Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 18

Series 3100/3500 Product Reference Guide: Chapter 4 Operating the Series 3100/3500, pages 74 to 82

Pages 74 to 82 of 170, from Series 3100/3500 Product Reference Guide

The original document is the PDF (2.5 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Symbol PDT-3100, Symbol PDT-3110, Symbol PDT-3140, Symbol PDT-3500, Symbol PDT-3510 and Symbol PDT-3540

Page 74

Series 3100/3500 Product Reference Guide

• The PDF417 bar code symbol has multiple rows, but the raster pattern also has multiple scanning rows. For this reason, do three basic things as you scan (refer to Figure 4-10): 1.

Center the aiming pattern on the bar code, as illustrated before.

2.

Keep the pattern in the same horizontal plane as the bar code.

3/4”

3/4”

Figure 4-10. Orienting Scanning Pattern On PDF417 Bar Code 3.

If the vertical scan pattern is not high enough to cover a “tall” PDF417 symbol, it may be necessary to move the scanner slowly down toward the bottom of the symbol, keeping the beam horizontal to the rows, and then slowly back upward toward the top (refer to Figure 4-11).

Figure 4-11. Moving Scan Pattern Upward and Downward on “Tall” PDF Symbol • The scan beam does not have to be perfectly parallel with the top and bottom of the symbol (up to a 4o tilt will work).

4-28

Page 75

Operating the Series 3100/3500

1-D/PDF417 Scan Element Decode Zones 10

25.4

5

12.7

0

0

5

12.7

8 10

25.4

In.

Cm.

8 6 Integrated Scanner

4 2 2 4 6 Mil

Depth of Field in Inches

6

7.5 Mil 20 Mil Min. Element Width 40 Mil Minimum Element Width

Width of Field in Inches / Centimeters

NOTE: Typical performance at 68o F ( 20o C) on high quality symbols.

55 Mil Minimum Element Width

0 12 0

4

6 12.7

8

10 12 14 16 18 20 22 24 26 28 30 32 25.4 38.1 50.8 63.5 76.2

In. Cm.

Depth of field as a function of minimum element width.

NOTE: Typical performance at 68o F ( 20o C) on high quality symbols. Y-module dimension = 3 X. Integrated Scanner

Depth of Field in Inches

5

12.7

2.5

6.4

0

0

2.5

6.4

5

12.7

6.6 Mil 10 Mil Minimum Element Width

In. Cm.

15 Mil Minimum Element Width

0 1 2 0 2.5 5.1

4 10.1

6 15.2

8 20.3

10 25.4

12 30.5

14 35.6

Width of Field in Inches / Centimeters

Figure 4-12. 1-D/PDF417 Scan Element 1-D Decode Zone

In. Cm.

Depth of field as a function of minimum element width.

Figure 4-13. 1-D/PDF417 Scan Element PDF417 Decode Zone

4-29

Page 76

Series 3100/3500 Product Reference Guide

Figure 4-14. Attaching/Using a Scanner

Attaching a Scanner or Wand To attach a scanner or wand to a terminal: 1.

Power the system off.

2.

Remove the end cap from the top of the terminal.

3.

Plug the scanner into the top of the terminal (refer to Figure 4-14).

4.

Power the terminal on or press the scan trigger to power the terminal on.

5.

To use the scanner or wand, refer to the user documentation provided. Note:

4-30

The <Enter> key is often the default "soft trigger." Applications can designate another key as the "soft trigger." Refer to the Series 3000 Application Programmer's Reference Manual for more information on the STG3000.EXE program.

Page 77

Operating the Series 3100/3500

Communications With a PC 3115 Communications/Charger Adapter An optional communications/charger adapter (CCA) is available for communicating with a host PC when a cradle is not available. Note:

It is not necessary to connect the terminal to a power source for communications.

To connect the 31XX/35XX to a PC using the 3115 CCA: 1.

Plug the 10-pin RJ-41 connector into the base of a Series 31XX/35XX terminal (refer to Figure 4-15).

2.

Plug the DB-25 connector into the host’s communications port.

3.

Start the communications program.

PDT 3100 or PDT 3500

RJ41 3115 CCA

DB25

Power Input Jack

Figure 4-15. Connecting the 3115 CCA for Communications

4-31

Page 78

Series 3100/3500 Product Reference Guide

With a Printer The terminal has two accessories which provide communications with a printer, the 3115 CCA and the passive cable.

3115 CCA To connect the 31XX/35XX to a printer using the 3115 CCA: 1.

Plug the 10-pin RJ-41 connector into the base of a Series 3100/3500 terminal.

2.

Plug the DB-25 connector into the printer’s communications port.

