Page 30

Chapter 4 Installing Software This chapter describes how to install application programs onto a terminal. VRC 6940 terminals have a number of drives available for storing user applications and data. For more information on available drive space, the software environment and a list of standard VRC 6940 software, see Appendix B, Software Environment. Before you begin, read the procedures in this chapter all of the way through.

Equipment Required To transfer applications, you need: !

a VRC 6940 terminal

!

a Host PC

!

an RS-232 serial null modem cable with a 16-pin male connector at one end, and a 25-pin female connector at the other end

!

a reliable power supply

!

software for transferring files from a Host PC to the terminal

See Table 4-1 for information on recommended software. Also see the Series 3000 Application Programmer's Reference Manual (p/n 70-16309-XX). Table 4-1. Software Required for Transferring Files Type of File to be Transferred

Host PC Software

VRC 6940 Software

HEX Image

SENDHEX or WINHEX

Program Loader

Other file types

TFT3000

TDREM

4-1

Page 31

VRC 6940 Product Reference Guide

Transferring and Installing Application Programs This section describes how to transfer a HEX image from a Host PC onto a VRC 6940 terminal over a standard RS-232 null modem cable. The procedure uses the SENDHEX or WINHEX program on the Host PC and the Program Loader utility on the VRC 6940. The Program Loader installs the HEX image by converting the ASCII data stream into files that are stored in non-volatile memory (NVM) on the terminal (the application EEPROM). Any further installation procedures depend on the contents of the HEX file. To transfer non-HEX images or files, use the TFT3000 program on the Host PC, and the TDREM utility on the terminal. For details on all of these programs, refer to the Series 3000 Application Programmer’s Reference Manual (p/n 70-16309-XX).

Laptop Computer

VRC 6940 RS-232 serial port Null modem cable To the serial port

Figure 4-1. Cabling for Downloading on Benchtop

1. Prepare the PC for Communications and File Downloading To prepare the PC for communications: 1. Begin with the VRC 6940 terminal in suspend mode. 2. Remove the plug cover from the RS-232 serial port on the terminal, and attach the male connector end of the null modem cable. 3. Attach the female end of the null modem cable to the Host PC serial port, as shown in Figure 4-1. Use an adapter, if necessary. 4. On the PC, start the communications program. For example, to use SENDHEX, first open a DOS window. Then type the SENDHEX command with appropriate 4-2

Page 32

Installing Software parameters, and press ENTER. The example in Figure 4-2 shows a baud rate of 38400, and the COM2 option. For pgmname, type the name of the HEX file you are transferring, without the .hex extension. The default parameter values are: "

9600 bps

"

COM1

"

7 data bits

"

Odd parity

"

Xon/Xoff flow control C:\>cd\ sendhex pgmname 38400 com2

SENDHEX Command

HEX File Name (no .hex extension)

COM Port Baud Rate

Figure 4-2. Setting up Communications with SENDHEX Note: Versions of SENDHEX earlier than version 3.0 do not support flow control. If you are using an earlier version, and errors appear, use a lower baud rate. 5. A prompt appears as shown in Figure 4-3. Do not press ENTER yet. You must set up the VRC 6940 terminal next, as described in the next section. C:\>cd\ sendhex pgmname 38400 com2 Version: 3.01-01 Press <Enter> when remote is ready. ESC to abort...

Figure 4-3. The SENDHEX Prompt

4-3

Page 33

VRC 6940 Product Reference Guide

2. Provide a Reliable Power Source If you have not already done so, install the terminal hardware and provide a reliable power source, as described in Chapter 2. If the terminal is mounted on a vehicle, it can remain mounted as long as the internal battery is fully charged (see page 2-8) and you can position it close enough to the Host PC for the cables to reach. Otherwise, remove it from the vehicle, position it on a workbench and provide operating power with a Symbol AC Universal Power Supply. Note: If there is a power interruption during the file transfer process, restore the power and start again at step three (Prepare the Terminal for Transferring Files).

3. Prepare the Terminal for Transferring Files This section describes how to run the Program Loader utility on a VRC 6940 terminal, so the terminal can receive files transferred from a Host PC. To set up the terminal: 1. Boot the VRC 6940 into Command Mode: a. With the terminal in suspend, press and hold the A and D keys. b. Press and release the ON/OFF key. c. Release the A and D keys. 2. The terminal boots to the Command Mode screen, shown in Figure 4-4.

