Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 3 of 3

VRC 6940 Terminal Quick Reference, pages 17 to 24

Pages 17 to 24 of 24

The original document is the PDF (789 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol VRC-6940

Page 17

Q u i c k

R e f e r e n c e b. Route the External DC power cable from the terminal location to the connection point for your vehicle’s power source. ! Installation Note: Cable Routing Caution ! The means of routing and securing the External DC power cable from the terminal to the vehicle power source is extremely important. Hazards associated with improper wiring can be severe. To avoid unintentional contact between the wire and any sharp edges, provide the cable with proper bushings and clamping where it passes through openings. If the wire is subjected to sharp surfaces and excess engine vibration, the wiring harness insulation can wear away, causing a short between the bare wire and chassis. This can start a fire.

c. Prepare the cable termination: Strip 3/8” of insulation from the two wire ends and terminate them with a connector that matches your vehicle’s requirements. See the Installation Note below. Connect the red wire to the vehicle power source. Connect the black wire to a vehicle ground wire or chassis ground. Installation Note: Cable Termination How the cable terminates depends on your vehicle. If your vehicle has a power output connector, then attach a mating connector to the end of the power cable. You may be able to connect to a fuse panel with a commercially available connector. If your vehicle has no power output connector, attach a ring terminal (for a battery post) or blade terminal connector (for a fuse panel). Consult your vehicle Owner’s Manual for information on how to access your vehicle’s power supply.

d. Connect the External DC power cable to your vehicle power source. 3. Insert the terminal end of the External DC power cable into the terminal’s Power Connector. Align the red dot on the end of the power cable with the red dot on the Power Connector.

15

Page 18

V R C

6 9 4 0

T e r m i n a l

WARNING A Lead Acid battery can leak Hydrogen gas. A spark anywhere near the battery can cause it to explode. Always make your final connection to power as far away from the battery as possible, i.e., connect the power cable to the battery first, then connect it to the terminal.

Providing Power: Wall or Workbench Installations For wall or bench-mounted terminals, or for operating a terminal while away from a vehicle, you can operate an VRC 6940 from an AC universal power supply. You need the AC universal power supply, an AC line cable, and a DC power cable as listed on page 9. To provide power from an AC source: 1. Insert the AC line cable into the AC connector on the AC universal power supply. 2. Plug the other end of the AC line cable into an AC wall outlet. 3. Insert the DC power cable into the DC connector on the AC universal power supply. 4. Plug the other end of the cable into the terminal’s Power Connector.

Installation and the Internal Battery A terminal’s internal battery may be depleted when you first install it. The internal battery charges itself from the terminal’s main power supply (DC or AC). If the main power supply is stable, you can plug in the terminal and use it immediately. If the main power supply is not stable, there may be power interruptions that cause the terminal to reset itself during its first few hours of operation. If the terminal resets itself, you may lose unsaved data. To avoid this, we recommend that you plug in the terminal and allow it to charge for two hours before using it. 16

Page 19

Q u i c k

R e f e r e n c e

It takes 48 hours to fully charge the internal battery. A fully charged internal battery maintains data for up to 72 hours if the unit is disconnected from its main power source. This time is reduced if the radio is in a mode where it maintains continuous communication with a host.

Ergonomic Recommendations Caution: In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are adhering to your company's safety programs to prevent employee injury. • Reduce or eliminate repetitive motion • Maintain a natural position • Reduce or eliminate excessive force • Keep objects that are used frequently within easy reach • Perform tasks at correct heights • Reduce or eliminate vibration • Reduce or eliminate direct pressure • Provide adjustable workstations • Provide adequate clearance • Provide a suitable working environment • Improve work procedures.

17

Page 20

V R C

6 9 4 0

T e r m i n a l

Regulatory Information All Symbol devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to Symbol Technologies equipment, not expressly approved by Symbol Technologies, could void the user's authority to operate the equipment.

Radio Frequency Interference Requirements Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable FOR HOME OR OFFICE USE protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help. Tested to comply with FCC Standards

Radio Frequency Interference Requirements - Canada This device complies with RSS 210 of Industry & Science Canada. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Label Marking: The Term "IC:" before the radio certification only signifies that Industry Canada technical specifications were met.

18

Page 21

Q u i c k

R e f e r e n c e

FCC RF Exposure Guidelines Remote and Standalone Antenna Configurations To comply with FCC RF exposure requirements, antennas that are mounted externally at remote locations or operating near users at stand-alone desktop of similar configurations must operate with a minimum separation distance of 20 cm from all persons.

Marking and European Union Compliance RLAN's (2.4GHz) for use through the EEA have the following restrictions: • Maximum radiated transmit power of 100 mW EIRP in the frequency range 2.400 -2.4835 GHz • France, equipment is restricted to 2.4465 -2.4835 GHz frequency range • Belgium outside usage, the equipment is restricted to 2.460 -2.4835 GHz frequency range • Italy requires a user license for outside usage.

