Page 90

Appendix C Communications Status Codes Introduction The program loader status code consists of four hexadecimal digits which indicate whether or not the transfer was successful, and if not, the source of the communications error. A status code of 0000 indicates success; any other code indicates failure. Table C-1 lists the failures associated with the status codes. The values are additive.

C-1

Page 91

PDT 6100 Product Reference Guide

Table C-1. Communications Status Codes Status Code

C-2

Meaning

0002

Receive overrun error

0004

Receive parity error

0008

Receive framing error

0010

Programming voltage not present

0020

Data Set Ready or Carrier Detect not detected on open

0040

Lost DSR while receiving

0080

ABORT key hit during comm

0100

Insufficient NVM for image

0200

Illegal Intel hexadecimal record

0400

Unsupported Intel record

0600

NVM EEPROM failed to erase

0800

Receive time-out error

1000

Control start character time-out

2000

Clear To Send inactive time-out error

4000

Receive buffer full

Page 92

Appendix D Specifications Environment The terminal’s operating conditions are listed in Table Table D-1. Table D-1. Environmental Specifications Condition

Range

Operating Temperature

-4° to 122°F

0° to 40°C

Storage Temperature

-40° to 158°F

-40° to 60°C

Humidity (Operating)

5% to 95% non-condensing @ 50°C for 168 hours

Altitude

Up to 10,000 feet

D-1

Page 93

PDT 6100 Product Reference Guide

D-2