Page 697

AP-300 Sensor Conversion 15.1 Overview WS5000 switch is capable of adopting different types of Access Ports. It is capable of using custom firmware instead of default firmware images for specified APs. This functionality is used to perform the conversion from an AP to an W-IPS sensor. A new conversion firmware image is added to the WS5000 distribution. This image is similar to all other firmware images that are used by the switch to adopt the variety of APs.This image contains standard WS5000 image header that identifies the image as AP300 firmware. The image version in the header is set to 0.0.0.0. This prevents it from being used as a default image during AP300 adoption. The firmware is provided by AirDefense and contains the code necessary for AP300 to operate in the W-IPS sensor mode.

15.1.1 Sensor Implementation The switch can convert an AP300 to a W-IPS sensor and vice-versa. The conversion of an AP300 to a sensor is possible only on the currently active AP’s.

Page 698

15-2

WS5000 Series Switch System Reference Guide

15.2 Functionality In addition to the basic AP to sensor conversion it is also desirable that the switch provide some minimal management capabilities for the sensors. You should be able to view the list of sensors, read and send sensors' configuration and revert selected sensors back to AP. AirDefense defines Layer 2 communication protocol that can be used to discover sensors connected to the switch and to send commands to the sensors. A broadcast ping packet is used for sensor discovery, which implies that the sensors must stay in the same broadcast domain as the switch after the conversion. This is not an unreasonable expectation because AP adoption and subsequent conversion to a sensor would not be possible without it. This extended sensor management functionality has minimal potential impact on the core WS5000 functionality.The switch maintains the list of known sensors in a separate list that does not interfere with an existing list of AP's.

15.2.1 Sensor Discovery The switch discovers sensors by sending PINGREQUEST packets on all VLAN's connected to the switch. The switch dynamically obtains the list of all known VLAN's from the switch Ethernet configuration. All sensors that are reachable by the switch respond with PINGRESPONSE packet. The switch then sends REQ_CONFIG command to all discovered sensors. The switch maintains the list of all sensors and their configuration.The list is refreshed on a regular basis. The content of the list is returned to UI/CLI via an XML command

15.2.2 Sensor Configuration Sensor configuration consists of: •

DHCP or Static IP address

•

IP/mask/gateway for Static IP

•

Primary and secondary IP address of AirDefense server

The configuration is sent to a sensor after the initial conversion and at any other time based on user's request. The switch persistently stores a single default configuration that is sent to every sensor immediately after the conversion. The switch does not store per-sensor configuration. You can also interactively request for configuration of an individual sensor, modify it and send it back to the sensor. After the conversion, the switch continuously ping newly converted sensor by sending unicast PINGREQUEST packets to the MAC address on the VLAN in which the AP300 has been created. After the switch receives PINGRESPONSE from the sensor it sends CONFIG_UPDATE command to the sensor and waits for an acknowledgement. That completes the initial configuration after the conversion. If the switch fails to receive PINGRESPONSE after 10 seconds of conversion or if the switch fails to receive an acknowledgement after the switch logs an error. You can select one of the sensors to change its configuration.The switch issues REQ_CONFIG command and waits for a response. The response contains current sensor's configuration and you can make changes in it. After the changes are made the switch sends CONFIG_UPDATE command to the sensor and waits for an acknowledgement. If the switch fails to receive an acknowledgement it logs an error.

Page 699

AP-300 Sensor Conversion

15-3

15.2.3 Sensor Revert You can revert sensors back to AP's by selecting sensors from the list and issuing a revert command. The switch sends a DOWNGRADE command to all selected sensors and waits for an acknowledgement from every one of them. DOWNGRADE commands forces the sensor to reactivate WISP bootloader at which point AP300 can be adopted as an access port. If the switch failed to receive and ACK it logs an error. Note At any given time, you cannot send more than one configuration command to a sensor. The sensor resets after receiving the first command and is unavailable for 45 seconds.

