Page 90
Appendix C Communications Status Codes Introduction The program loader status code consists of four hexadecimal digits which indicate whether or not the transfer was successful, and if not, the source of the communications error. A status code of 0000 indicates success; any other code indicates failure. Table C-1 lists the failures associated with the status codes. The values are additive.
C-1
Page 91
PDT 6100 Product Reference Guide
Table C-1. Communications Status Codes Status Code
C-2
Meaning
0002
Receive overrun error
0004
Receive parity error
0008
Receive framing error
0010
Programming voltage not present
0020
Data Set Ready or Carrier Detect not detected on open
0040
Lost DSR while receiving
0080
ABORT key hit during comm
0100
Insufficient NVM for image
0200
Illegal Intel hexadecimal record
0400
Unsupported Intel record
0600
NVM EEPROM failed to erase
0800
Receive time-out error
1000
Control start character time-out
2000
Clear To Send inactive time-out error
4000
Receive buffer full
Page 92
Appendix D Specifications Environment The terminal’s operating conditions are listed in Table Table D-1. Table D-1. Environmental Specifications Condition
Range
Operating Temperature
-4° to 122°F
0° to 40°C
Storage Temperature
-40° to 158°F
-40° to 60°C
Humidity (Operating)
5% to 95% non-condensing @ 50°C for 168 hours
Altitude
Up to 10,000 feet
D-1