The text of a manual · part 2 of 3
VRC 6940 Terminal Quick Reference, pages 9 to 16
Pages 9 to 16 of 24
The original document is the PDF (789 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol VRC-6940
Page 9
Q u i c k
Note:
R e f e r e n c e
If you unplug the power cable, and the internal battery is not charged, the terminal may shut off.
Troubleshooting Problem
Action
The terminal will not start.
Make sure that the terminal is connected to a power source. If the external power cable has come unplugged, plug it back in and press the ON/OFF key to restart the terminal. If the internal battery was charged, the terminal will maintain your session until you reconnect it to the power source and restart it. If the internal battery was not fully charged, you may have lost any unsaved data. If the terminal is connected to a vehicle battery as a power source, check the vehicle battery. If it is depleted (dead), replace the vehicle battery.
The start-up process fails.
The terminal may be out of range of the Access Point (AP) and unable to communicate with the host computer. Move closer to the AP. If either of these messages appears, contact your System Administrator:
Boot server doesn’t exist. Boot server not configured for this terminal. Application does not respond.
The terminal may not be connecting to the Access Point (AP). Applications function until they need to transmit to the AP, then they stop responding. Contact your System Administrator.
Scanner laser works but does not read bar codes.
The bar code on the label may not be clearly printed. Try scanning another label of the same product, or type in the bar code data manually. The scanner window may be dirty. Clean it with a soft, dry cloth moistened with an ammonia-based glass cleaner.
Scanner does not operate.
Make sure the scanner is properly connected to the terminal’s Scanner Connector. Then restart the terminal with the scanner connected.
7
Page 10
V R C
6 9 4 0
T e r m i n a l
Problem
Action
Power fault.
This message may appear if the terminal’s last shutdown was caused by power failure. A power failure can be caused by: • removing the terminal from the power source • removing the vehicle battery • sudden main battery failure If the internal battery is charged, it can maintain session data for up to 72 hours. You can replace the main power supply and restart the terminal without losing data. If the internal battery is not fully charged, the terminal may not be able to maintain session data, and you will lose any unsaved data. To recharge the internal battery, keep the main power connected to the unit for 48 hours.
Terminal suddenly shuts off or goes into suspend.
The terminal may be in suspend mode. Press the ON/OFF key to reactivate it. Check the main power supply and external power cable. If the cable is unplugged, plug it back in and press the ON/ OFF key to restart the terminal. If the terminal loses its connection with its main power source, it goes into suspend. The internal battery can maintain session data for up to 72 hours. However if the internal battery is not fully charged, the terminal may not maintain your session, and you may lose unsaved data. For more information, see Charging the Internal Battery on page 6 and Installation and the Internal Battery on page 16.
Installing a VRC 6940 Terminal This section describes how to install a VRC 6940 terminal into a vehicle or onto a wall or workbench. Please read all of these instructions before you begin.
WARNING A properly trained technician must perform the installation. Improper installation can damage your vehicle.
8
Page 11
Q u i c k
R e f e r e n c e
Equipment Required Vehicle Mounting • • • • • • •
VRC 6940 terminal. an External DC power cable (supplied with terminal). minimum of two 3/8” bolts with self-locking nylon nuts. a drill with a 7/16” drill bit. 7/16” hex wrench. a connector for terminating the External DC power cable. Select one that mates with your vehicle’s power supply. primary or external antenna (optional).
Wall or Workbench Mounting • • • • • • • •
VRC 6940 terminal. AC universal power supply (Symbol p/n 50-14001-006). AC line cable (Symbol p/n 23844-00-00). DC power cable (Symbol p/n 25-39385-01). minimum of two 3/8” bolts with self-locking nylon nuts. a drill with a 7/16” drill bit. 7/16” hex wrench. primary or external antenna (optional).
Hardware Installation The physical requirements of the work area affect where you place the terminal. There are different installation options, depending on where you plan to locate it. Illustrations on page 12 and 13 show a terminal mounted on a vehicle, a terminal mounted on a wall, and a terminal mounted on a workbench. Caution:
Do not install a VRC 6940 terminal in a location that will affect vehicle safety or driveability.