15.3 GUI and CLI Interface The actions related to sensor configuration and revert are performed asynchronously and outside the normal interaction between the switch and UI/CLI. Its because of this, the switch returns success for any command that has valid syntax and parameters, i.e. valid MAC address of the sensor, valid IP/network mask/gateway, etc. The command itself is executed after the initial result is returned to UI/CLI. For complete CLI reference see 8.47 Sensor Context on page 252 The convert and revert command take some time for completion. When you issue a convert command using CLI, you get a success. This means the command has been accepted and the syntax and MAC address is valid. It will take anywhere between 45 seconds upto a minute to complete the conversion. Hence the newly converted AP will get displayed in the sensor list only after about a minute. A syslog/SNMP trap is generated whenever the sensor is disconnected anytime during the period when it was discovered and the moment you attempt to issue a command to the sensor. Note All the sensor conversion and management related functionality is disabled by default. User is required to enable it through UI/CLI command before using any of the described functionality. Configuration through SNMP is also supported.

15.3.1 Converting an AP300 into a Sensor To convert an AP300 to a sensor, select AP300/Sensor from the left hand side tree menu of the main window. This will open AP300/Sensor configuration window. By default the window displays the AP300 tab details. Follow the steps mentioned below to convert an AP300 to a sensor:

Page 700

15-4

WS5000 Series Switch System Reference Guide

1. The sensor conversion and management functionality is disabled by default. Select Enable from the Enable Sensor drop-down box, this will enable you to convert the AP300 to a sensor.

Figure 15.1 AP300/Sensor window

2. Select an AP300 by clicking on the checkbox associated with each AP300. Click on the Default Config button to view the default configuration of the sensor. This opens the WIPS Default Configuration

Page 701

AP-300 Sensor Conversion

15-5 window. All the fields in this window are configurable and you can change the default configuration if required and commit it by clicking on the Save button.

Figure 15.2 The WIPS Default configuration window

Note If you enable the DHCP, then you cannot edit Sensor IP, Subnet Mask and Gateway fields.

Page 702

15-6

WS5000 Series Switch System Reference Guide

3. Click on the Convert to Sensor button to convert the selected AP300 into a sensor. This opens the WIPS Configuration window. Click on the Save button to commit the changes made.

Figure 15.3 The WIPS Configuration window

4. The switch opens a dialog box prompting you to confirm the changes made. Click OK to confirm the changes made (if any) and save the configuration to start the conversion from an AP to W-IPS. Note If you enable the DHCP server type in the WIPS Configuration window, the Sensor IP, Subnet Mask, Gateway will be disabled. These values will now be provided by the DHCP server.

Page 703

AP-300 Sensor Conversion

15-7

5. To view the new sensor, click on the AP300/Sensor from the tree menu on the left hand side. Select the Sensor tab and then click on the Refresh button in the main AP300/Sensor window. It generally takes about a minute to convert the AP into a sensor.

Figure 15.4 Viewing the newly created sensor in the Sensor tab

15.3.2 Converting an Sensor into AP300 To convert an sensor to a AP300, select AP300/Sensor from the left hand side tree menu of the main window. This will open AP300/Sensor configuration window. Click on the Sensor tab to view the list of sensors available. Follow the steps mentioned below to convert an sensor to a AP300: 1. Select Enable from the Enable Sensor drop-down box, this will enable you to convert the sensor to a AP300.

Page 704

15-8

WS5000 Series Switch System Reference Guide

Figure 15.5 Sensor tab displaying the available sensor(s)

2. Select an sensor by clicking on the checkbox associated with the sensor that you want to convert to an AP300. Click on the Modify button to view the current/default configuration of the sensor. This opens the WIPS Configuration window. Disable the DHCP, by clicking on the checkbox, to modify the values of Sensor IP and Subnet Mask . If the DHCP server is enabled then these values (Sensor IP and Subnet Mask ) is provided by DHCP and you cannot modify it. Click the Save button to commit the changes made, if any.

Figure 15.6 The default WIPS Configuration window displaying the default sensor configuration

Page 705

AP-300 Sensor Conversion

15-9

3. The switch opens a dialog box prompting you to save the configuration. Click OK to confirm the changes made (if any) and save the configuration.

Figure 15.7 Converting a Sensor to an AP300

4. To view the new AP300,click on the AP300/Sensor from the tree menu on the left hand side.Select the AP300 tab and then click on the Refresh button in the main AP300/Sensor window. It generally takes about a minute to convert the sensor into a AP300.

Page 706

15-10

WS5000 Series Switch System Reference Guide