3.

Start the communications program. Note:

The CCA is shipped set for RS-232 communications with a PC. To use the CCA with a printer may require changing the internal communications settings. Refer to the Installation Instructions (P/N 70-11314-XX).

Passive Cable An optional cable is available for connecting the terminal to a printer (Figure 4-16) (P/N 20-11062-03). DB9 Connector to Printer Comm Port

RJ41 Connector to Terminal Serial Port

Figure 4-16. Passive Cable Connectors

4-32

Page 79

Operating the Series 3100/3500

To connect the terminal to a printer: 1.

Plug the passive cable’s 10-pin RJ-41 connector into the Series 31XX/35XX terminal’s serial port.

2.

Plug the DB-9 connector into the communications port on the printer.

3.

Start the communications program.

3115 CCA To connect the terminal to a modem using the 3115 CCA: 1.

Plug the 10-pin RJ-41 connector into the base of a Series 31XX/35XX terminal.

2.

Insert a female-to-male gender changer on the female DB-25 connector before plugging the connector into the modem.

3.

Start the communications program. Note:

The CCA is shipped set for RS-232 communications with a PC. To use the CCA with a modem may require changing the internal communications settings. Refer to the Installation Instructions (P/N 70-11314-XX).

Integrated: Direct Connect (PDT 3100, 3110, 3124 only) If the terminal is equipped with a direct connect modem, connect the modem as follows: 1.

Power the terminal off.

2.

Release the hand strap on the back of the terminal.

3.

Detach the plug covering the modem jack on the back of the terminal

4-33

Page 80

Series 3100/3500 Product Reference Guide

4.

Attach one end of the telephone cable to the modem jack connection (Figure 4-17).

Modem Jack

Figure 4-17. Modem Jack Location 5.

Plug the cable’s other connector into a telephone jack.

6.

Power the terminal back on.

7.

Start the communications program on the host and terminal.

Integrated: Acoustic (PDT 3100, 3110, 3124 only) Some Series 31XX/35XX terminals are equipped with a built-in acoustic modem which allows direct data transmission over a telephone line. If the terminal is equipped with an acoustic modem, connect the modem as follows: 1.

Power the terminal off.

2.

Release the hand strap on the back of the terminal.

3.

Place the telephone mouthpiece against the acoustic coupler.

4-34

Page 81

Operating the Series 3100/3500

4.

Reattach the hand strap, securing the phone to the terminal, as shown in Figure 4-18.

Figure 4-18. Connection for Acoustic Coupler 5.

Power the terminal back on.

6.

Start the communications program on the PC and terminal.

Connecting the Internal Modem Some Series 3100 terminals and cradles use an optional internal modem that communicates at rates of up to 14,400 bps (with v.32 bis data compression). It can be connected directly to a telephone line through the RJ-11 port on the terminal (see Figure 4-17) or on the CRD 3100 (see Figure 4-19)..

PDT

3100

PWR CTL SHF

E

FNC

D

CLR

C J

B I

A H

O

G F

N

LAMP

M

T

L

S

K

LIGH

R DARK

Q

T

Y

X

P W V U SPAC

E F9

BSP Z

9

F8

8

F7

7

F6

F5

F4

6

5

4

F3

3

F2

F1

2

1

=

ENTE

F10

R

0

RJ-11 Connector

COMM

RGING

CHA

Figure 4-19. Internal Modem Connector: CRD 3100 Note:

The four-slot cradle does not have an internal modem.

4-35

Page 82

Series 3100/3500 Product Reference Guide

To connect the internal modem: 1.

Connect the phone cord into the RJ-11 port on the back of the terminal or cradle.

2.

Connect the other end of the phone cord into the wall phone jack.

Caution When connecting the internal modem to the phone line, always connect the phone line to the terminal or cradle first, then to the wall phone jack. When removing the connection, always remove the telephone line from the wall phone jack, then remove from the terminal or cradle. There are specific firmware settings which are used to configure the modem’s hardware and software for proper operation and regulatory compliance. The terminal’s application can control these settings and enable you to view and amend the settings for country/region, pulse/tone dialing, or repeat dial timing. Incorrectly defining these settings can lead to illegal use of the modem and can create unreliable operation. The application developer should consult the Series 3000 Application Programmer’s Reference Manual for correct settings.

Connecting to the Telephone Network A compliant telephone cord is required with an RJ-11 plug connection to the modem, terminated with an appropriate and correctly wired local telecom connector compatible with the telephone network. Such a cable may be obtained from your local supplier. Alternately, compliant RJ-11 plugs to RJ-11 plug cables may be used with a range of adapters for locations such as Europe.

4-36