Page 111

Operation

Changing the Main Battery The terminal includes a small swap battery that maintains power to the terminal while you change the battery pack. To change the battery pack on a PPT 4300 series terminal without logging out or losing your session: 1. Make sure you have a fully charged battery pack available and close at hand. 2. Hold the terminal so that the back of it is facing you, but do not rest it on a table. The table may cause keys to be pressed, causing input to an application. 3. Firmly push up on the Battery Latch. The Ejector Spring pushes the battery up. 4. Slide the discharged battery pack out of the compartment. The terminal enters a Swap mode as soon as you remove the battery. Swap mode is similar to Sleep mode, but the CPU stays active. The swap battery maintains power to the terminal for up to 30 seconds, while you insert a fully charged battery. If you fail to insert a new battery within 30 seconds, the terminal powers off. 5. Place the bottom of the fully charged battery pack into the battery well. The tabs at the bottom of the battery fit into two slots at the bottom of the battery well. 6. Push the top into place until the battery latch clicks into place. Make sure the latch spring is all the way down, or the terminal will not be able to use the battery. Note: These instructions assume that the terminal’s swap battery has enough capacity to sustain a 30-second swap operation. For the first two to three days with a new terminal, end your session and power the terminal off before you change the battery. This break-in period allows the swap battery to acquire a full charge.

Battery Latch Ejector Spring

Battery Contacts

Battery Well

Figure 5-7. Parts of the Battery 5-17

Page 112

PPT 4300 Series Product Reference Guide

Using an External Power Supply As an alternative to using battery power, you can connect a PPT 4300 series terminal to an 18V DC adapter and plug it into a standard North American electrical outlet. Power Management features are disabled while the DC adapter is supplying power. To connect power to the terminal through a DC adapter: 1. Plug the DC adapter into the DC Port on the right side of the terminal. 2. Plug the other end of the adapter into an electrical outlet. " The Run/Ship switch must be set to Run. " The DC adapter will trickle charge a battery pack at about 1% an hour if the terminal is on, or 2% an hour if the terminal is off.

Figure 5-8. Connecting External Power to the Terminal Note: Use only a Symbol-approved adapter, and leave a battery pack in place while you are using the terminal with external power. Make sure to use the correct adapter for the terminal. Using a different adapter (e.g., The 24V DC Adapter for the Battery Charger) will damage the terminal’s circuitry. Contact your Symbol Representative for information on adapters for use outside of North America.

5-18

Page 113

Operation

Power Management Modes PPT 4300 series terminals support Power Management modes that extend the period of time the terminal can run on a single battery. When the terminal is on, but is not in active use (this means no input from keypad or pen), it uses these modes to decrease the drain on the battery. Table 5-3 defines the Power Management modes. You can enable or disable Power Management modes at the Control Panel. For more information, see Power Options on page 6-12. Table 5-3. Power Management Modes Power Management Mode

Description

Run

The terminal is in full active use, with all components working at full power. After 17–76 seconds of inactivity (no input from keyboard or pen), the terminal enters Doze mode. Use the Control Panel to configure the amount of time before the terminal enters Doze mode.

Doze

In Doze mode, the CPU slows or stops, depending on the Stop CPU Clocks during Power Management setting at the Control Panel. The screen backlight dims and, if the CPU is stopped, the screen freezes. The session resumes as soon as you use the keyboard or pen. The terminal stays in Doze mode from 4 seconds up to 17 minutes, depending on the Control Panel setting. Then it enters Sleep mode. The terminal can maintain power to the radio during Doze and Sleep modes, but if the CPU is stopped, it suspends communication with the host. As a result the host may disconnect your session. If this occurs, you must log in again. To avoid such disconnects, deselect the Stop CPU Clocks during Power Management option, or consider disabling the Run–Doze transition. Note: if you disable the Run–Doze transition, the lower transitions are also disabled (Doze–Sleep).

Sleep

In Sleep mode, the CPU slows or stops, depending on the Stop CPU Clocks during Power Management setting. The screen backlight turns off and, if the CPU is stopped, the screen freezes. When you use the keyboard or pen the session resumes. The terminal stays in Sleep mode for 1 to 272 minutes and then powers off, depending on the Control Panel setting. To force the terminal into Sleep mode, if the Power icon has been configured for this, press the Power icon or press <Fn-F4>. See Settings in ppt4300.ini on page 7-4.

Off

After 1 to 272 minutes in Sleep mode, the terminal powers off, and must be re-booted. While the terminal is off, only the CMOS memory and digitizer panel controller maintain power.

5-19

Page 114

PPT 4300 Series Product Reference Guide

Scanning Operating a Scanning Terminal The PPT 4300-S0E provides an integrated SE 1223 scanning module, with 1-D standard capability. The scanner is configured for level (triggered) mode. You can configure other modes by using configuration bar codes. For the configuration bar codes and further information about configuring the scanner, contact your Symbol support representative.

Scanner window

Figure 5-9. The Integrated Scanner on a PPT 4300-S0E

Caution The SE 1223 scanner engine is a Class 2 laser scanner. It uses a low power, visible light diode. As with any very bright light source, the user should avoid staring directly into the laser beam. Momentary exposure to a Class 2 laser is not known to be harmful. Note: The scanner should decode properly printed bar codes quickly and effortlessly. Contact the Symbol Support Center if you have difficulty scanning.

