PDT 6800 Series Product Reference Guide: Chapter 7 Error Recovery and Troubleshooting

Pages 74 to 87 of 139, from PDT 6800 Series Product Reference Guide

The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol PDT-6800, Symbol PDT-6810, Symbol PDT-6842 and Symbol PDT-6846

Page 74

Chapter 7 Error Recovery and Troubleshooting Introduction This chapter provides information to assist in basic troubleshooting analysis and correction, including: !

Error messages

!

Troubleshooting start-up failures

!

Troubleshooting Spectrum24 terminal initialization failures

!

Running the Self Test function

!

Self Test summaries

!

Keyboard test

!

Running memory transfer.

!

Scanning problems

7-1

Page 75

PDT 6800 Series Product Reference Guide

Error Messages If ERR3000 is loaded in the system configuration, the terminal displays the following messages to indicate error conditions that affect system performance. A message is usually accompanied by one or more beeps, after which the system returns to its previous status. The application can change the actual wording of the messages or disable messages. The messages listed in Table 7-1 are representative. Refer to the Series 3000 Application Programmer's Guide or your application guide for additional information. Table 7-1. Error Messages Message

Explanation

Double Key Error

Two or more keys were pressed at the same time. This does not include boot sequences described in Chapter 5, Operating the PDT 6800 Series.

Low Battery

The battery pack should be recharged or replaced as soon as possible.

Dead Battery

Replace or recharge the battery pack immediately. This message is programmable, so it may be worded differently. See your application guide. After this message is displayed, the terminal shuts itself off. You may not be able to power it on again until the battery pack is charged.

Power Fault

The last terminal power off was caused by a power failure. Possible causes of a power failure include: • the battery pack is removed with the terminal on • the terminal is dropped • the batteries lose power suddenly • the terminal displays a low battery power error message, and you attempt to power the terminal on without recharging or replacing the batteries.

7-2

Page 76

Error Recovery and Troubleshooting

Troubleshooting Table 7-2 lists some minor problems, causes, and actions to take. If you cannot resolve the problem after checking this list, call the Symbol Support Center for assistance. Table 7-2.Troubleshooting the Terminal Symptom

Possible Cause

Action

Display is blank.

Battery pack is dead or missing.

Replace or recharge battery pack.

Terminal does not respond when keys are pressed.

Application program was not Repeat downloading. successfully downloaded.

Time and date are incorrect.

Real-time clock has malfunctioned or needs setting.

Set time and date. See your application guide.

Startup Failure Problems are most frequently start-up failures. If cold booting the terminal does not start the application successfully, the application, the system software, or the system is malfunctioning. If you can boot the system to Command Mode, try the following: !

Use Program Loader to download a new version of the software to NVM. This procedure is described in Chapter 3, Batch and Spectrum One Terminal Setup or Chapter 4, Spectrum24 RF Terminal Setup. After downloading new software, warm boot the terminal as described in Chapter 5, Operating the PDT 6800 Series.

!

Use Self Test to check whether system hardware is operational. The Self Test procedure is described later in this chapter. After downloading new software, warm boot the terminal as described in Chapter 5, Operating the PDT 6800 Series.

Boot Failure Messages During a cold boot, the system briefly displays a status line for each driver as it loads, in the format 0:Driver

#.##

The line shows a status value, usually 0, followed by the name and version number of the driver. If the system halts at one of these lines and displays a status value other than 0, the displayed driver did not load properly.

7-3

Page 77

PDT 6800 Series Product Reference Guide

If such a failure occurs, cold boot the terminal again. If this does not solve the problem, call Symbol Customer Support. More troubleshooting information is found in the documentation listed in Related Publications.

Spectrum24 Terminal Typical initialization and operating problems and solutions for Spectrum24 terminals are listed in Table 7-3. Table 7-3.Troubleshooting Spectrum24 Terminal s Problem

7-4

Explanation/Action

Out of range

Terminal is out of the Access Point’s range. If you move the terminal during initialization, the terminal may be out of range of the AP and unable to complete the initialization process. Move back in range and repeat the initialization process.

Startup process fails

Boot server type (BOOTP or DHCP) doesn’t exist. Verify that the boot server is operating and able to respond to TCP/IP, BOOTP, or DHCP requests from the terminal.

Low battery message

Place the terminal in a cradle and recharge battery. OR Power terminal off and replace battery.

Battery is dead

Battery not replaced after receiving low battery message or terminal left on for more than 24 hours. Recharge or replace the battery.

