The text of a manual · part 2 of 2
RS 2200/3200 Series RF Modem 3010 Quick Reference, pages 11 to 20
Pages 11 to 20 of 20
The original document is the PDF (373 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol RFM-3010
Page 11
Charging the Battery Pack To charge the NiCad battery pack using an AC adapter:
1. Power off the RFM 3010.
2. Plug the power plug end of the cable into the AC power jack port on the RFM 3010. Plug the wall cube into the outlet.
3. If the RFM 3010 is not going to be used while it is charging, leave the power off while charging. Otherwise, power the RFM 3010 on and continue using.
The RFM 3010 will be fully recharged in 8 to 10 hours.
To recharge the battery pack outside of the RFM 3010, use the Symbol Universal Battery Charger. Using this charger, up to four NiCad packs can be charged at one time.
Page 12
10
Power On and Off
To turn the RFM 3010 on or off, press the Power button:
Com 1 Radio Com2 Prog. Aux. Power oOo O CO OO O a) O®
Forcing Power Off
If pressing Power does not turn the terminal off, you should force the power off. This reduces battery drain and preserves your data.
To force power off, press and hold Power for 20 seconds, until the terminal powers off.
Do not attempt to turn on and continue using the terminal. Return the terminal to your system administrator to recover any data and correct the problem.
Quick Reference
Page 13
11
Attaching a Scanner To attach a scanner to the RFM 3010:
1. Power off the RFM 3010.
2. Remove the rubber cover from the top of the RF Modem 3010.
3. Plugin the scanner. Make sure the plug is inserted firmly.
& oa NY
Note
Tf you will only be using the DE-9 port on the top of the RFM 3010, you may cut the rubber cover along the seam in the middle, and discard the section of the cover which covers the DE-9 scanner port. Similarly, if you mill only be using the RJ-41 port and not the DE-9 port, you may cut the rubber cover along the seam in the middle, and discard the section of the cover which covers the RJ-41 port.
Page 14
12
Using a Laser Scanner Note:
The LS 7000 scanner may not be used with this modem.
1. Power on the system and the scanner by pressing Power or pulling the scanner trigger.
2. Point the laser scanner at the bar code. Pull the trigger and adjust the aim so the red laser beam covers the entire bar code.
Note:
For the optimal scanning distance of a detachable scanner, consult the scanner operator's manual.
Quick Reference
Page 15
13
Using A Contact Wand Scanner
1. Press Power to power on the terminal.
2. Holding the wand at a 90 to 45 degree angle, lightly touch the tip of the wand to bar code.
3. Draw the scanner smoothly and at a moderate speed across the entire bar code.
Page 16
14
LED Descriptions
LED | Description
COM1 | Indicates communications status on COM1.
Radio Indicates communication status on the radio.
COMZ2 | Indicates communication status on COM2.
Prog. Used during program download/ can be programmed.
Aux User-application defined.
Power | Indicates power and low battery power. See RFM 3010 Product Reference Manual for more details.
Key Descriptions
Key Description
Status If the RFM 3010 is not plugged into the wall charger, status of COM1, COM2, and radio can be obtained by pressing this key.This key is also used during boot sequences.
A User-application defined.
B Used for boot sequences, also user-application defined.
Power Used to power on and off the RFM 3010.
Quick Reference
Page 17
15
Troubleshooting Troubleshooting Chart Symptom | Possible Cause Suggested Action No power Battery pack is dead or] Replace or recharge indicator missing, or terminal is) battery. not plugged into the wall charger. REM 3010 Application program | Repeat download, reboot, does not was not downloaded | cold boot. respond when] successfully keys are pressed.
Scanner will not operate
Scanner connection is loose or disconnected
Reconnect scanner cable.
Scanner is broken.
Replace scannet.
Scanning head needs cleaning,
Clean scanner head.
Bar codes do not meet industry standards
Try scanning another bar code.
‘Time and date ate incorrect.
Real-time clock needs to be reset.
Refer to the Series 3000 Application Programmer’s Reference Manual (p/n 59045-00- 93) for additional information.
Page 18
16
Symbol Support Centers
In the U.S.A, for service information, warranty information or technical assistance call:
SYMBOL SUPPORT CENTER 1-800-653-5350
If you purchased your Symbol product from a Symbol Business Partner, contact that Business Partner for service.
Canada Mississauga, Ontario
Canadian Headquarters (905) 629-7226
Europe Wokingham, England
European Headquarters
734-771-222 (Inside UK)
011-44-734-771222 (Outside UK) Japan
Tokyo
Olympus Symbol, Inc.
011-81-3-3348-0211
Quick Reference
Page 19
17
Notes
Page 20
Patents This product is covered by one or more of the following U.S. and foreign Patents: U.S. Patent No.4,360,798; 4,369,361; 4,387,297; 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156; 4,652,750; 4,673,805; 4,736,095; 4,758,717; 4,816,660; 4,845,350; 4,896,026; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,765; 5,021,641; 5,029,183; 5,047,617; 5,103,461; 5,113,445; 5,130,520 5,140,144; 5,142,550; 5,149,950; 5,157,687; 5,168,148; 5,168,149; 5,180,904; 5,229,591; 5,230,088; 5,235,167; 5,243,655; 5,247,162; 5,250,791; 5,250,792; 5,262,627; 5,262,628; 5,266,787; 5,278,398; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,788; 5,306,900; 5,321,246; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,053; 5,396,055; 5,399,846; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,411; 5,436,440; 5,444,231; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,000; 5,479,002; 5,479,441; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,889; 5,552,592; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,531; 5,619,028; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,835; 5,705,800; 5,714,746; 5,723,851; 5,734,152; 5,734,153; 5,745,794; 5,754,587; 5,762,516; 5,763,863; 5,767,500; 5,789,728; 5,808,287; 5,811,785; 5,811,787; 5,815,811; 5,821,519; 5,821,520; 5,823,812; 5,828,050; 5,850,078; D305,885; D341,584; D344,501; D359,483; D362,453; D363,700; D363,918; D370,478; D383,124; D391,250. Invention No. 55,358; 62,539; 69,060; 69,187 (Taiwan); No. 1,601,796; 1,907,875; 1,955,269 (Japan). European Patent 367,299; 414,281; 367,300; 367,298; UK 2,072,832; France 81/ 03938; Italy 1,138,713. rev. 1/99
:30453:8034# 5HYLVLRQ#%#³#$SULO#4<<<