Page 94

Terminal Configuration: Building and Sending the Hex Image

Copy Components to the Script Copy files from the File Explorer Window to the Script Window using the drag and drop method with the mouse or the Copy command. To copy files or directories to the script being generated: 1. Click on the File Explorer Window to make it the active window. 2. Click on the source directory in the Directory Tree Pane. TCM displays the directory contents in the Contents Pane. 3. Click on the file(s) and/or directory in File Explorer. Note: Optionally, use the standard Windows Shift+Left-click and Control+Left-click features to select multiple files and directories. 4. Drag and drop the selected file(s) and/or directory from File Explorer to the target directory in the Script Window. OR Click on the target directory and select the File Explorer Copy icon from the toolbar.

Save the Script To save the changes to a new script: 1. From the File menu, choose Save As. OR On the toolbar, click on

.

2. Enter the path and filename. TCM appends a.TCM extension to the script. 3. Choose the OK button. Note: If you save an untitled script, TCM by default saves the script to the directory that the Script Browser is pointing to. To save changes to an existing script: •

From the File menu, choose Save, OR

•

On the toolbar, click

.

7-9

Page 95

PDT 7200 Series Product Reference Guide

Note: If you open and make changes to an existing script, saving the changes writes over the existing script. If you wish to use an original or Symbol-supplied standard script as a base and save the changes in a new script, use Save As instead of Save after making the changes.

Building the Image As part of the build, TCM performs a check on the script which verifies that all files referenced in the script exist. If the image is bootable, TCM verifies that the boot files are available. Note: Performing a check is more important for previously existing scripts to ensure that files referenced in the script are still in the designated locations. To check a script: 1. In the Script Window, select the script. 2. Save the script, if not already saved. 3. From the Script Menu, choose Check. OR On the toolbar, choose

.

4. TCM verifies that files referenced in the script exist on available drives and lists an error message in the Errors found box for any missing files. 5. Choose the OK button to exit. To build a script: 1. In the Script Window, select the script to be built. 2. From the Script menu, select Build. OR

7-10

Page 96

Terminal Configuration: Building and Sending the Hex Image

On the toolbar, choose

. The Configure Build window appears.

3. Select whether to build the partition table, or one volume. 4. Select ASCII format for your hex image, or Compression, which reduces the size of most hex images in order to speed downloading. Click OK. 5. TCM performs a check. If the script is has no errors, TCM proceeds with the build.

If the Build Fails If the build fails, TCM displays a message indicating which file(s) are missing. If the total amount of flash required by the script exceeds the image size, a TCM error results and the build fails. To correct this, reduce the number of files in the volume, or make the disk non-bootable. Refer to Defining Script Properties on page 7-6 for more information on setting the image size appropriately.

7-11

Page 97

PDT 7200 Series Product Reference Guide

Sending the Hex Image Once the hex file is built, you are ready to download it to the terminal. A Hex image download requires both TCM and a program loader stored on the terminal. The terminal comes with a program loading utility, Initial Program Loader (IPL), stored in the terminal’s write-protected flash. To run IPL, the terminal must be inserted in a cradle or connected to a host PC by direct serial connection.

Loading the BIOS Uploading a new BIOS erases only the 128K of Flash where BIOS is stored. While IPL is updating the BIOS, the BIOS image is saved in memory until the entire BIOS is received and verified. The Flash Disk image and application storage area are unaffected.

Saving the Script If you made changes to the script since last saving it, save the script again.

Connect The Terminal and Development PC To send the hex file to the terminal, first link the terminal and development PC by one of the following devices: •

Direct serial link

•

Cradle (refer to Chapter 3, Cradle Setup and Operation in the Product Reference Guide for more information on setting up the cradle).

Begin the Send in TCM In TCM on the PC: 1. Select the script. 2. From the file menu, choose Load Terminal. OR

7-12

Page 98

Terminal Configuration: Building and Sending the Hex Image

On the toolbar, choose

. The Load Terminal screen displays.

3. If the correct hex file is not displayed in the Hex File to field, click on the browse button and navigate to the correct hex file to be downloaded. 4. Click on the Comm Port pull-down menu and select the COM port being used. Ports already in use display in the Unavailable Ports field. 5. Click on the Baud Rate pull-down menu and select the appropriate baud rate. Your options are 2400, 4800, 9600, 19200,38400, 57600, 115200. 6. Click on the Protocol pull-down menu and select the appropriate protocol. Your options are: RTS/CTS and XON/XOFF. You may now return to the Product Reference Guide for information on running the terminal’s Initial Program Loader (IPL).