Terminal disassociated from Access Point

Application does not respond to interactive operations. Applications using internal batch mode continue to function until required to transmit via radio, then fail to work. No message displayed.

Page 78

Error Recovery and Troubleshooting

Self Test Function Command mode includes a Self Test function which verifies that terminal hardware components are operating properly. Components tested include: !

Real-time clock (RTC)

!

Battery power

!

Keyboard codes

!

Liquid crystal display (LCD) controller

!

Read-only memory (ROM), random-access memory (RAM), expanded memory (EMS), and non-volatile memory (NVM).

Run Self Test if you suspect a problem with the hardware. Except for keyboard testing, no operator input is necessary after selecting a test screen.

Running Self Test Access the Self Test function from the Command Mode Menu: 1. Boot to Command Mode (refer to Chapter 5, Operating the PDT 6800 Series for boot sequence). 2. In the Command Mode Main Menu, use the UpArrow or DownArrow to scroll through the options. 3. Highlight Self Test and press <Enter>. Press <CLR> in any Self Test screen to return to the Self Test screen, or from the Self Test screen to return to the Command Mode screen.

7-5

Page 79

PDT 6800 Series Product Reference Guide

Self Test Summaries Self test is divided into five functions or screens: Config Screen 1 - Reports the terminal series, BIOS version, battery status, and current power source. Config Screen 2 - Reports information on the keyboard and display, including power wakeup source. Memory Screen - Tests ROM, RAM, and EMS (Expanded) memory, and reports the amount of installed RAM and EMS. Fill Screen - Fills the entire screen with a test pattern to verify that the entire screen displays. Set RTC Screen - Sets the time and date settings of the real-time clock.

Keyboard Test Keyboard testing can be performed while the terminal displays Config Screen 1 results. Test any keys except <CLEAR> and <PWR>. When you press a key, the corresponding key code is displayed on the top row to the right of the test name. Table 7-4 lists the codes for the 35-key keyboard and Table 7-5 lists the codes for the 46-key keyboard.

7-6

Page 80

Error Recovery and Troubleshooting

Table 7-4. 35-Key KeyboardTest Code s Key

Test Code

Key

Test Code

SPACE

00

L

19

ALPHA

01

M

20

CTRL

02

N

21

FUNC

03

O

22

BKSP

04

P

23

SHIFT

07

Q

24

A

08

R

25

B

09

S

26

C

10

T

27

=

11

U

28

E

12

V

29

F

13

W

30

G

14

X

31

H

15

Y

32

I

16

Z

33

J

17

ENTER

34

K

18

7-7

Page 81

PDT 6800 Series Product Reference Guide

Table 7-5. 46-Key KeyboardTest Codes Key

Test Code

Key

Test Code

Key

Test Code

FUNC

01

M

17

Period

32

SHF

02

N

18

Up arrow

33

CTL

03

0

19

Down arrow

34

A

05

P

20

7

35

B

06

Q

21

8

36

C

07

R

22

9

37

D

08

S

23

4

38

E

09

T

24

5

39

F

10

U

25

6

40

G

11

V

26

1

41

H

12

W

27

2

42

I

13

X

28

3

43

J

14

Y

29

0

44

K

15

Z

30

ENTER

45

L

16

BKSP

31

If numbers other than those given in the tables appear on the display, please contact your authorized representative. Press <CLEAR> to terminate the test and return to the Self Test screen.

Memory Transfer Program Command Mode includes a memory transfer utility that transfers data from a terminal to a host PC for program troubleshooting. Programmers can analyze an application using tools provided in the Series 3000 Application Development Kit and described in the Series 3000 Application Programmer’s Reference Manual.

Hardware Setup 1. Turn off the terminal and host PC. Disconnect or unplug the cradle, if used.

7-8

Page 82

Error Recovery and Troubleshooting

Caution Always power off the terminal before attaching or removing cables and adapters. 2. Connect an RS-232 null modem cable to the PC's serial port.

Figure 7-1. MemoryTransfer Connections 3. Connect the other end of the cable to the cradle’s communication port. 4. Connect the cradle to a power source. 5. Place the terminal in the cradle. 6. Power on the host PC.