9
Page 12
V R C
6 9 4 0
T e r m i n a l
To install VRC 6940 hardware: 1. Prepare a mounting location: a. Select a location to mount the terminal. The terminal’s attached bracket has holes cut for bolts. Use these holes to mark bolt hole locations. b. Prepare the mounting surface to accept two 3/8” bolts. Drill two holes with a 7/16” drill bit. Installation Note: Selecting a Mounting Location The bracket and terminal must be:
• firmly secured to a surface that can support the weight of the terminal, on a vehicle, wall or workbench • secured with a minimum of two 3/8” diameter bolts and nylon self-locking nuts • easy for the end-user to see and reach
2. Install the terminal onto the mounting surface: a. Position the terminal on the mounting surface. b. Fasten it using a minimum of two 3/8” self-locking nuts.
10
Page 13
Q u i c k
R e f e r e n c e
F1
F2
F3
F4
F5
A
B
C
D
E
F
G
7
8
9
H
I
J
K
L
M
N
4
5
6
CLEAR
O
P
Q
R
S
T
U
1
2
3
ENTER
V
W
X
Y
Z
SHIFT
FUNC
-
0
.
BACK
ON/OFF
CTRL
3. Attach the Bracket Knobs. When you first unpack it, the terminal has hex bolts in place of the Bracket Knobs.These knobs allow users to adjust the angle of the terminal. a. Use a 7/16” hex wrench to remove the bolts and replace them with the Bracket Knobs.
11
Page 14
V R C
6 9 4 0
T e r m i n a l b. To adjust the angle of the display, partially unscrew the Bracket Knobs. Then adjust the angle of the terminal and re-tighten them. 4. Optional: attach a primary antenna to the connector at the top of the terminal. To attach the antenna: a. Place the metal end of the antenna onto the connector. b. Line the posts up with the connector and press down. c. Twist the bottom ring clockwise to lock it into position. Antenna Connector
Back of Terminal
5. Optional: install a vehiclemounted antenna. Sometimes you can improve wireless communication by mounting an external antenna onto the vehicle. Symbol has several different external antennas available. Contact your Support Representative for more information.
Antenna
Coaxial cable
To connect an external vehicle-mounted antenna: a. Secure the external antenna to an appropriate location on the vehicle.
12
Page 15
Q u i c k
R e f e r e n c e b. Connect one end of a coaxial cable to the terminal’s Antenna Connector. Connect the other end to the vehiclemounted antenna. Make the coaxial cable as short as possible to minimize signal loss.
Providing Power: Vehicle Installations VRC 6940 terminals can be powered by: • •
12V or 24V gas-powered vehicles battery-powered vehicles, up to 60 volts
To provide power to a vehicle-installed VRC 6940: 1. Locate your vehicle’s power source. Always connect a VRC 6940 terminal to a continuous or unswitched power source. Installation Note: Power Sources The ideal location for connecting a VRC 6940 External DC power cable would be a fused power source on the vehicle’s power distribution panel. If no fused power source is available, you can connect the terminal directly to a vehicle battery. In this case, Symbol recommends that you use an in-line fuse holder and 5A slow-blow fuse. The fuse protects your vehicle from an electrical short on the power cable.
2. Prepare the External DC power cable. One end of the external DC power cable fits into the terminal’s DC Power connector. The other end has no connector.
Plug in to the DC Power connector on the terminal
Cable End to be prepared
13
Page 16
V R C
6 9 4 0
T e r m i n a l
To prepare the end of the External DC power cable: a.
In-line fuse holder: if no fused output is available, add a fuse-holder and 5 Amp fuse to the External DC power cable: i. Strip back six inches of the cable jacket. ii. Cut about 5” from the red power wire and strip 3/8” insulation from the wire. iii. Strip 3/8” insulation from the fuse-holder wire. iv. Twist the stripped wire ends together and splice them using a twist-on nylon wire connector. v. Make sure the fuse holder contains a 5 Amp slowblow fuse. Wrap the wires neatly, as necessary.
Red power wire i.
ii.
In-line fuse holder with 5A slow-blow fuse
Twist-on nylon wire connector
Wrapped wires and fuse holder
14 iii.
iv.
v.