7-13

Page 99

PDT 7200 Series Product Reference Guide

Initial Program Loader (IPL) Initial Program Loader (IPL) is a small utility program that is built into each terminal. The purpose of IPL is to verify the flash contents prior to a cold boot of the system, and to provide a simple method of updating the flash contents via the serial port or cradle. The images that IPL can accept are in the form of “hex” files” that contain not only the data to be downloaded to the terminal, but also sufficient extra information to ensure that each hex file contains an image for a single partition. Hex files for standard system components such as the BIOS and Setup are provided by Symbol. Hex files for custom components, such as disk images or custom partition maps are built on a PC using the TCM program. IPL is only capable of loading whole partitions (it cannot update individual files in a disk image).

Using the Keyboard Operation of the IPL is controlled by the keyboard. IPL recognizes the following keys: •

Cursor Up

•

Cursor Down

•

Enter or Trigger

•

Backlight

•

Lighter

•

Darker

The effects of these keys are as follows: Cursor Up/Down

Whenever these keys are pressed in a menu screen, they cause the previous/next item in the menu to be highlighted. Moving off the end of a menu causes a wrap to the other end of the menu list. If the menu is longer than the screen is deep, then screen will automatically scroll up or down to keep the highlighted item visible on the screen.

Enter or Trigger

Whenever this key is pressed in a menu screen, the currently highlighted item is selected, and IPL advances to the next screen. If the system supports more than one trigger, then any of the triggers can be used as the Enter key.

Backlight

Pressing this key toggles the backlight (if present) between on and off. This key is always active (even if IPL is not in a menu screen).

Lighter/Darker

Each press of these keys adjusts the screen contrast up or down. The keys are always active (even if IPL is not in a menu screen).

7-14

Page 100

Terminal Configuration: Building and Sending the Hex Image

Using the Touch Screen If the system supports a touch screen, then the touch screen can be used instead of the keyboard to control IPL. Cursor Up/Down

Touching the screen on the up or down arrows on the screen is exactly the same as using the Cursor Up/Down keys on the keyboard.

Enter

Touching the bottom of the screen exactly the same as pressing the Enter key on the keyboard.

Backlight

This can only be controlled from the touch screen on the 7200. Each tap on the backlight control area of the 7200 screen will toggle the backlight (if present) between on and off.

Contrast

The screen contrast can only be adjusted by the touch screen on the 7200. Tapping the contrast control area on the 7200 screen increases the screen contrast by one step with each tap. Continually pressing the contrast control area on the 7200 screen decreases the contrast at a rate of approximately five steps per second.

Invoking IPL To deliberately invoke the IPL, hold the trigger while performing a cold boot by pressing and holding the Power Icon for the required amount of time. If the trigger is pressed when the terminal is reset, then control is passed to IPL instead of to the BIOS. If the trigger is not pressed, then IPL verifies all mandatory partitions to ensure that they are present, and verifies the checksum on all checksummed partitions (IPL, Partition Map, BIOS, and Setup). If any of these partitions is missing or corrupted, then control is automatically passed to IPL instead of the BIOS, so that the corrupted data can be reloaded before it causes any problems. If IPL is invoked accidentally, then either reset the terminal again without holding the trigger, or select Run System option in the baud rate menu. When IPL is invoked (by cold booting while pressing the trigger, or by detecting a corrupt flash partition), IPL sounds the beeper to indicate that IPL has been invoked, and displays the Copyright Screen.

7-15

Page 101

PDT 7200 Series Product Reference Guide

The terminal displays the copyright screen for three seconds. During this time, IPL is verifying the Partition Map and the mandatory and checksummed partitions. Elan IPLVer. 1.0 Copyright 95-99 Symbol Tech. Flash Type 0810a

The version number on the top of the screen identifies the version of IPL you are using. The flash type at the bottom of the screen identifies the size and type of flash chip installed in the terminal, which you need for your TCM script generation. See Defining Script Properties on page 7-6. Pressing the Enter key while the copyright screen is displayed advances the program to the Baud Rate Menu. Baud Rate Run System 2400 4800 9600 19200 38400 57600 115200

1. Use the up and down cursor keys, or tap the arrows on the touch screen to scroll to the appropriate baud rate. IPL supports baud rates from 2400 to 115200 baud. (default is 115200 baud) 2. Press the Enter key or the Scan key to accept the selected baud rate. Note: If IPL is selected accidentally, or the IPL session is complete, you may select “Run System” from this menu to exit IPL an boot the system. The only other way to exit IPL manually is to hold the Power

7-16