Installation Note: Using Menus To navigate the menus: • Press UP or DOWN arrow keys to scroll through options. • To return to the previous menu, press CLEAR.

COMMAND MODE Select Function Self Test

Figure 4-4. Command Mode screen

4-4

Page 34

Installing Software

3. Press UP or DOWN arrows to scroll through Command Mode options until you see the Program Loader option. Then press ENTER to display the message shown in Figure 4-5. Program Loader WARNING: EEPROM WILL BE ERASED CONTINUE? <ENT>

Figure 4-5. Erasing NVM (EEPROM) 4. When you are ready to erase EEPROM, press ENTER. This message appears: Program Loader Erasing EEPROM Please wait....

The program erases the EEPROM and prompts you for communications parameters.

Installation Note: Before you Erase EEPROM If you have not configured the Spectrum24 radio card for the terminal, press CLEAR to cancel the operation, and configure the radio card now (see page 3-2). When you run the Program Loader and press ENTER, it erases the EEPROM (non-volatile memory). You must erase the EEPROM before you can transfer the HEX file onto the terminal.

5. Set the communications parameters to 38400 bps, 7 data bits, odd parity and Xon/Xoff flow control. a. Baud Rate: Select 38400. The screen will look like this: Comm Parameters Baud 6 38400

Figure 4-6. Setting Baud Rate on the VRC 6940

4-5

Page 35

VRC 6940 Product Reference Guide b. Data Bits: Select 7. The screen will look like this: Comm Parameters Data Bits 7

Figure 4-7. Setting Data Bits on the VRC 6940 c. Parity: Select Odd. The screen will look like this: Comm Parameters Parity Odd

Figure 4-8. Setting Parity on the VRC 6940 d. Flow Control: Select Xon/xoff. The screen will look like this: Comm Parameters Flow Control Xon/xoff

Figure 4-9. Setting Flow Control on the VRC 6940 6. When all parameters are set, the screen displays this message: Program Loader Start? <ENT>

7. Press ENTER to start the Program Loader.

4-6

Page 36

Installing Software

4. Start the File Transfer 1. On the Host PC, press ENTER to start the transfer. The Host PC displays this message: C:>\ Bytes sent = xxxx xx%

If the Host PC is not ready or the cable is disconnected between the PC and the terminal, the PC displays this message: Awaiting DSR

In this case, check the cable connection and then press ENTER again on the Host PC to start the download. 2. During the transfer, the VRC 6940 terminal displays these messages: Program Loader Receiving :xxxx

Check the status on both the terminal and the Host PC during data transmission. They should both show program segment addresses being transferred (XXXX). If this does not happen, then the data is not transferring correctly. 3. When the transmission is complete, the terminal displays a status code. A successful download shows a status of 0000. This message appears: Program Loader Status 0000

Any other value indicates a failed transfer. See Appendix E, Communications Status Codes.

Failed Transfers If a file transfer finishes with a status value other than 0000, then the transfer was not successful. In this case: 1. Check cable connections between the VRC 6940 terminal and the Host PC. Make sure the null modem cable is connected to the correct port on the Host PC. 2. Repeat the transfer steps using a lower baud rate (e.g., 19200). 3. If the problem persists, contact Symbol Technical Support for assistance.

4-7

Page 37

VRC 6940 Product Reference Guide

Successful File Transfer Following a successful file transfer, the files must be copied to the flash disk before you can use them. This happens the next time the terminal is re-initialized (cold booted). See 5. Complete the Installation of Transferred Files , next.

5. Complete the Installation of Transferred Files To complete the installation of transferred files, you must re-initialize (cold boot) the terminal. To do this: 1. Disconnect the null modem cable from the VRC 6940 terminal and Host PC. 2. Replace the terminal plug cover for the serial port on the VRC 6940. 3. Perform a cold boot: a. Press and hold the ENTER, F1 and F4 keys. b. Press and release the ON/OFF key. c. Release the ENTER, F1 and F4 keys. 4. When the terminal restarts, it boots according to the applications you have loaded. For more information, refer to the documentation for the applications.

4-8