5-20

Page 115

Operation

Using the Scanner The terminal must be running a scanning application and scanner driver before anyone can use the scanner. To use the integrated scanner in level (triggered) mode: 1. Make sure that the terminal is on and the screen display is active. 2. An application must be running, and in a state that allows scanning. 3. Hold the scanner approximately 6–18 inches (15–45 cm) from the bar code. Aim the scanner window at the bar code. 4. Press a Scan button on the back of the terminal, or press the Scan icon with the pen. See Figure 1-2 on page 1-6 for location of the buttons and icons. 5. Adjust the aim of the thin, red laser beam to cover the entire length of the bar code:

Wrong

Right

The red laser beam stays lit while the bar code is being decoded. If decoding is not successful, the scanner turns off after approximately 3 seconds. 6. If the decode is successful, data appears on the screen. Note: On terminals with radios, the scanner locks out radio transmission for up to three seconds during the scan. This should not affect your session with a host computer; most communications systems will tolerate occasional brief interruptions like this.

Scanning Tips Scanning is usually a matter of aiming, scanning, and decoding. It is generally mastered simply and intuitively after a few quick test scans. Two important considerations can optimize any scanning technique, range and angle.

Range The best scanning range depends on a bar code’s size and density, but most combinations work at a distance of about 12 inches (31 cm). In general: !

Hold the scanner farther away for larger symbols.

!

Move the scanner closer for symbols with bars that are close together.

5-21

Page 116

PPT 4300 Series Product Reference Guide

!

Start scanning at a distance from the bar code, not from direct contact. If the bar code does not readily decode, move the scanner closer.

The best way to specify an appropriate working range is through a chart called a Decode Zone (see Appendix E, PPT 4300 With Integrated Scanner (PPT 4300-S0E)). A decode zone plots working range as a function of minimum element widths of bar code symbols.

Angle The scanning angle is important for quick bar code decoding. If you scan at the wrong angle, or place the scan window directly over the bar code, the laser light will reflect directly back into the scan window from the bar code. This is known as specular reflection. Specular reflection can “blind” the scanner and make decoding difficult. For the scanner to successfully decode: !

Hold the unit directly in front of the bar code at a slight angle (no more than 30°).

!

Do not scan at a sharp angle or the decode will not be successful.

!

Practice several test scans to find the best angle.

Figure 5-10. Scanning a Bar Code

Scanning and Power Management Modes If the terminal is in Doze or Sleep mode, pressing a Scanner button will not return the terminal to Normal mode. To return to Normal mode: !

Press a key on the keyboard.

!

Press the pen anywhere on the display. Note: If the terminal is in Doze or Sleep mode, pressing the Scan icon on the Direct Access panel returns the terminal to Normal mode but does not activate the scanner. You must press the icon a second time to scan.

5-22

Page 117

Operation

Using an External Bar Code Scanner PPT 4300 series terminals support external bar code scanners for use with applications in Citrix ICA and Metaframe, DOS and the Terminal Emulators. The two options described here apply to external, tethered scanners only and not to integrated scanners. PPT 4300 Series Terminal

Tethered Scanner

Symbol Synapse Smart Cable

Figure 5-11. Using a Tethered Scanner from the External Keyboard Port

Scanning from the External Keyboard Port This solution for bar code scanning works from Citrix ICA, DOS and Terminal Emulator applications. The scanner plugs into the external keyboard port and functions similarly to an integrated scanner. You need: !

a Symbol Synapse Smart Cable

!

any PPT 4300-00E series terminal with a serial number starting with M02 or a PPT 4300-S0E terminal.

!

a tethered, compatible scanner (e.g., the LS4004 scanner)

The Smart Cable plugs into the keyboard port, and the scanner plugs into the Smart Cable. You do not need kbwedge.com or other special software. The scanner, also known as a “wedging” scanner, functions with any application that accepts input from the keyboard data stream. Contact Symbol Technical Support for information on compatible scanners. Note that the PPT 4300-00R and earlier versions of the PPT 4300-00E are not voltagecompatible with the Symbol Synapse Smart Cable.

Scanning from the Serial Port This solution works with DOS, Terminal Emulator and Citrix applications. The scanner plugs into the RS232 serial port. The serial port is activated by the scanner.com program, which causes the terminal to supply power to the scanner. You need: ! !

a tethered, decoded scanner (e.g., the LT1820 scanner) a PPT 4300 serial adapter cable 5-23

Page 118

PPT 4300 Series Product Reference Guide the scanner.com utility for configuring the serial port for use with a scanner keyboard wedge software (kbwedge.com) for inserting scanner data into the keyboard data stream The scanner.com and kbwedge.com software are available from Symbol. To use the serial port (COM1) for scanning, you must activate COM1 for RS232 mode, and load the keyboard wedge. ! !

To activate COM1 in scanner mode (RS232 mode with +5V power on the RI pin): 1. Install the scanner.com file onto the terminal in C:\bin. 2. Type scanner at the DOS prompt and press <Enter>. To load the keyboard wedge: 1. Install the kbwedge.com file onto the terminal in C:\bin. 2. To redirect the data to the keyboard buffer (as is done when using the internal scanner, or a wedging tethered scanner), you must run kbwedge as follows: C:\>kbwedge /COM=1

The “/COM=1” argument tells it to get the data from the serial port. 3. Plug the scanner into the RS232 Port. If you have any questions about tethered bar code scanning, or for information on compatible scanners, please contact Symbol Technical Support. Note: If you use a tethered scanner with a PPT 4300-S0E integrated scanner terminal, the kbwedge.com program will load on start up. The program cannot be loaded twice. Therefore, if you are using an external scanner, unload (kbwedge /unload) and then reload the program using the “/COM=1” argument.

The scanner.com Utility The scanner.com utility configures the serial port on a PPT 4300 series terminal to allow use with an external scanner. It enables the serial port (if it was disabled). It also provides +5V supply to the RI pin. You can run it more than once without causing problems. There are no command line parameters. If you don’t want +5V on the RI pin, use the rs232.com utility.

5-24