Page 103

Operation

Numeric Keypad The keypad incorporates a numeric keypad, using the symbols marked in small, colored symbols on the right side of the keypad. On North American keypads, the numeric keypad symbols appear on the 7, 8, 9, 0, U, I, O, P, J, K, L, ;, M, > and ? keys. To use the numeric keypad: 1. Press the <NumLock> key. When the <Numlock> key is on, the LED above it lights up. 2. To enter numbers, press and hold the <Fn> key, and then press keypad keys (e.g., <Fn-J> = 1). 3. You can also set the terminal into Quick Numeric Keypad Overlay mode, so that when <Numlock> is on, the numeric keypad works as a numeric keypad without the <Fn> key (e.g., J=1).

Using an External Keyboard The PPT 4300 has a port for connecting a Symbol-approved, low power PS/2-AT type keyboard. See Parts of the Terminal on page 1-6 for the location of this port. Do not use a keyboard that has not been approved for use by Symbol. Using unapproved keyboards may cause excessive power consumption and reduce battery life. Make sure you are using the correct keyboard for the type of terminal you have. PPT 430000R terminals provide 3.3V to the keyboard port. PPT 4300-00E and PPT 4300-S0E terminals provide 5V to the keyboard port.

5-9

Page 104

PPT 4300 Series Product Reference Guide

Direct Access Panel Icons The Direct Access Panel is a vertical row of icons located on the left side of the display window. It allows users to select from pre-defined options such as adjusting brightness and contrast, or displaying battery information. To select an item from the Direct Access Panel, press a Direct Access Panel icon firmly with the pen. Some of the Direct Access Panel icons have keyboard shortcuts - see Using the Keypad on page 5-8. Direct Access Panel options are available to all users. System Administrators can also adjust display and contrast settings at the Control Panel. For more information, see Chapter 6, The Control Panel. Note: Direct Access Panel icons only work if the sftsr.com, sfinit.com, and pen drivers (mutohpen.com or touch.com) have been loaded.

Power

Display

Contrast

Contrast

Battery

Mouse

Scan

Figure 5-3. Direct Access Panel Icons

5-10

Page 105

Operation

The Power Icon Power

The Power icon is the top icon on the Direct Access Panel, on the left side of the display.

If the terminal is off: The Power icon powers the terminal on. Press and hold the pen to the Power icon until you hear a three-note melodic beep. This indicates that the terminal is beginning to boot normally. You must wait for the terminal to finish booting before you can log in and use applications. If the melodic beep is followed by a harsher two-note sound, it means the battery is depleted. This “depleted battery” sound also occurs if a user ignores low battery warnings and the battery drops to less than 1% capacity (sound occurs as the terminal powers off). If there is no battery or power supply, there are no sounds when you press the Power icon. If the terminal does not power on, check the Run/Ship switch in the battery well. Also see Chapter 10, Troubleshooting. On PPT-4300-00R (Resistive Digitizer) terminals only: If the terminal is powered off, and something touches the display screen at a location other than the Power icon, the terminal emits a single repeating beep. If the screen continues to be pressed while in this mode, the terminal beeps 10 times and then disables the touch screen, including the Power icon. The terminal must then be powered on using the Force On switch.

If the terminal is on: By default, pressing the Power icon powers the terminal off. If you have been running a Terminal Emulation session, the status line prompts you to close your session before the terminal powers off. If you have been running a Citrix ICA client session, the terminal powers off. If you have not logged off, the host disconnects the terminal but leaves your session running for a period of time (time depends on host configuration). If you reconnect to the host during this time period, you can reconnect to the same session. You can change the default action of the Power icon so that it puts the terminal into Sleep mode instead of powering it off. To reactivate a sleeping terminal, press the pen on the screen or press a keypad key (e.g., Shift key). A pen or keystroke activates the terminal but does not affect any application that may be running on the terminal. System Administrators can use the Control Panel to set the length of time the terminal spends in Sleep mode before powering off, or to disable powering off from Sleep. For more information, see Power Management Modes on page 5-19 and Power Options on page 6-12. To change the default action of the Power icon, edit the Power tab settings in the Control Panel application. As an alternative, you can also edit the PowerIconOff and PowerIconPrompt values in the [PowerMgmt] section of the ppt4300.ini. See Settings in ppt4300.ini on page 7-4 for details.

