Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 16

PDT 6800 Series Product Reference Guide: Chapter 6 Maintaining the Terminal

Pages 66 to 73 of 139, from PDT 6800 Series Product Reference Guide

The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol PDT-6800, Symbol PDT-6810, Symbol PDT-6842 and Symbol PDT-6846

Page 66

Chapter 6 Maintaining the Terminal Batteries The PDT 6800 Series terminal is powered by a rechargeable Nickel Cadmium (NiCd) or Lithium Ion battery pack. Fully charged, the battery pack provides up to 8 hours of continuous operation. The NiCd battery pack is charged by: !

placing a terminal with the battery installed in a CCM 38/6860, CRD 38/6865, or CRD 38/6866 cradle for 7 hours, or

!

connecting the terminal to a PC Adapter, or

!

placing the battery pack in a spare battery charging slot on the CCM 38/6860 or CRD 38/6865 for up to 7 hours. Note: The terminal can be used while the battery is being charged in the CCM 38/6860 or connected to the PC Adapter.

The Lithium Ion battery pack p/n 21-40340-01 is charged by removing the battery from the terminal and charging in a UBC 2000 battery adapter p/n 21-32665-24. Refer to the UBC 2000 Quick Reference Guide for more information.

6-1

Page 67

PDT 6800 Series Product Reference Guide

Battery Life Battery life is affected by many factors, including !

scanning

!

radio communications

!

very high or very low operating temperatures

!

backlighting use

!

battery age.

When to Replace or Recharge the Battery The PDT 6800 Series terminals provide two types of indicators to notify you when battery power is running low: warning messages and modified cursors. These indicators may be changed or disabled by an application. !

LOW BATTERY - When the battery is low, the cursor changes as shown in Table 61 on page 6-2. If ERR3000 is loaded, the message LOW BATTERY also appears. At this level the terminal continues to operate, but there is probably less than 1 hour of usable power left.

!

VERY LOW - When the power is very low, the DEAD BATTERY message appears and the system powers off. Replace or recharge the battery pack before attempting to use the terminal. If the battery is not immediately recharged or replaced, data may be lost. Table 6-1. Cursor Indicators Keyboard State

Low Battery

Unshifted

(inverted caret)

(inverted solid caret)

Shifted

(caret)

(solid caret)

Momentary Shifted

(up arrow)

(solid up arrow)

Momentary Unshifted

(down arrow)

(solid down arrow)

(underline c)

(inverse c)

(underlined f)

(inverse f)

Control Function

6-2

Cursor Character c f

Page 68

Maintaining the Terminal

Backup Batteries To prevent data loss during battery replacement, the terminal utilizes a super cap as a backup. The super cap provides sufficient power to preserve memory contents for approximately 15 minutes while the primary battery is replaced. The super cap does not provide enough power to operate the terminal. On receiving a low battery message, replace or recharge the primary battery immediately.

Replacing the Battery Pack Battery packs available from Symbol are listed below. System

P/N

Battery Pack

NiCd Six-cell, 600 mAh IS

21-36474-01

Intrinsically safe rechargeable in CCM 38/6860, CRD 38/ 6865, CRD 38/6866, and PC adapter

Lithium Ion

21-40340-01

Rechargeable in UBC 2000 battery adapter p/n 21-3266524

Note: The Series 3800 NiCd battery packs, 3872-103, 3872-105, and 3872115, CANNOT be used in the Series 6800 terminal.

Removing the Battery Pack To remove the battery pack (Figure 6-1): 1. Power the terminal off. 2. Press the battery release buttons on both sides of the handle.

6-3

Page 69

PDT 6800 Series Product Reference Guide

3. Slide the battery pack out of the handle.

Battery Compartment Press Release Button

Press Release Button Battery Pack

Figure 6-1. Removing the Battery Pack If you intend to store your terminal without the battery pack, ensure that you have stored any data and/or programs you wish to keep on another terminal, a host computer, or another medium to avoid loss of data. The terminal backup power source retains data for approximately 15 minutes after the battery pack is removed, as long as the backup batteries remain in place.

Installing the Battery Pack 1. Orient the battery pack with the handle facing the terminal’s scan window (Figure 6-2). 2. Slide the pack into the battery compartment while pressing the battery release buttons. 3. Press the battery lock in to secure.

6-4

Page 70

Maintaining the Terminal

Push to Lock Orient

Slide

Figure 6-2. Installing the Battery Pack

Battery Charging Tips For maximum capacity and battery life, follow these helpful hints:

Do !

