user. Read-only access allows the user (when active) to retrieve information, while read/write access grants the user modification privileges.
Authentication
Displays the current authorization scheme used by this user for v3 access to the switch. Click the Edit button to modify the password required to change the authentication keys.
Encryption
Displays the current Encryption Standard (DES) protocol the user must adhere to for SNMP v3 access to the switch. Click the Edit button to modify the password required to change the encryption keys.
Status
Displays whether this specific SNMP v3 User Name is currently active. For more information, see Accessing SNMP v2/v3 Statistics on page 7-9.
Page 322
7-8
Switch Management
4. Highlight an existing v3 entry and click the Edit button to modify the password for the Auth Protocol and Priv Protocol. For additional information, see Editing an Existing SNMP v1/v2 Community Name on page 7-6 5. Highlight an existing SNMP v3 User Name and click the Enable button to enable the log-in for the specified user. When selected the status of the user is defined as active. 6. Highlight an existing SNMP v3 User Name and click the Disable button to disable the log-in for the specified user. When selected the status of the user is defined as inactive.
7.3.2.1 Editing a SNMP v3 Authentication and Privacy Password The Edit screen enables the user to modify the password required to change the authentication keys. Updating the password requires logging off of the system. Updating the existing password creates new authentication and encryption keys. To edit an SNMP v3 user profile: 1. Select Management Access > SNMP Access from the main menu tree. 2. Select the v3 tab from within the SNMP Access screen. 3. Highlight an existing SNMP v3 User Name and click the Edit button.
The Authentication Protocol is the existing protocol for the User Profile. The Authentication Protocol is not an editable option. The Privacy Protocol is the existing protocol for the User Profile. The Privacy Protocol is also not an editable option. 4. Enter the Old Password used to grant Authentication Protocol and Privacy Protocol permissions for the User Profile. 5. Enter the New Password, then verify the new password within the Confirm New Password area. 6. Click OK to save and add the changes to the running configuration and close the dialog. 7. Refer to the Status field for the current state of the requests made from applet. This field displays error messages if something goes wrong in the transaction between the applet and the switch. 8. Click Cancel to close the dialog without committing updates to the running configuration.