5-11

Page 106

PPT 4300 Series Product Reference Guide

Settings To display a Settings window, press the Settings icon or press <Fn-F7>. The Settings window displays the terminal’s current settings, including: IP Address, Terminal Name, radio MAC address (if a radio driver is loaded), Date, Time and serial number. If the RF/AP Diagnostic tool has been enabled, a checkbox appears on the settings pop-up. To run this tool, select the checkbox. See page 10-17 for more information on the RF/AP Diagnostic tool.

Figure 5-4. The Settings Pop-up Window You can also use the Settings icon to run the Control Panel. To run the Control Panel, press the Settings icon when prompted, while the terminal is booting. For more information on the Control Panel application, see Chapter 6, The Control Panel.

Brightness The terminal has three brightness levels, set at the Display tab of the Control Panel. To cycle through the available brightness levels, press the Display icon or press <Fn-F11>. See Display Options on page 6-6 for information on using the Control Panel to set intensities for the brightness levels.

Contrast To increase (darken) screen contrast, press the Contrast (+) icon or press <Fn-F9>. To decrease (lighten) screen contrast, press the Contrast (-) icon or press <Fn-F10>. The terminal retains its contrast settings when you shut it off. See Display Options on page 6-6 for information on using the Control Panel to set the contrast level.

5-12

Page 107

Operation

Battery

Battery Level

To display the Battery Status window, press the Battery icon or press <Fn-F2>. It shows the current battery capacity and the Warning and Critical limits. The Control Panel provides more detailed battery information. See Battery Options on page 6-15 for more information.

Figure 5-5. Battery Status Pop-up Window

Mouse Setting (PPT 4300-00R only) By default, pressing the display with the pen acts as a left mouse click. On PPT 4300-00E and PPT 4300-S0E models, users can right click by pressing and holding the button on the side of the Electromagnetic pen as they press the screen. On these models, the Mouse icon is disabled. You can use the Control Panel to set a right click to be the default pen action. See Default Mouse Click on page 6-8 for details. For Terminal Emulator applications, if you do not wish to use the right-click action, you can alter it by setting the RightEqualsLeft parameter in ppt4300.ini (see Settings in ppt4300.ini on page 7-4). The Mouse icon allows you to perform a right click or right double click on a PPT 4300-00R. To perform a right click on this model, select the Mouse icon; the next pen action acts as a right mouse click. After one right click or double click, the pen action reverts back to a left click.

Scan (PPT 4300-S0E only) This icon is only active on PPT 4300-S0E terminals. To perform a scan, press the icon with the pen while you are using an application that accepts scanned data. You may also trigger a scan by pressing one of the Scan buttons located on the back of the terminal. See Scanning on page 5-20 for more information on scanning from a PPT 4300-S0E terminal.

5-13

Page 108

PPT 4300 Series Product Reference Guide

Batteries and Power A PPT 4300 series terminal runs on a rechargeable NiMH (Nickel Metal Hydride) battery pack using Smart Battery technology. A fully charged battery pack lasts for four to five hours of active use, with Power Management disabled. The terminal’s Power Management features can extend this time significantly. To run a terminal for extended periods without a battery, use a Symbol-supplied 18V DC Adapter plugged into a standard North American electrical outlet. PPT 4300 series terminals also have an internal battery known as a Swap battery. It provides limited power to essential circuits while the main battery pack is being replaced (or “swapped”). It also maintains power to the CMOS memory. It is not user-accessible. This section describes: !

Smart Battery features

!

the internal swap battery

!

the battery warning messages

!

how to check the battery level

!

how to change and recharge batteries

!