Charge at temperatures between 0°C and 38°C (32°F to 100°F); 21°C (70°F) is preferred

!

Recharge as soon as you see the “Low Battery” message

!

Save your data and program on another terminal or another medium if you plan to store your terminal without the primary battery pack

!

Store batteries at room temperature of 21°C (70°F) or cooler

!

Recharge the NiCd battery pack after storage.

Don't !

Store or recharge primary batteries at temperatures below 0°C (32°F) or above 38°C (100°F)

!

Judge a battery's charge level by measuring its voltage; voltage does not indicate charge level. 6-5

Page 71

PDT 6800 Series Product Reference Guide

Charging the NiCd Battery Pack The NiCd battery pack automatically charges when the terminal is placed in a cradle or connected to a PC Adapter. A full charge takes about 7 hours. We recommend that you always keep the NiCd battery pack fully charged.

Charging NiCd Battery pack in the Terminal Using a Cradle To charge a NiCd battery in the terminal, using the CCM 38/6860, CRD 38/6865, or CRD 38/6866 cradle (Figure 6-3): 1. Place the terminal in the cradle. The cradle charging light flashes when charging a discharged battery and remains steady when trickle-charging a charged battery.

CCM 38/6860

CRD 38/6865

CRD 38/6866

Figure 6-3. Charging the Battery in the Cradle 2. Leave the terminal up to 7 hours to recharge a fully discharged battery.

Charging NiCd Battery Packs Outside the Terminal Slots are provided in the CCM 38/6860 and CRD 38/6865 cradles to charge spare battery packs outside the terminal. Place the battery pack to be charged in one of the battery slots in the cradle. The LED indicator lamp under the battery slot in which the terminal was placed indicates the battery is charging. (On the CCM 38/6860, the spare-battery-charging indicator lamp is on the right.) If the lamp is off, the battery pack is not charging. A blinking LED indicates fast charge; a solid on LED means slow charge/ready. See the cradle documentation listed in Related Publications on page x for details.

6-6

Page 72

Maintaining the Terminal

Caution The optional communications cradles are NOT certified for use in potentially hazardous environments. To charge an intrinsically safe PDT 6800 Series terminal in a cradle, remove the terminal from the potentially hazardous environment before charging.

Battery Charging with the PC Adapter Refer to Chapter 2, Accessories Setup, for instructions on setting up the PC Adapter for charging. Battery charging begins automatically when power is supplied to the PC Adapter. Fully charging a battery using the PC Adapter requires 7 hours.

Other Charging Options You have the option of charging battery packs in the UBC 1000 or 2000 Charger. Refer to the documentation for the charger for more information.

Charging the Lithium Ion Battery Pack Note: Placing the terminal in the cradle with a Lithium Ion battery installed does not damage the battery. The Lithium Ion battery does not charge when the terminal is placed in a cradle. Use the cradle for communications and as a place holder for the terminal when a lithium Ion battery is installed. To charge the Lithium Ion battery p/n 21-40340-01, remove the battery from the terminal and charge in a UBC 2000 battery adapter p/n 21-32665-24. Refer to the UBC 2000 Quick Reference Guide for more information.

Cleaning The PDT 6800 Series terminals require a minimum amount of maintenance. However, keep the terminal clean to avoid problems and prolong the terminal’s life. Before doing any maintenance or cleaning, power the terminal off.

6-7

Page 73

PDT 6800 Series Product Reference Guide

To clean a terminal, use a clean, soft cloth dampened with a mild cleaner such as soap and water. Do not use abrasive paper, cloth, or abrasive/corrosive cleaners. Wipe the entire terminal, except for the scanner window, with the damp cloth. Clean the charging contacts, keypad, and scanner trigger. Wipe the scanner window periodically with a lens tissue or other material suitable for cleaning optical material such as eyeglasses. Do not pour, spray, or spill any liquid on any part of the terminal, particularly the scanner or scan element components.

Storage If the terminal will not be used for a while, store it in a cool, dry place, away from dust. For the best protection, repack the terminal in the original shipping container for storage.

Caution If you remove the primary battery, the terminal maintains memory contents for at least 15 minutes. To prevent loss of programs and data, transmit them to a host computer before removing the primary batteries for longer than 15 minutes. When you remove the terminal from storage without the battery pack, reset the real time clock. Refer to the Series 3000 Application Programmer’s Reference Manual or Series 3000 Application Programmer’s Guide for specific instructions.

6-8