Page 187

Chapter 10 Troubleshooting Chapter Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3 Power a Terminal On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-3 System Configuration Utility (SCU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-5 Switches on the Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-6 Troubleshooting a PPT 4300 Series Terminal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-7 Beep Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-13 Diagnostic Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-14 Bypassing and Debugging config.sys and autoexec.bat . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-14 Network Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-14 RF/AP Diagnostic Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-17 Troubleshooting RF Interference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-19 Terminal Emulators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-20 Keyboard Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-20 Status Line Warning Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-20 Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-21 Citrix ICA Client for DOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-26 Frozen Sessions and Disconnections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-26 TCP Error Messages Under Citrix ICA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-26

10-1

Page 188

PPT 4300 Series Product Reference Guide

10-2

Page 189

Troubleshooting

Overview This chapter describes solutions to problems that may occur when users are working with a PPT 4300 series terminal. It includes information on network troubleshooting, radio interference, effective range and the warning messages that appear if you lose connection with the network. It also describes the diagnostic utilities and the error messages for the Terminal Emulators and Citrix ICA.

Power a Terminal On If you have trouble starting a PPT 4300 series terminal, follow these instructions. Begin with step one. If the terminal does not start after step one, continue to step two, and so on. Stop following the instructions once the terminal starts. If the terminal starts but does not seem to be functioning properly, see Troubleshooting a PPT 4300 Series Terminal on page 10-7. Also see Switches on the Terminal on page 10-6. 1. Power the terminal on by using the Power icon on the Direct Access panel: a. Set the Run/Ship switch to Run (see Figure 10-2). b. Insert a fully charged battery pack or connect a DC adapter. c. Press the pen against the Power icon for one full second (see Figure 10-1). Listen for start-up beeps and watch for text to appear on the screen. Power Icon DC Adapter Direct Access Panel

Function Keys DC Adapter Connector

•

Force On Switch

Figure 10-1. Starting a PPT 4300 terminal 2. If the terminal does not power up after step one, press the Force On switch for one full second (see Figure 10-1). Listen for start-up beeps and watch for text to appear on the screen.

10-3

Page 190

PPT 4300 Series Product Reference Guide

3. If the terminal does not power up after step two, try the Master Reset switch: a. Place the terminal face down and gently pry off the left rubber foot. b. Press the Master Reset switch for one full second (see Figure 10-2). Listen for start-up beeps and watch for text to appear on the screen. 4. If the terminal does not power up after step three, try pressing the Force On and Master Reset switches in this combination: a. Press and hold the Force On switch. b. While still holding the Force On switch, press and hold the Master Reset switch for one full second and then release it. c. Release the Force On switch. Listen for start-up beeps and watch for text to appear on the screen 5. If the terminal still does not power up after step four, you must remove all power to the circuits by sliding the CMOS battery switch to the off position before starting. a. Remove the battery pack and external DC adapter. b. Slide the CMOS battery switch to the OFF position (see Figure 10-2). c. Wait 30 seconds. d. Insert a fully charged battery pack or external DC adapter. e. Press the Master Reset switch for one full second. Listen for start-up beeps and watch for text to appear on the screen. You will need to run the System Configuration Utility. See System Configuration Utility on page 10-5. f. When the terminal boots normally, slide the CMOS Battery switch to the ON position. Master Reset Switch

Run/Ship Switch

H CMOS Battery Switch ↑ Off ↓ On

H

H

Left Rubber Foot

Figure 10-2. Switch Locations

10-4

Page 191

Troubleshooting

Note: If you think the terminal is running but the screen is completely black or white, with no text visible, try changing the contrast. Hold down the <Fn> key and press <F9> to darken or <F10> to lighten the screen until the text appears. You may have to press the <Fn> key combination 50 times or more to make the display visible.

System Configuration Utility (SCU) When the terminal starts, it may halt at the first screen with this message: WARNING - CMOS FAILURE - RUN SCU CTRL-ALT-S to enter System Configuration Utility. Press F1 to Continue

This means the CMOS is either corrupt or uninitialized. To reset the CMOS: 1. Press <Ctrl-Alt-S> to open the System Configuration Utility (SCU). 2. Do not change anything. 3. Press <Esc> and then press <Enter>. The terminal should reboot normally. You will need to configure it at the Control Panel (see Chapter 4, Standard Terminal Configuration). 4. If you have a terminal with a flash expansion module (model PPT 43xx-xxxWxx), you must go back into the SCU and set the Flash size: a. Watch the text on the display screen as the terminal boots. b. When prompted, press <Ctrl-Alt-S> to open the SCU. c. Open the Flash File menu and select Set Flash File System Size. d. Set the flash to the size of the first internal partition of the terminal’s internal flash file system (e.g., 2 MB). e. Press <Esc> and then press <Enter> to reboot the terminal. f. Configure the terminal at the Control Panel (see Chapter 4, Standard Terminal Configuration). Edit any settings that may have been reset. If you change Control Panel settings during configuration, copy and store the settings in a safe location. Note: A fully charged swap battery will maintain the CMOS parameters for at least 30 days in Ship mode. If the swap battery was not fully charged when the terminal was shelved, or if it was in Run mode, then the CMOS parameters can be lost in less than 30 days.