Set Communications Parameters Host 1. Start the communications program on the host PC. 2. Set up the host communication parameters (these parameters must match the terminal’s parameters). At the DOS prompt on the host, enter: RCVHEX <filename.hex> <baud rate> <comport#>

Typical parameters are: 38400 bps 7 bit data

Odd parity Xon/Xoff flow control

7-9

Page 83

PDT 6800 Series Product Reference Guide

Terminal 1. Boot the terminal to Command Mode (refer to Chapter 5, Operating the PDT 6800 Series for the appropriate key sequence). 2. Select the Memory Transfer function from the Command Mode menu. Use UpArrow or DownArrow to scroll through the Command Mode options until Memory Transfer is displayed, then press <ENTER>. 3. Select the range of memory to transfer by pressing the first letter of the desired range (All, Range, or None), or use the UpArrow or DownArrow and press <ENTER>. If you select All, the program skips to the range verification screen (step 7, page 10). If you select Range, the screen displays: RAM Use Arrow Keys Start End 00000 9FFFF

4. Specify a range of RAM by setting the Start and End addresses. "

Use RightArrow and LeftArrow to move the cursor to the digit to be changed

"

Use UpArrow and DownArrow to change the values.

Type a range and press <ENTER>. 5. Specify a range of NVM to transfer. Choose All or None. 6. If the system has EMS installed, it prompts for the range to transfer; otherwise, it skips this screen: EMS Use arrow keys Start End

The range is specified in page numbers (16 KB per page). Use RightArrow and LeftArrow to move between the Start and End values. Use UpArrow and DownArrow to change the page number value. Set the range and press <ENTER>. 7. The terminal displays a range verification screen. For example: RAM NVM

7-10

0000 D510

3FFF DFFF

Page 84

Error Recovery and Troubleshooting

EMS 0000 010 Correct? <ENT>

If the values are correct, press <ENTER>. If the values are not correct, press <CLEAR> to clear the fields and select new values. 8. Specify the baud rate. Use the UpArrow and DownArrow to scroll through the list of baud rates until the correct rate is displayed and press <ENTER>. Note: Flow control may be necessary at 38400 bps and higher. 9. Specify the data bits. Press <7> or <8>, or use UpArrow and DownArrow to display the values 7 or 8, and press < ENTER>. Note: If you select 8 data bits, the program selects No parity and skips the next screen. 10. Specify parity type. Use UpArrow and DownArrow to display a parity option, or press the first letter of a parity option (Even, Odd, None, Space, or Mark) and press <ENTER>. 11. Set flow control. Use UpArrow and DownArrow to display the flow control options, or press the first letter of an option (None, Xon/Xoff, or RTS/CTS) and press <ENTER>.

Start Communications 1. The terminal is ready to send the data to the host PC and displays: Comm Parameters Start? <ENT>

2. Verify that the host is ready to receive data. 3. Press <ENTER> on the terminal. While data is being transferred, the terminal displays a report of the 1 KB range being transferred: Memory Transfer Sending: XXXX

7-11

Page 85

PDT 6800 Series Product Reference Guide

The display is updated for every 1024 bytes (1 KB) of memory. 4. When the transmission completes or aborts, the terminal displays the transmission status screen: Memory Transfer Status 0000

A status of 0000 (all zeros) indicates that the transfer was successful. Any other status indicates failure. Refer to Appendix C, Communications Status Codes, for the status codes which indicate the source of the error.

End Communications To return to the Command Mode Main Menu, press <CLEAR>. Take whatever corrective action is necessary and reboot the terminal.

Internal Modem Problems If you are having difficulties with your internal modem, please check the following before returning your product: !

Connection to the telephone network is correct.

!

Any necessary special requirements such as dialing 9 and ignoring dial tone have been considered in the event of using a PBX.

!

Firmware settings described in the Series 3000 Application Programmer’s Guide have been configured correctly.

Scanning Problems What If... Nothing happens when you follow the operating instructions? !

Check the system power.

!

Verify that the scanner is programmed to read the symbology you are trying to read.

!

Try scanning a test symbol of the symbology you are trying to read.

!

Check the bar code to ensure that it is not defaced. A defaced bar code may not be readable.

7-12

Page 86

Error Recovery and Troubleshooting

!

Check to see that you are scanning from the proper distance.

Your terminal operates but scanned data is not displayed correctly? !

Check the system power.

!

Check that the communications parameters (baud rate, parity, stop bits, etc.) are set properly for the receiving device.

The laser does not activate? !

You may have exceeded the allowable amount of scanning activity within the limits of your laser class of operation; in this case, wait for a short interval before scanning again.

!

You may be scanning in an inappropriately hot environment. If so, remove the equipment from the environment or allow the laser to cool down.

7-13

Page 87

PDT 6800 Series Product Reference Guide

7-14