Page 691

Enhanced RF Statistics

14-41

Figure 14.13 Without the antenna, many packets had 1 to 4 retries.

The “raw” stats also accumulate the number of packets received, the sum of all signal values on those packets, and the sum of all each signal value squared. Taking the delta of each of those values over both the interval with the antenna present and absent, results in average signal readings with corresponding standard deviations. With the antenna absent, the average signal was –88.5 dB with a stddev of 3.4, (meaning that 67% of packets had signal values of –91.9 to –85.1 dB). Note The greater variance while the antenna is present can be explained by the fact that the AP radio has a certain floor of receive sensitivity, probably around – 91 dB. This fact compresses the range of possible values. With the antenna present, the average signal was –63.6 with a stddev of 10.2 dB. Assuming the signal readings fit a normal distribution, those curves would look approximately as shown in Figure 14.14. Note that these values match very close to the values, (–89 and –67 dB), shown in Figure 14.10.

Page 692

14-42

WS5000 Series Switch System Reference Guide

Figure 14.14 Distributions of received signal strength, as predicted by the average and standard deviationcalculated across the collection of packets received.

14.6.1.1 Watching min, max, or average is not enough Suppose your SLA (Service Level Agreement) states to provide a wireless signal strength of –63dB (or better) to your customers partners/colleagues. What variables would you need to monitor to assure all involved that the agreed service level was being achieved?

SLA 1, End stations will experience –63dB or better Monitoring min/max would not suffice. In most wireless infrastructures, this would tell you nothing as at least one end station would have experienced –20dB (or some such excellent signal), and at least one end station would have experienced –90dB (or some such signal at the very threshold of being detected). Monitoring the mean would also not suffice. Figure 14.15 shows three possible scenarios. In the red case, all end stations are experiencing a very similar level of signal ranging from –53dB to –63dB. In the blue case, some are experiencing very strong signal while an equal number are experiencing very weak signal. Note that in all cases the mean is identical. Process control theory has addressed many such problems for decades using standard deviation. For any normal distribution, 68% of the population resides in the range of mean +/– one standard deviation. 95% of the population resides in the range of mean +/– two standard deviations, and 99.7% within three standard deviations. Note Six standard deviations include all but two billionths of the sample. Due to the quality control methodology called ‘Six Sigma’, the term has acquired a commonplace meaning as containing 99.99966% of the sample. Many corporations have adopted the Six Sigma methodology for Quality Control and try to achieve a defect rate of 3.4 per million. The rate of 3.4 per million, however, actually corresponds to 4.5 standard deviations, because the Six Sigma founders assumed a natural offset of 1.5 sigma to account for drift in production quality over time.

Page 693

Enhanced RF Statistics

14-43

Figure 14.15 Graph dispalying the 3 possible scenarios while monitoring the signal strenght

This begs the question: what percentage of end stations must be experiencing –63dB or better at any given time? Depending on the situation, the requirement might be that 80% must have 63dB or better, (which the red and green distributions achieve). Or, the requirement might be that 98% have better than –63dB, (which only the red distribution achieves).

SLA 2, 80% of end stations will experience –63dB or better In any case, both the mean and the standard deviation must be monitored. If success was defined as having 80% of the end stations at –63dB or better, that would suggest that the mean of the measured signal strengths needs to be at least one standard deviation better than –63dB; (since +/– one standard deviation accounts for 68% of a normally distributed population, that means one ‘tail’ would leave 32% / 2 = 16%, which is just slightly better than the 20% we permit to be worse than –63dB). So, to ensure that our threshold is met, we routinely fetch the mean and standard deviation from the wireless infrastructure and check that mean + [one] standard deviation is less than or equal to – 63dB.10.

14.6.1.2 Who calculates Standard Deviation? There are two possibilities: the network infrastructure devices themselves, or an external, server-based network management application. When a SLA is negotiated, it must specify not just the threshold, (–63dB in our example), and the percentage of the population in compliance, (80% in our example), but also the monitoring interval. An environment that

Page 694

14-44

WS5000 Series Switch System Reference Guide has 80% of the end stations at –63dB or better as averaged over a 24 hour period may not have met that standard each and every hour of that day.

SLA 3, Within each 30 seconds interval, 80% of end stations will experience -63dB or better Whatever interval the SLA specifies is the minimum interval at which monitoring must take place. Since those intervals are often relatively short, it would clearly be more efficient for the network infrastructure device to perform this monitoring, rather than an external server. For the infrastructure to do this well, it would allow the threshold (-63dB in our case) to be specified, as well as the number of standard deviations, (1 in our case), which the current mean should be from the threshold. If standard deviation is relatively constant, solely the mean could be monitored, (but for many installations that might be a big assumption). Additionally, it’s important that the infrastructure device ignore any calculations that are performed on too few packets to be statistically significant. A time-period that only represents 5 packets is meaningless, regardless of the mean and/or standard deviation.

14.6.1.3 How is Standard Deviation calculated from running sums? In order to calculate the mean, for efficiency reasons the network infrastructure device would typically maintain a total sum of received signal strengths, and ‘n’, the number of readings/packets. Such running sums are much more efficient to maintain than re-calculating the mean after each new reading/packet. Note Re-calculating average and stddev after each new sample would require several multiplication, division, and square-root calculations for each packet. Keeping a running sum and sum-of-squares requires only two additions per packet, and a lookup (in place of the squaring function). Additionally, using sum and sum-of-squares allows the average and standard deviation to be calculated over any arbitrary interval of time. Note Note that this would not be possible if the device were maintaining a ‘running’ average and ‘running’ standard deviation. The delta calculation: endaverage – start-average does not yield the average over a given interval of time. Likewise for standard deviation. Mean (average) can be easily calculated at any time by dividing the sum of readings by ‘n’. Standard deviation can be calculated from ‘n’, the sum of all readings, and the sum of each reading squared.

Page 695

Enhanced RF Statistics

Or, in terms more suited to a programmer, rather than a math major: // at start of the time interval GET start-n, start-sum-of-values, start-sum-of-squares : // wait for the time interval to expire : // at end of the time interval GET end-n, end-sum-of-values, end-sum-of-squares // calculate the delta of readings over the interval n = end-n - start-n sum-of-values = end-sum-of-values – start-sum-of-values sum-of-squares = end-sum-of-squares – start-sum-of-squares // calculate average & stddev mean = sum-of-values / n std-dev = SQRT( (sum-of-squares – (n * mean * mean)) / (n – 1) )

14-45

Page 696

14-46