10-5

Page 192

PPT 4300 Series Product Reference Guide

Switches on the Terminal <Ctrl-Alt-Del> Press <Ctrl-Alt-Del> to perform a soft boot of ROM-DOS.

Force On Use the Force On switch if the terminal has had a crash or abnormal shutdown, and then fails to turn on when the Power icon is pressed. You can reach it through a hole in the IRDA window on the right side of the terminal. Use a non-metallic item to gently press it and hold for one second. Normally, when a PPT 4300 series terminal powers off, it configures the Digitizer Panel to allow the terminal to power up when the Power icon area is pressed. If the terminal does not power off normally, this configuration may not occur (e.g., if ROM-DOS crashes abruptly). The Force On switch provides a direct turn-on signal to the circuitry, and starts the terminal. Note that the Force On switch does not turn the terminal off.

Run/Ship Switch This switch is normally used when storing or shipping a PPT 4300 series terminal. When set to Ship, the two swap batteries are changed from series to parallel connection, to increase the effective CMOS retention time. On PPT 4300-00R models only: You cannot start the terminal with the Power icon while the Run/Ship switch is set to Ship. In Ship mode, the digitizer is disabled to prevent the terminal from being turned on accidentally. Note: Do not use a metallic object to activate the Force On or Master Reset switches.The EM Pen tip does not fit into the opening for the Force On switch.

Master Reset Switch Use the Master Reset switch if the terminal refuses to power on or off. It is a last resort method. This push-button switch is located at the back of the terminal, under the left rubber “foot”. To use it, place the terminal screen side down, with the two long rubber feet in front of you. Gently pry off the left foot. To press the Master Reset switch, gently press a nonmetallic stick down into the upper ‘H’ cutout (closest to the Run/Ship switch) and hold for one second. See Figure 10-2 on page 10-4. 10-6

Page 193

Troubleshooting

Troubleshooting a PPT 4300 Series Terminal Table 10-1 describes some common terminal problems and what actions to take. Table 10-1. PPT 4300 Troubleshooting Symptom

Possible Cause

Terminal does not Terminal not powered on. power up: • no display • no keyboard Battery is not installed. backlight Battery is not charged.

Action Press the Power icon to start the terminal. If it does not start, see Terminal does not power up: on page 10-7. Make sure the battery is correctly placed in the terminal and the latch is fully extended. Make sure to use a charged battery.

Power supply is not plugged in. If you are using a DC Adapter, make sure it is connected properly to the terminal and plugged into a live power outlet. The digitizer is not initialized.

Press the Force On switch inside the IrDA port window.

Previous application crash or other abnormal shut-down.

Toggle the Run/Ship switch in the battery well. If this doesn’t work, use the Master Reset switch (described on page 10-6).

Bad CMOS values due to dead 1. Press and hold the Force On switch (see batteries. Figure 10-1). 2. While still holding the Force On switch, press the Master Reset switch for one full second and then release it (see Figure 102). 3. Release the Force On switch. Listen for start-up beeps and watch for text to appear on the screen. You may have to reset the CMOS using the SCU. See System Configuration Utility (SCU) on page 10-5. Battery Latch is stuck in the “up” position. The start-up beeps happen, but no lights come on.

Move the battery latch back and forth and then repeat the battery swap, making sure the Battery Latch moves down into place. Then use the Master Reset switch to restart the terminal (see Figure 10-2).

10-7

Page 194

PPT 4300 Series Product Reference Guide

Table 10-1. PPT 4300 Troubleshooting Symptom

Possible Cause

Action

Terminal does not PPT 4300-00R models only: power up the Run/Ship switch is set to Ship in the battery well. (continued from page 10-7).

Set the Run/Ship switch to Run.

Cannot see screen. Contrast or brightness not adjusted properly. • LEDs light up • keyboard backlight works

Press the brightness and contrast control icons on the Direct Access Panel or press <Fn-F9> and <Fn-F10> to adjust the contrast and press <Fn-F11> to adjust the brightness. If the brightness or contrast are set at an extreme, you may need to press these keys several dozen times.

Terminal is in Doze or Sleep mode.