Power Management features Note: To prevent damage to the battery well, always leave a battery pack in the terminal, except when shipping or storing the terminal for more than a week. If you are shipping or storing the terminal, remove the battery and set the Run/Ship switch to Ship to maximize CMOS memory retention time. See Figure 1-2 in Chapter 1.

Smart Battery Information The terminal uses NiMH batteries containing a “smart” battery chip. This chip monitors the information listed below, and sends the information to the terminal. To view battery information, display the Battery tab of the Control Panel (described in Battery Options on page 6-15). The Smart Battery monitors this information: ! ! ! !

5-14

Battery Serial Number Date of manufacture (Last Service Date) Original (nominal) maximum battery capacity Current capacity

Page 109

Operation

Swap Battery The swap battery is a small internal NiCd battery that maintains CMOS settings when there is no main battery. It also allows you to change a battery pack without switching the terminal off. When you remove the main battery, the swap battery maintains your session for up to 30 seconds while you change the battery pack. The terminal automatically powers off if it is left running on the swap battery for more than 30 seconds, with no attempt to close user applications or sessions in progress.

Charging the Swap Battery The swap battery recharges itself from either the main battery or from AC power, regardless of whether the terminal is on or off. !

After a single, 30-second swap, the swap battery needs about 1 hour to recharge. The main battery fast charges the swap battery.

!

A swap battery that has been completely depleted (e.g., if the terminal has been sitting unused for a number of weeks) may take up to 10–16 hours to fully recharge.

If the swap battery has not had enough time to recharge, the terminal may turn off when you try to perform a battery swap. Note: The swap battery in a new PPT 4300 series terminal requires a breakin period of two to three days. If you attempt to use the swap batteries during the break-in period, the terminal may turn off abruptly and you may lose your session. Before you change battery packs during the break-in period, either: # log out of your session and power the terminal off, or # connect the terminal to AC power.

Battery Warning Messages When battery capacity drops to low levels, the terminal provides pop-up warning messages and the low battery light flashes. There are a number of Control Panel options that control when and how the warning messages appear. See Battery Options on page 6-15 for details. Note that sftsr.com and sfinit.com must be loaded for the Battery Warnings to operate. The pop-up battery warnings can be disabled in ppt4300.ini (see Settings in ppt4300.ini on page 7-4), but the low battery light still flashes. When a battery warning message appears, either change the battery, or end your session and power the terminal off.

5-15

Page 110

PPT 4300 Series Product Reference Guide

You can change the timing of the battery warning messages at the Battery tab of the Control Panel (at what percentage of battery capacity they appear, and how long they appear and disappear). By default, the Low warning window appears when battery capacity falls to 8%. At 8% of battery capacity, you have about 19 minutes of active battery life left. The Low warning popup window is framed in yellow. It appears for 8 seconds, disappears, and then reappears 15 seconds later. This continues until you press <Enter> or the OK button to acknowledge it. By default, the Critical warning window appears when battery capacity falls to 4%. At 4% of battery capacity, you have less than 10 minutes of active battery life left. The Critical warning pop-up window is framed in red. It appears for 8 seconds, disappears, and then reappears 15 seconds later. This continues until you press <Enter> or the OK button to acknowledge it. If battery capacity falls below 1%, the terminal may power itself off abruptly at any time. If you had an active session with the host and the terminal turns off, your session will be abruptly disconnected and you may lose unsaved work. The session on the host may or may not be closed (depending on the host and application).

Checking the Current Battery Level To check the current battery level: 1. Display a Battery Status window by pressing the Battery icon on the Direct Access Panel, or by pressing <Fn-F2>. 2. The status window has yellow and red regions that correspond to the Low and the Critical warning levels. If the current battery level is in the yellow or red regions, complete your current task and then change the battery. 3. To close the Battery Status window, press the OK button with the pen, or press <Enter>, or wait for the window to disappear by itself.

Figure 5-6. Checking the Battery Level 5-16