Statement of Compliance Symbol Technologies, Inc., hereby, declares that this device is in compliance with the essential requirements and other relevant provisions of Directives 1999/5/EC, 89/ 336/EEC, 73/23/EEC and 95/54/EC. Declaration of Conformities may be obtained from http://www2.symbol.com/doc/ Other Countries Mexico - Restrict Frequency Range to: 2.450 - 2.4835 GHz. Israel - Restrict Frequency Range to: 2.418 - 2.457 GHz. Sri Lanka - Restrict Frequency Range to: 2.400 - 2.430 GHz.

19

Page 22 read from a scan by OCR; it may hold reading errors

R

Cc

69 4 0

20

Te r m nia

Page 23

Q u i c k

R e f e r e n c e

Warranty (A) Seller's hardware Products are warranted against defects in workmanship and materials for a period of twelve (12) months from the date of shipment, provided the Product remains unmodified and is operated under normal and proper conditions. Warranty provisions and durations on software, integrated installed systems, Product modified or designed to meet specific customer specifications ("Custom Products"), remanufactured products, and reconditioned or upgraded products, shall be as provided in the applicable Product specification in effect at the time of purchase or in the accompanying software license. (B) Products may be serviced or manufactured with parts, components, or subassemblies that originate from returned products and that have been tested as meeting applicable specifications for equivalent new material and Products. The sole obligation of Seller for defective hardware Products is limited to repair or replacement (at Seller's option) on a "return to service depot" basis with prior Seller authorization. Shipment to and from Seller will be at Seller's expense, unless no defect is found. No charge will be made to Buyer for replacement parts for warranty repairs. Seller is not responsible for any damage to or loss of any software programs, data or removable data storage media, or the restoration or reinstallation of any software programs or data other than the software, if any, installed by Seller during manufacture of the Product. The aforementioned provisions do not extend the original warranty period of any Product that had either been repaired or replaced by Seller. (C) The above warranty provisions shall not apply to any Product (i) which has been repaired, tampered with, altered or modified, except by Seller's authorized service personnel; (ii) in which the defects or damage to the Product result from normal wear and tear, misuse, negligence, improper storage, water or other liquids, battery leakage or failure to perform operator handling and scheduled maintenance instructions supplied by Seller; (iii) which has been subjected to unusual physical or electrical stress, abuse, or accident, or forces or exposure beyond normal use within the specified operational and environmental parameters set forth in the applicable Product specification; nor shall the above warranty provisions apply to any expendable or consumable items, such as batteries, supplied with the Product. EXCEPT FOR THE WARRANTY OF TITLE AND THE EXPRESS WARRANTIES STATED ABOVE, SELLER DISCLAIMS ALL WARRANTIES ON PRODUCTS FURNISHED HERUNDER INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABLILTY AND FITNESS FOR A PARTICULAR USE. ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD. SOME STATES OR COUNTRIES DO NOT ALLOW A LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS. IN SUCH STATES OR COUNTIRES, FOR SUCH PRODUCTS, SOME EXCLUSIONS OR LIMITATIONS OF THIS LIMITED WARRANTY MAY NOT APPLY. The stated express warranties are in lieu of all obligations or liabilities on the part of Seller for damages, including but not limited to, special, indirect or consequential damages arising out of or in connection with the use or performance of the Product or service. Seller's liability for damages to Buyer or others resulting from the use of any Product or service furnished hereunder shall in no way exceed the purchase price of said Product or the fair market value of said service, except in instances of injury to persons or property.

21

Page 24

Service Information Before you use the unit, it must be configured to operate in your facility’s network and run your applications. If you have a problem running your unit or using your equipment, contact your facility’s Technical or Systems Support. If there is a problem with the equipment, they will contact the Symbol Support Center: United States1

1-800-653-5350 1-631-738-2400

Canada

905-629-7226

United Kingdom

0800 328 2424

Asia/Pacific

+65-6796-9600

Australia

1-800-672-906

Austria/Österreich

1-505-5794-0

Denmark/Danmark

7020-1718

Finland/Suomi

9 5407 580

France

01-40-96-52-21

Germany/Deutchland

6074-49020

Italy/Italia

2-484441

Mexico/México

5-520-1835

Netherlands/Nederland

315-271700

Norway/Norge

+47 2232 4375

South Africa

11-8095311

Spain/España

Sweden/Sverige

84452900

Latin America Sales Support

1-800-347-0178 Inside US +1-561-483-1275 Outside US

Europe/Mid-East Distributor Operations

Contact local distributor or call +44 118 945 7360

91 324 40 00 Inside Spain +34 91 324 40 00 Outside Spain

1Customer support is available 24 hours a day, 7 days a week.

For the latest version of this guide go to: http://www.symbol.com/manuals.

72-37640-02 Revision C - October 2002 Symbol Technologies, Inc. One Symbol Plaza, Holtsville, N.Y. 11742-1300