The text of a manual · part 2 of 4
Spectrum One Serial Access Bridge (SAB) II User's Guide, pages 4 to 13
Pages 4 to 13 of 31: Conventions; Contents; Chapter 1 System Overview
The original document is the PDF (634 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol SAB-2070 Access Bridge II
Page 4
Conventions Keystrokes are indicated with the angle brackets as follows: ENTER ALT+X BKSP, SHIFT, ON identifies a key. identifies a simultaneous key combination. identifies a key sequence.
Typeface conventions used include. [brackets] Italics Screen indicates available command line parameters options or in INI files as separators for configuration options. indicates first time a new term is used, a book title, information that must be replaced by an actual value, and menu titles. indicates monitor or terminal screen dialog. Also indicates user input.
Notes, Cautions and Warnings This manual uses notes, cautions and warnings for certain conditions or types of information. Note: Indicates tips or special requirements.
CAUTION Indicates conditions that can cause equipment damage or data loss.
Warning: Warnings indicate procedures that are potentially dangerous and should therefore be performed only by Symbol-authorized repair personnel.
Page 5
Contents Chapter 1. System Overview Remote Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Spectrum One Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Serial Access Bridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 Radio Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Transceiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-6 Cradle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Printers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7 Chipping Seed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-7
Chapter 2. Installation and Configuration Host Connectivity Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 Installation Outline. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Site Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 SAB Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 Component Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6 Hardware Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7 Cradle Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8 Host Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9 Primary Transceiver Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10 Power Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11 Audible Status Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
Appendix A. Software Development
Page 6
Chapter 1
System Overview The Serial Access Bridge (SAB) and the Spectrum One network provide your facility with wireless data collection abilities. Data collected from wireless terminals can be processed by a host computer connected to the SAB. Symbol Customer Support Services provides remote support for network management, software updates, and system diagnostics.
Figure 1 - 1. Serial Access Bridge II
1-1
Page 7
SAB II - User’s Guide
This environment allows host application development for managing data from terminals. Host applications are developed using our productivity programming tools or developing your own custom tools. For more information on programming the SAB, refer to the SAB Programmer’s Reference Manual.
Remote Maintenance The SAB modem connection allows remote systems to perform network maintenance and diagnostics routines. The remote viewing system connects to the SAB modem through telephone lines or null-modem.
Spectrum One Network The Spectrum One network provides rapid response communication between a host and many remote terminals over a large area. The Spectrum One network uses spread-spectrum radio technology. This technology was originally developed for military communication and is highly resistant to interception. Spread-spectrum allows radios to spread multiple signals across a Federal Communication Commission (FCC) approved range for commercial users. The result is that no FCC licenses are required. Radios used in terminals and transceivers are direct sequence spread-spectrum and operate within the approved bandwidth (902MHz to 928MHz). The Spectrum One network uses 49-frequencies (channels) within the spread-spectrum bandwidth. Radio channels are software selectable and each channel uses an approximate 1MHz at -20dB bandwidth. Physical devices in the Spectrum One network include: • one SAB • 1 to 16 transceivers • 1 to 40 radio terminals (LRT 3800, PRC 3310, VRC 3910, PDT 3110, APS 3395) • 1 to 24 terminal cradle slots (Models 3860 and 3866) • optional printers.
1-2
Page 8
System Overview
Serial Access Bridge Upon power up, the SAB operates without operator intervention as a gateway to the Spectrum One network. The SAB provides the connection between the Spectrum One network and the host through a serial link. The host is any mainframe computer, mini-computer, workstation, or PC supporting the Symbol serial packet protocol and communicating via the SAB. The SAB controls all input and output between the host and the Spectrum One network. The host recognizes each terminal logically with a unique number. The SAB software manages the Spectrum One network and maintains a logical connection with each network device. Terminals communicate with the SAB through a radio link with a connected transceiver or a serial-linked cradle. This allows terminals to communicate with the host and use host applications. The SAB requires a set of host applications to facilitate data interchange. Terminal applications typically involve data entry and queries to the host. Host applications provide responsive access for terminals. The SAB supports remote system administration, an optional service for SAB maintenance and diagnostic functions. System administration is achieved through an enabler on the host side or through Symbol Customer Support Services. Contact a Symbol service representative for more information.
1-3
Page 9
SAB II - User’s Guide
RS-232C, - :
| Gable i - - : Coaxial ;
Modem ; Cable | | i | RS-232¢ |
! Serial |
/ Cable : Modem | : Transceivers
Antenna
Symbol : Customer | = : Support | peessscseses | Services : Cradle !
Figure 1 - 2. Serial Link and Spectrum One Network
1-4
Page 10
System Overview
Hardware SAB components are: One RS-422 serial port connects to primary transceivers. Refer to 3850 Transceiver Quick Reference Guide.
Two RS-232-C serial ports connects to cradle and the host. Verify that the host has a compatible serial interface.
One RJ-11 modem phone jack for remote communication or local null-modem operation.
3-1/2", 1.44Mb floppy disk drive SAB software diskette version 3.01 is always installed in drive during normal operation.
Software The SAB software: • provides the functional interface between the host and Spectrum One network • manages Spectrum One topology. Refer to the SAB Programmer’s Reference Guide. • boots up and initializes SAB • performs orderly system shutdown and restart • downloads applications from host into terminals • routes application data to and from terminals • supports transceivers and cradles • optionally routes internal messages to host through bridge access routines (BARs). The SAB software is supplied on the 3-1/2" floppy disk included with the system. Note: Make a backup copy of the SAB software diskette before installation. Use the backup copy of the SAB software for configuration and operation. The main files are: SSP.EXE
SAB server program (SSP).
SSP.INI
SSP configuration information.
1-5
Page 11
SAB II - User’s Guide
Spectrum One configuration information is managed and stored according to the availability of File Access BARs: File Access BARs enabled from SPEC1.CFG, a binary file created from SSP.INI information, on the host in a directory where the host looks for files.
File Access BARS disabled frequency sets and chipping seed are retrieved from SSP.INI. Unit ID for terminals is maintained by the primary transciever non-volatile memory (NVM).
Note: SPEC1.CFG takes precedence over information in SSP.INI.
Radio Terminal A terminal collects data in the Spectrum One network and communicates with transceivers through radio unit. An application running on the terminal is a client to the host application. Terminals also contain a serial communication port to interface with a cradle or for communication to a printer.
Transceiver The transceiver has an interface to a coaxial bus for transceiver-to-transceiver communication and a serial interface for communication with the SAB. Transceivers have radios for routing data received from terminals. Transceivers send data to the SAB and pass responses from the SAB back to the terminals. As terminals migrate through different areas, they are handed-off between transceivers. This allows the terminal freedom to move over the entire network area.
1-6
Page 12
System Overview
Cradle The cradle provides: • direct serial communication • battery charging • file transfer and initial program download • new terminal configuration. The cradle connects to the SAB though a full-duplex serial link which passes data between the SAB and terminals in the cradle. Direct serial communication is provided via the optical interface between terminal and cradle. Cradles can be daisy chained on a single channel.
Printers Spectrum One devices support various printers. For more information, refer to the Series 3000 System Software Manual and the Series 3000 STEP Application Programmer’s Guide.
Chipping Seed The user-defined chipping seed generates a pseudo-random chipping sequence. The transmitter and receiver have the same chipping sequence. Superimposing data with the chipping sequence causes information to spread over the frequency band. Data sent over the airwaves is only intelligible to the receiver. The signal has high noise immunity.
1-7
Page 13
SAB II - User’s Guide
PAGE INTENTIONALLY BLANK
1-8