Press the screen with the pen or press a key to reactivate the terminal.

Terminal does not Application crash or program turn off. failure.

Reset the terminal. Press <Ctrl-Alt-Del> to reboot, or you can press <Ctrl-Fn-F12> to power off immediately. You can also toggle the Run/Ship switch in the battery well. If these don’t work, use the Master Reset switch, as described on page 10-6.

Terminal does not The internal flash file system boot properly. and/or the BIOS may be corrupt.

Attempt to boot from the PPT 4300 Utilities PC card. If the terminal boots from the card, then the BIOS is likely to be OK but the Flash File System is corrupt. Reformat and sys the internal flash file system and then reload the software. See Formatting the Internal Flash File System on page 3-4. If the terminal will NOT boot from the Utilities card, then the BIOS is corrupt or Cardboot is not enabled. Return the terminal to Symbol Technologies for repair.

Message: The CMOS is either corrupt or Reset the CMOS following the instructions uninitialized. in System Configuration Utility (SCU) on Floppy disk page 10-5. fault -insert valid boot disk and press any key.

10-8

Page 195

Troubleshooting

Table 10-1. PPT 4300 Troubleshooting Symptom

Possible Cause

Boot files are either corrupt or System Not missing. The internal flash file Found appears when the terminal system may need to be rebuilt. boots.

Message: WARNING - CMOS FAILURE - RUN SCU CTRL-ALT-S to enter System Configuration Utility. Press F1 to Continue

Action Boot from the PPT 4300 Utilities PC Card and inspect the internal flash file system. Depending on which files may have been damaged, you may need to reinstall boot files using sys.com, or reformat the internal flash file system, as described on page 3-4.

This message may appear after Reset the CMOS following the instructions a reset or a crash. It means that in System Configuration Utility (SCU) on the checksum is incorrect and page 10-5. you may have lost the CMOS settings You may also lose CMOS settings if you store a terminal with no battery for longer than 30 days.

After Card Trick \ibmbio.com and \ibmdos and Cardboot are missing or damaged. load, screen goes blank, with blinking cursor in upper left corner.

Boot from the PPT 4300 Utilities PC Card. Exit to a DOS prompt, and run sys d: to install boot files. If this fails, the internal flash file system may need to be reformatted, as described on page 3-3.

Battery warnings Terminal is “dozing” due to Power Management. and low battery light not working. Battery Warnings are disabled in ppt4300.ini or in the Control Panel.

“Wake” the terminal by pressing the screen with the pen.

System function driver not loaded.

Check the settings in ppt4300.ini or the Control Panel (see Settings in ppt4300.ini on page 7-4 or Battery Options on page 6-15 for details). Boot to a DOS prompt and verify that the sftsr driver (sftsr.com) is loaded when the terminal starts. Make sure that autoexec.bat includes these lines in the :driver area: sftsr sfinit

10-9

Page 196

PPT 4300 Series Product Reference Guide

Table 10-1. PPT 4300 Troubleshooting Symptom Terminal powers off when you try to do a Battery Swap.

Battery charger not re-charging batteries.

Possible Cause

Action

Swap battery doesn’t have Recharge the swap batteries (see Batteries enough charge to maintain the and Power on page 5-14). session during a Battery Swap. Note: The host may disconnect the session after 10 seconds. The terminal automatically powers off if it is left running on the swap battery for more than 45 seconds. Run/Ship switch is set to Ship.

Set the Run/Ship switch to Run so that the swap batteries will charge during normal use, and allow you to do a battery swap (see Batteries and Power on page 5-13).

Battery packs inserted incorrectly into the Battery Charger.

Make sure each battery pack is being inserted correctly. See the documentation for your Battery Charger for more information.

Charger is not working.

Try a number of different batteries in the same battery charger slot. If none of the battery packs will charge, and you are inserting the packs correctly, then the charger slot may not be working properly. Also try inserting the battery pack into different chargers. If the pack charges when placed in a different charger, then the battery charger slot may be faulty. If a battery does not charge in any battery charger, then the battery pack is faulty.

Battery pack is faulty.

Battery voltage is so low that Place the battery in a terminal powered by a the charger assumes the battery DC adapter to trickle charge for a few hours. is defective. Then retry in the Battery Charger. Battery life too Battery not fully charged. short (less than 4 hours of active use). Battery is old.

10-10

Replace the battery with a fully charged battery. Run the faulty battery through a conditioning cycle in the Battery Charger. After a battery has been recharged 500- 600 times, it may be past its useful life. Run the battery through a conditioning cycle in the Battery Charger, or replace the old battery with a new battery. See Conditioning Batteries on page 9-6.